Wall Panel and Trim
Animated publication
Wall Panel and Trim Sections & Details
All details downloadable in .dwg and .pdf
Table of Contents
Wall Panel Details AP Wall Details CS Wall Details AP Panel Openings AP Metal Bldg Walkdoor-KD-Others AP Metal Bldg Walkdoor-PA-SF AP OHD or 3-Sided Opening AP Window by Chief
AP Window or 4-Sided Opening w Jamb Trim–JT AP Window or 4-Sided Opening w Sill Flashing–WFS AP Window or 4-Sided Opening w Trim Only CS Panel Openings CS Metal Bldg Walkdoor-KD-Others CS Metal Bldg Walkdoor-PA-SF CS OHD or 3-Sided Opening CS Window by Chief CS Window or 4-Sided Opening w Jamb Trim-JT CS Window or 4-Sided Opening w Sill Flashing-WFS CS Trim Only 4-Sided Opening w Jamb Trim-JT CS Trim Only 4-Sided Opening w Sill Flashing-WFS Wainscot - Lapped T19.Wainscot Lapped at Zee w A-20
T21.Wainscot Lapped HRC T22.Wainscot Lapped Zee Wainscot Lapped at Sill
Wainscot Lapped Mid-wall at Cee Wainscot Lapped Mid-wall at Zee Wainscot - No Lap (w WTT Trim)
T15.Wainscot No Lap WTT at Cee T17.Wainscot No Lap WTT at HRC T18.Wainscot No Lap WTT at Zee Wainscot No Lap WTT at Sill w Window by Chief
Wainscot No Lap WTT Mid-Wall at Cee Wainscot No Lap WTT Mid-Wall at Zee Base Conditions Base Trim NONE-Lap
Base Trim NONE-No Lap Base Trim NONE-Notch Base Trim Simple L BT-Lap Base Trim Simple L BT-No Lap
Table of Contents
Base Trim Simple L BT-Notch Base Trim w Drip Edge BTN-Lap Base Trim w Drip Edge BTN-No Lap Base Trim w Drip Edge BTN-Notch
Base Trim w Drip Edge Vertical BTNV-Lap Base Trim w Drip Edge Vertical BTNV-No Lap Base Trim w Drip Edge Vertical BTNV-Notch Base Trim w Return Leg BTM-Lap Base Trim w Return Leg BTM-No Lap Base Trim One Piece OPB Wallite Light Transmitting Panel
AP Wall AP Light Transmitting Panel w AP Liner Panel Horizontal Section AP Wall AP Light Transmitting Panel w CS Liner Panel Horizontal Section AP Wall CS Light Transmitting Panel w AP Liner Panel Horizontal Section AP Wall CS Light Transmitting Panel w CS Liner Panel Horizontal Section AP Wall CS Light Transmitting Panel w Full Height Liner CS Wall CS Light Transmitting Panel w AP Liner Panel Horizontal Section CS Wall CS Light Transmitting Panel w CS Liner Panel Horizontal Section CS Wall-CS Light Transmitting Panel or AP Wall-AP LTP w Full Height Liner
Wall Panel Details
Wall Panel Details
AP Wall Details
AP WALL PANEL - The details shown below are typical Chief metal building details. Not all details may apply. Specific details for additional features will be provided for complete installation instructions.
12"
NOTES: · The structural system must be plumb and square prior to panel installation. · Care must be taken to insure panel modularity due to accessory locations and trim. · Insulation has not been shown for clarity. · Blanket insulation must be trimmed above the bottom of panel to prevent water from "WICKING" into the insulation. · Provide air gap of 1/4” min. at bottom of panel to avoid corrosion. · #12-14 X 1 1/4" Fastener spacing is (12" C.C.) unless otherwise noted. ** #12-14 X 1-1/4", Blanket Insulation <=4" thickness ** #12-14 X 2", Blanket Insulation >4" thickness · When possible, CHIEF recommends installing panel so that panel lap is away from prevailing weather.
Top of wall panel is held down 1" from eave height. (Except MSC 2" offset clip, the dimension is 0")
STEEL LINE
BL
GIRT
Clip offset
RAKE ANGLE
WALL PANEL
TAPE MASTIC AT SIDELAPS, IF ORDERED ** #12-14 X 1 1/4 (12" C.C.)
**#12-14 X 1 1/4" (12" C.C.)
TOP OF PURLIN
NOTE: Field cut ends of wall panels above roof line as required on slopes greater than 1 1/4:12.
**#12-14 X 1 1/4" (12" C.C.)
1"
BL
AP PANELING
Intermediate Girt Detail
STEEL LINE
Eave Height
BL
EAVE STRUT
WALL PANEL
BL
PANEL SIDELAP EAVE STRUT
Sidewall Eave Detail Low side shown. High Side Typical.
** #12-14 X 1 1/4" (12" C.C.) (TYP.)
GIRT
12" (TYP.)
RISE
3" 3"
6"
MIN.
**#12-14 X 1 1/4" (12" C.C.)
WALL PANEL
BL
Panel Endlap Detail
* 1/4-14 X 7/8" (TYP.)
AP PANEL FASTENER INSTALLATION
AP PANEL AT GABLE END
1/4-14 X 7/8" (TYP.) (18" C.C.)
NOTE: · Sidelap holes (7/32" DIA.) must be Pre-drilled in the overlapping corrugation only. · The overlapping corrugation does not have the return leg.
NOTES: ·
Field cut panel if required for corner trim.
· Corner Angle connection/fasteners, refer to Girt Corner Detail.
GIRT
12" (TYP.)
SHEETING SUPPORT (SSP)
TAPE MASTIC CENTERED ON HIGH RIB IS SHOWN THOUGH IS AN ORDER OPTION. REFER TO WALL MASTIC REQUIREMENTS IN ORDERED OPTIONS ON DRAWING COVER PAGE (C1)
1/4-14 X 7/8" (18" C.C.)
** #12-14 X 1 1/4" (12" C.C.) (TYP.)
STEEL LINE
CORNER TRIM (CTA)
RETURN LEG
L
B
* 18" (TYP.)
CORNER ANGLE (A-20)
PRE-DRILL PILOT HOLE IN OVERLAPPING PANEL (SEE NOTE)
12" (TYP.)
AP PANEL 1/4-14 X 7/8" (12" C.C.) (TYP.)
** #12-14 X 1 1/4" (12" C.C.) (TYP.)
2 1/2"
2 1/2"
1 1/2"
BASE MEMBER
TAPE MASTIC AT SIDELAPS, IF ORDERED
B
L
AP PANEL INSTALLATION
AP PANEL SIDE LAPS
AP PANEL STANDARD CORNER CONDITION
CS Wall Details
CS WALL PANEL - The details shown below are typical Chief metal building details. Not all details may apply. Specific details for additional features will be provided for complete installation instructions.
6"
3"
NOTES: · The structural system must be plumb and square prior to panel installation. · Care must be taken to insure panel modularity due to accessory locations and trim. · Insulation has not been shown for clarity. · Blanket insulation must be trimmed above the bottom of panel to prevent water from "WICKING" into the insulation. · Provide air gap of 1/4” min. at bottom of panel to avoid corrosion. · #12-14 X 1 1/4" Fastener spacing is (12" C.C.) unless otherwise noted. ** #12-14 X 1-1/4", Blanket Insulation <=4" thickness ** #12-14 X 2", Blanket Insulation >4" thickness · When possible, CHIEF recommends installing panel so that panel lap is away from prevailing weather.
Top of wall panel is held down 1" from eave height. (Except MSC 2" offset clip, the dimension is 0")
STEEL LINE
GIRT
Clip offset
WALL PANEL
RAKE ANGLE
TAPE MASTIC AT SIDELAPS, IF ORDERED ** #12-14 X 1 1/4 (6" C.C.)
**#12-14 X 1 1/4" (12" C.C.)
TOP OF PURLIN
NOTE: Field cut ends of wall panels above roof line as required on slopes greater than 1 1/4:12.
**#12-14 X 1 1/4" (6" C.C.)
1"
BL
CS PANELING
Intermediate Girt Detail
STEEL LINE
Eave Height
EAVE STRUT
WALL PANEL
BL
PANEL SIDELAP EAVE STRUT
Sidewall Eave Detail Low side shown. High Side Typical.
GIRT
6" (TYP.)
3"
** #12-14 X 1 1/4" (6" C.C.) (TYP.)
RISE
3" 3"
6"
MIN.
**#12-14 X 1 1/4" (6" C.C.)
WALL PANEL
BL
1/4-14 X 7/8" (TYP.) (18" C.C.)
Panel Endlap Detail
* 1/4-14 X 7/8" (TYP.)
CS PANEL FASTENER INSTALLATION
CS PANEL AT GABLE END
NOTE: · Sidelap holes (7/32" DIA.) must be Pre-drilled in the overlapping corrugation only. · The overlapping corrugation does not have the return leg.
NOTES: ·
Field cut panel if required for corner trim.
· Corner Angle connection/fasteners, refer to Girt Corner Detail. · Connection of panel to structure at corner is by the corner trim fasteners.
GIRT
12" (TYP.)
** #12-14 X 1 1/4" (12" C.C.) (TYP.)
1/4-14 X 7/8" (18" C.C.)
CORNER TRIM (CT)
STEEL LINE
CORNER ANGLE (A-20)
RETURN LEG
PRE-DRILL PILOT HOLE IN OVERLAPPING PANEL (SEE NOTE)
* 18" (TYP.)
L
B
TAPE MASTIC CENTERED ON HIGH RIB IS SHOWN THOUGH IS AN ORDER OPTION. REFER TO WALL MASTIC REQUIREMENTS IN ORDERED OPTIONS ON DRAWING COVER PAGE (C1)
6" (TYP.)
3"
CS PANEL
* 1/4-14 X 7/8" (TYP.)
** #12-14 X 1 1/4" (6" C.C.) (TYP.)
2 1/2"
1 1/2"
#12-14 X 1 1/4 (12" C.C.) (TYP.)
BASE MEMBER
B
L
CS PANEL INSTALLATION
CS PANEL SIDE LAPS
CS PANEL STANDARD CORNER CONDITION
AP Panel Openings
AP Panel Openings
AP Metal Bldg Walkdoor-KD-Others
AP Panel - Metal Building Walkdoor -- Knocked-Down (by Chief) or Door Not by Chief Refer to Order Documents for Doors by Chief
#12-14 X 1" PANCAKE HEAD FASTENER (36" C.C.)
**#12-14 X 1 1/4" (12" C.C.) INSIDE CLOSURE WALL PANEL
BL
ZEE GIRT
SPECIAL PLATE. REFER TO FRAMING PLANS FOR PIECE MARK (PL)
1/8" X 3/8" BLIND RIVET (7'-0" C.C.)
1/8" X 3/8" BLIND RIVET (3'-0" C.C.) TYP.
HEADER TRIM WITH TROUGH (HTT)
LINER COVER TRIM (LCT1)
1
4 "
1
2 "
LINER COVER TRIM (LCT2)
DOOR FRAME
1
4 "
OPENING HEIGHT
CEE HEADER
1
2 "
Provide air gap of 1/4" min. at bottom of panel to avoid corrosion.
WALKDOOR HEADER TRIM DETAILS
LINER COVER TRIM (LCT1) 1/8" X 3/8" BLIND RIVET (7'-0" C.C.)
Notes: · Hold trims 1/8" back from Walk Door Frame edge (Applies only to walk doors). · Drill Ø1/8" holes for Blind Rivets. · Rivets spaced at 7'-0" C.C. are temporary fasteners. · ** #12-14 X 1-1/4", Blanket Insulation <=4" thickness. · ** #12-14 X 2", Blanket Insulation >4" thickness. · LCT1 or LCT2 used with Liner/Backer. Refer to Liner or Partition Panel Dwg.
JAMB
OPENING WIDTH
4 1/4"
HEADER TRIM WITH TROUGH (HTT)
LINER COVER TRIM (LCT2) (AS REQUIRED)
**#12-14 X 1 1/4" (12" C.C.)
DOOR FRAME
NOTCH WALL PANEL FOR EXTENSION OF TRIM
DOOR FRAME DOOR FRAME
BL
JAMB TRIM (JTA)
WALL PANEL
1/8"
SHEETING SUPPORT (SSP)
JAMB TRIM (JTA)
1/4-14 X 7/8" (12" C.C.)
1/8"
TRIM DETAIL AT CORNER
WALKDOOR JAMB TRIM DETAILS
AP Metal Bldg Walkdoor-PA-SF
AP Panel- Metal Building Walkdoor - Pre-Assembled (by Chief) or Self-Framing Not by Chief Refer to Order Documents for Doors Supplied by Chief
#12-14 X 1" PANCAKE HEAD FASTENER (36" C.C.)
**#12-14 X 1 1/4" (12" C.C.) INSIDE CLOSURE
BL
WALL PANEL HEADER TRIM WITH TROUGH (HTT) 1/8" X 3/8" BLIND RIVET (7'-0" C.C.)
ZEE GIRT
SPECIAL PLATE. REFER TO FRAMING PLANS FOR PIECE MARK (PL)
LINER COVER TRIM (LCT1 OR LCT2) (Field modify as req'd) 1/8" X 3/8" BLIND RIVET (7'-0" C.C.)
1
4 "
1
2 "
DOOR FRAME
1
4 "
OPENING HEIGHT
CEE HEADER
1
2 "
Provide air gap of 1/4" min. at bottom of panel to avoid corrosion.
PRE-ASSEMBLED OR SELF-FRAMING WALKDOOR HEADER TRIM DETAILS
Notes: · Hold trims 1/8" back from Walk Door Frame edge (Applies only to walk doors). · Drill Ø1/8" holes for Blind Rivets. · Rivets spaced at 7'-0" C.C. are temporary fasteners. · ** #12-14 X 1-1/4", Blanket Insulation <=4" thickness. · ** #12-14 X 2", Blanket Insulation >4" thickness. · LCT1 or LCT2 used with Liner/Backer. Refer to Liner or Partition Panel Dwg.
LINER COVER TRIM (LCT1 OR LCT2) (Field modify as req'd)
DOOR SUB FRAME
1/8" X 3/8" BLIND RIVET (7'-0" C.C.)
4 1/4"
HEADER TRIM WITH TROUGH (HTT)
**#12-14 X 1 1/4" (12" C.C.)
DOOR FRAME
DOOR FRAME
NOTCH WALL PANEL FOR EXTENSION OF TRIM.
BL
JAMB TRIM (JTA)
DOOR FRAME
WALL PANEL
1/8"
SHEETING SUPPORT (SSP) 1/4-14 X 7/8" (12" C.C.)
JAMB TRIM (JTA)
1/8"
TRIM DETAIL AT CORNER
PRE-ASSEMBLED OR SELF-FRAMING WALKDOOR JAMB TRIM DETAILS
AP OHD or 3-Sided Opening
AP Panel - OHD or 3-Sided Opening
1/8" X 3/8" BLIND RIVET (7'-0" C.C.) (TYP.) HEADER
BL
WALL PANEL
BL
**#12-14 X 1 1/4" (12" C.C.)
1/8" X 3/8" BLIND RIVET, 18" C.C. WITH DOOR TRIM (DT)
HEADER TRIM WITH TROUGH (HTT) DOOR TRIM (DT) (OPTIONAL) REFER TO PANEL DRAWINGS
HEADER
INSIDE CLOSURE
Provide air gap of 1/4" min. at bottom of panel to avoid corrosion.
DETAILS AT HEADER
1
4 "
JAMB
DOOR TRIM (DT) (OPTIONAL) REFER TO PANEL DRAWINGS
HEADER TRIM WITH TROUGH (HTT) DOOR TRIM (DT) (OPTIONAL) REFER TO PANEL DRAWINGS
1/8" X 3/8" BLIND RIVET, 18" C.C. WITH DOOR TRIM (DT)
OPENING HEIGHT
BL
JAMB TRIM (JTA)
1/8" X 3/8" BLIND RIVET (7'-0" C.C.)
DETAILS AT JAMB
TRIM DETAILS AT HEADER
Notes: ·
Drill Ø1/8" holes for Blind Rivets.
· Rivets spaced at 7'-0" C.C. are temporary fasteners. · ** #12-14 X 1-1/4", Blanket Insulation <=4" thickness. · ** #12-14 X 2", Blanket Insulation >4" thickness.
DOOR TRIM (DT) (OPTIONAL) REFER TO PANEL DRAWINGS
4 1/4"
JAMB
OPENING WIDTH
2 1/4"
HEADER TRIM WITH TROUGH (HTT)
NOTCH WALL PANEL FOR EXTENSION OF TRIM.
**#12-14 X 1 1/4" (12" C.C.)
BL
JAMB TRIM (JTA)
JAMB TRIM (JTA)
WALL PANEL 1/4-14 X 7/8" (12" C.C.)
SHEETING SUPPORT (SSP)
TRIM DETAIL AT CORNER
TRIM DETAILS AT JAMBS
AP Window by Chief
AP Panel - Window by Chief
#12-14 X 1" PANCAKE HEAD (36" C.C.) (TYP.) **#12-14 X 1 1/4" (12" C.C.) INSIDE CLOSURE WALL PANEL HEADER TRIM WITH TROUGH (HTT)
Notes: ·
ZEE GIRT
Drill Ø1/8" holes for Blind Rivets. Drill Ø3/16" holes for Bulbtite Rivets.
BL
·
· Rivets spaced at 7'-0" C.C. are temporary fasteners. · ** #12-14 X 1-1/4", Blanket Insulation <=4" thickness. · ** #12-14 X 2", Blanket Insulation >4" thickness. · LCT1 or LCT2 used with Liner/Backer. Refer to Liner or Partition Panel Dwg.
4 1/4"
1/8" X 3/8" BLIND RIVET (7'-0" C.C.)
1
4 "
HEADER TRIM WITH TROUGH (HTT)
1/8" X 3/8" BLIND RIVET (7'-0" C.C.) (TYP.)
NOTCH WALL PANEL FOR EXTENSION OF TRIM.
OPENING HEIGHT
SPECIAL PLATE. REFER TO FRAMING PLANS FOR PIECE MARK (PL)
JAMB TRIM (JTA)
LINER COVER TRIM (LCT2)
JAMB TRIM (JT)
Provide air gap of 1/4" min. at bottom of panel to avoid corrosion. 1 4 "
WINDOW BY CHIEF
LINER COVER TRIM (LCT1)
4 1/4"
CEE HEADER
CHIEF WINDOW HEADER TRIM DETAILS
TRIM DETAIL AT CORNER
1/8" X 3/8" BLIND RIVET (7'-0" C.C.)
SPECIAL PLATE. REFER TO FRAMING PLANS FOR PIECE MARK (PL)
BL
JAMB
WINDOW BY CHIEF
LINER COVER TRIM (LCT1)
LINER COVER TRIM (LCT2)
OPENING WIDTH
2 1/4"
LINER COVER TRIM (LCT1)
JAMB TRIM (JT)
OPENING HEIGHT
LINER COVER TRIM (LCT2)
**#12-14 X 1 1/4" (12" C.C.)
INSIDE CLOSURE **#12-14 X 1 1/4" (12" C.C.) WALL PANEL
BL
WINDOW BY CHIEF
GIRT #12-14 X 1" PANCAKE HEAD (36" C.C.) (TYP.) 1/8" X 3/8" BLIND RIVET (7'-0" C.C.) (TYP.)
WALL PANEL
URETHANE CAULK (NOT BY CHIEF)
1/4-14 X 7/8" (12" C.C.)
JAMB TRIM (JTA)
3/16" BULBTITE RIVET (12" C.C.) (SIDE ONLY) SHEETING SUPPORT (SSP)
OPENING HEIGHT
CEE SILL
CHIEF WINDOW JAMB TRIM DETAILS
CHIEF WINDOW SILL TRIM DETAILS
AP Window or 4-Sided Opening w Jamb Trim–JT
AP Panel - Window Not by Chief or 4-Sided Opening with Jamb Trim – JT
Notes: ·
LINER COVER TRIM (LCT1)
Drill Ø1/8" holes for Blind Rivets.
· Rivets spaced at 7'-0" C.C. are temporary fasteners. · ** #12-14 X 1-1/4", Blanket Insulation <=4" thickness. · ** #12-14 X 2", Blanket Insulation >4" thickness. · LCT1 or LCT2 used with Liner/Backer. Refer to Liner or Partition Panel Dwg.
1/8" X 3/8" BLIND RIVET, 7'-0" C.C. WITH LINER COVER TRIM (LCT) JAMB
OPENING WIDTH
**#12-14 X 1 1/4" (12" C.C.)
OPENING WIDTH
2 1/4"
BL
JAMB
LINER COVER TRIM (LCT2)
1/8" X 3/8" BLIND RIVET (7'-0" C.C.)
JAMB TRIM (JTA) SHEETING SUPPORT (SSP) LINER COVER TRIM (LCT2)
JAMB TRIM (JTA)
BL
FRAMED OPENING DETAILS AT JAMB
WALL PANEL 1/4-14 X 7/8" (12" C.C.)
GIRT
1/8" X 3/8" BLIND RIVET (7'-0" C.C.) #12-14 X 1" PANCAKE HEAD (36" C.C.) (TYP.)
BL
TRIM DETAILS AT JAMB
1/8" X 3/8" BLIND RIVET, 7'-0" C.C. WITH LINER COVER TRIM (LCT)
BL
**#12-14 X 1 1/4" (12" C.C.) INSIDE CLOSURE
ZEE GIRT
HEADER TRIM WITH TROUGH (HTT) SPECIAL PLATE. REFER TO FRAMING PLANS FOR PIECE MARK (PL) LINER COVER TRIM (LCT2)
LINER COVER TRIM (LCT1)
SPECIAL PLATE. REFER TO FRAMING PLANS FOR PIECE MARK (PL)
WALL PANEL
OPENING
1
4 "
JAMB TRIM (JT)
HEADER TRIM WITH TROUGH (HTT) LINER COVER TRIM (LCT2)
1/8" x 3/8" BLIND RIVET (7'-0" C.C.)
1
4 "
OPENING HEIGHT
GIRT/SILL
Provide air gap of 1/4" min. at bottom of panel to avoid corrosion.
CEE HEADER
OPENING DETAILS AT HEADER AND SILL
TRIM DETAILS AT HEADER
4 1/4"
BL
LINER COVER TRIM (LCT2)
JAMB TRIM (JT)
OPENING HEIGHT
HEADER TRIM WITH TROUGH (HTT)
NOTCH WALL PANEL FOR EXTENSION OF TRIM.
INSIDE CLOSURE **#12-14 X 1 1/4" (12 "C.C.)
JAMB TRIM (JTA)
JAMB TRIM (JT)
WALL PANEL
4 1/4"
GIRT/SILL
TRIM (JT) DETAILS AT SILL
TRIM DETAIL AT CORNER
AP Window or 4-Sided Opening w Sill Flashing–WFS
AP Panel - Window or 4-Sided Opening with Sill Flashing – WFS
Notes: ·
Drill Ø1/8" holes for Blind Rivets.
· Rivets spaced at 7'-0" C.C. are temporary fasteners. · ** #12-14 X 1-1/4", Blanket Insulation <=4" thickness. · ** #12-14 X 2", Blanket Insulation >4" thickness. · LCT1 or LCT2 used with Liner/Backer. Refer to Liner or Partition Panel Dwg.
LINER COVER TRIM (LCT1)
1/8" X 3/8" BLIND RIVET, 7'-0" C.C. WITH LINER COVER TRIM (LCT)
OPENING WIDTH
**#12-14 X 1 1/4" (12" C.C.)
OPENING WIDTH
2 1/4"
JAMB
LINER COVER TRIM (LCT2)
JAMB
BL
1/8" X 3/8" BLIND RIVET (7'-0" C.C.) (TYP.)
LINER COVER TRIM (LCT2)
JAMB TRIM (JTA)
FRAMED OPENING DETAILS AT JAMB
JAMB TRIM (JTA) SHEETING SUPPORT (SSP)
BL
WALL PANEL 1/4-14 X 7/8" (12" C.C.)
HEADER TRIM WITH TROUGH (HTT) SPECIAL PLATE. REFER TO FRAMING PLANS FOR PIECE MARK (PL) LINER COVER TRIM (LCT2) 1/8" X 3/8" BLIND RIVET (7'-0" C.C.) (TYP.) GIRT #12-14 X 1" PANCAKE HEAD (36" C.C.) (TYP.)
BL
TRIM DETAILS AT JAMB
1/8" X 3/8" BLIND RIVET (3'-0" C.C.) (TYP.)
Provide air gap of 1/4" min. at bottom of panel to avoid corrosion.
BL
**#12-14 X 1 1/4" (12" C.C.) INSIDE CLOSURE WALL PANEL
ZEE GIRT
LINER COVER TRIM (LCT1)
SPECIAL PLATE. REFER TO FRAMING PLANS FOR PIECE MARK (PL)
OPENING
1
4 "
SILL TRIM FLASHING (WFS)
1
4 "
HEADER TRIM WITH TROUGH (HTT) LINER COVER TRIM (LCT2)
GIRT/SILL
OPENING HEIGHT
CEE HEADER
OPENING DETAILS AT HEADER AND SILL
TRIM DETAILS AT HEADER
4 1/4"
BL
LINER COVER TRIM (LCT1)
1/8" X 3/8" BLIND RIVET (12" C.C.)
SILL TRIM FLASHING (WFS)
OPENING HEIGHT
HEADER TRIM (HT)
NOTCH WALL PANEL FOR EXTENSION OF TRIM.
1/4-14 X 7/8" (12" C.C.)
INSIDE CLOSURE **#12-14 X 1 1/4" (12 "C.C.) WALL PANEL
JAMB TRIM (JTA)
SILL TRIM FLASHING (WFS)
4 1/4"
GIRT/SILL
TRIM DETAIL AT SILL (WFS)
TRIM DETAIL AT CORNER
AP Window or 4-Sided Opening w Trim Only
AP Panel - Window or 4-Sided Opening with Trim Only
BL
LINER COVER TRIM (LCT1)
FRAMING (NOT BY CHIEF)
**#12-14 X 1 1/4" (6" C.C.)
INSIDE CLOSURE WALL PANEL
OPENING WIDTH
HEADER TRIM WITH THROUGH (HTT)
**#12-14 X 1 1/4" (12" C.C.)
LINER COVER TRIM (LCT2)
1
4 "
BL
FRAMING (NOT BY CHIEF)
JAMB TRIM (JTA)
WALL PANEL 1/4-14 X 7/8" (12" C.C.)
LINER COVER TRIM (LCT2) LINER COVER TRIM (LCT1) Provide air gap of 1/4" min. at bottom of panel to avoid corrosion.
SHEETING SUPPORT (SSP)
OPENING HEIGHT
TRIM ONLY HEADER DETAILS
TRIM ONLY JAMB DETAILS
Notes: ·
BL
LINER COVER TRIM (LCT1)
LINER COVER TRIM (LCT2)
Drill Ø1/8" holes for Blind Rivets.
· Rivets spaced at 7'-0" C.C. are temporary fasteners. · ** #12-14 X 1-1/4", Blanket Insulation <=4" thickness. · ** #12-14 X 2", Blanket Insulation >4" thickness. · LCT1 or LCT2 used with Liner/Backer. Refer to Liner or Partition Panel Dwg.
JAMB TRIM (JT)
FRAMING (NOT BY CHIEF)
4 1/4"
INSIDE CLOSURE **#12-14 X 1 1/4" (12 "C.C.)
JAMB TRIM (JT)
WALL PANEL
HEADER TRIM WITH TROUGH (HTT)
LINER COVER TRIM (LCT1)
BL
NOTCH WALL PANEL FOR EXTENSION OF TRIM.
1/8" X 3/8" BLIND RIVET (12" C.C.)
1/4-14 X 7/8" (12" C.C.)
JAMB TRIM (JTA)
SILL TRIM FLASHING (WFS) INSIDE CLOSURE **#12-14 X 1 1/4" (12" C.C.)
FRAMING (NOT BY CHIEF)
SILL TRIM ( JT / WFS)
SILL TRIM (WFS)
WALL PANEL
4 1/4" TRIM DETAIL AT CORNER
TRIM DETAILS AT SILL
CS Panel Openings
CS Panel Openings
CS Metal Bldg Walkdoor-KD-Others
CS Panel - Metal Building Walkdoor -- Knocked-Down (by Chief) or Door Not by Chief Refer to Order Documents for Doors by Chief
Installation Steps: 1. Install Wrap Plate. 2. Liner Cover Trim(LCT), if applicable. Use with Liner/Backer. Refer to Liner or Partition Panel Drawings. 3. Door. 4. Jamb Trim (JT) with notch at header. 5. Header Trim (HTT). 6. Notch and slit wall panel. 7. Place wall panel over trims with foam inside closure. 8. Cover Trim (COT). Notes: · Drill Ø1/8" holes for Blind Rivets. · Rivets spaced at 7'-0" C.C. are temporary fasteners. · ** #12-14 X 1-1/4", Blanket Insulation <=4" thickness. · ** #12-14 X 2", Blanket Insulation >4" thickness.
Head Trim (HTT) lapped 3" min. past flat of Jamb Trim (JT). Flush with Cover Trim (COT).
2" JAMB TRIM NOTCH
2" X 1/4" PANEL NOTCH
HEADER TRIM (HTT)
Optional Urethane caulk around 1" panel slit and under COT (NOT BY CHIEF) (TYP.)
1" PANEL SLIT
INSIDE CLOSURE
JAMB TRIM (JT)
For best weathertightness performance, JT/COT and Head Trim assembly should land in flat of panel. Layout, verify, and consider field locating framed opening as necessary. If this condition cannot be achieved, special field trim modifications, omitting COT trim, and/or additional urethane caulking Not By Chief may be required.
1" SLIT
2" X 1/4" NOTCH
2" JAMB TRIM NOTCH
COVER TRIM (COT)
DOOR FRAME
FLAT OF JAMB TRIM FLAT OF HEAD TRIM
TRIM DETAIL AT CORNERS
WALL PANEL SLIT
LINER COVER TRIM (LCT1 OR LCT2) (Field modify as req'd) 1/8" X 3/8" BLIND RIVET (7'-0" C.C.) (TYP.)
WALL PANEL
#12-14 X 1" PANCAKE HEAD FASTENER (36" C.C.)
BL
OPENING WIDTH
**#12-14 X 1 1/4" (6" C.C.) INSIDE CLOSURE HEADER TRIM (HTT) 1/8" X 3/8" BLIND RIVET (7'-0" C.C.)
ZEE GIRT
JAMB
1/8" X 3/8" BLIND RIVET (3'-0" C.C.) TYP. SPECIAL PLATE. REFER TO FRAMING PLANS FOR PIECE MARK (PL)
NOMINAL DOOR OPENING
* 1 4 "
LINER COVER TRIM (LCT1 OR LCT2) (Field modify as req'd)
DOOR FRAME
BL
JAMB TRIM (JT)
1
2 " MIN.
WALL PANEL
CUT RIB AS NEEDED
***1/8"-3/4"
DOOR FRAME
OPENING HEIGHT
**#12-14 X 1 1/4" (12" C.C.) COVER TRIM (COT) 1/8" X 3/8" BLIND RIVET (18" C.C.)
NOMINAL
*** Locate JT/COT/HTT trim
DOOR OPENING
* Provide air gap of 1/4" min. at bottom of panel to avoid corrosion.
assembly to cover door frame avoiding interference with latch, door and hinges.
CEE HEADER
WALKDOOR HEADER TRIM DETAILS
WALKDOOR JAMB TRIM DETAILS
CS Metal Bldg Walkdoor-PA-SF
CS Panel- Metal Building Walkdoor - Pre-Assembled (by Chief) or Self-Framing Not by Chief Refer to Order Documents for Doors Supplied by Chief
Installation Steps: 1. Install Wrap Plate. 2. Door. 3. Jamb Trim (JT) with notch at header. 4. Header Trim (HTT). 5. Notch and slit wall panel. 6. Place wall panel over trims with foam inside closure. 7. Cover Trim (COT). 8. Liner Cover Trim(LCT), if applicable. Use with Liner/Backer. Refer to Liner or Partition Panel Drawings. Notes: · Drill Ø1/8" holes for Blind Rivets. · Rivets spaced at 7'-0" C.C. are temporary fasteners. · ** #12-14 X 1-1/4", Blanket Insulation <=4" thickness. · ** #12-14 X 2", Blanket Insulation >4" thickness.
Head Trim (HTT) lapped 3" min. past flat of Jamb Trim (JT). Flush with Cover Trim (COT).
2" JAMB TRIM NOTCH
2" X 1/4" PANEL NOTCH
HEADER TRIM (HTT)
1" PANEL SLIT
Optional Urethane caulk around 1" panel slit and under COT (NOT BY CHIEF) (TYP.)
INSIDE CLOSURE
For best weathertightness performance, JT/COT and Head Trim assembly should land in flat of panel. Layout, verify, and consider field locating framed opening as necessary. If this condition cannot be achieved, special field trim modifications, omitting COT trim, and/or additional urethane caulking Not By Chief may be required.
JAMB TRIM (JT)
1" SLIT
2" X 1/4" NOTCH
2" JAMB TRIM NOTCH
COVER TRIM (COT)
DOOR FRAME
FLAT OF JAMB TRIM FLAT OF HEAD TRIM
WALL PANEL SLIT AND NOTCH (Typical at Sill)
TRIM DETAIL AT CORNERS
LINER COVER TRIM (LCT1 OR LCT2) (Field modify as req'd) 1/8" X 3/8" BLIND RIVET (7'-0" C.C.) (TYP.)
WALL PANEL
#12-14 X 1" PANCAKE HEAD FASTENER (36" C.C.)
BL
OPENING WIDTH
**#12-14 X 1 1/4" (6" C.C.) INSIDE CLOSURE HEADER TRIM (HTT) 1/8" X 3/8" BLIND RIVET (7'-0" C.C.)
ZEE GIRT
DOOR SUBFRAME
1/8" X 3/8" BLIND RIVET (3'-0" C.C.) TYP. SPECIAL PLATE. REFER TO FRAMING PLANS FOR PIECE MARK (PL)
NOMINAL DOOR OPENING
* 1 4 "
LINER COVER TRIM (LCT1 OR LCT2) (Field modify as req'd)
DOOR FRAME
BL
JAMB TRIM (JT)
1
2 " MIN.
WALL PANEL
CUT RIB AS NEEDED
***1/8"-3/4"
DOOR FRAME
OPENING HEIGHT
**#12-14 X 1 1/4" (12" C.C.) COVER TRIM (COT) 1/8" X 3/8" BLIND RIVET (18" C.C.)
NOMINAL
*** Locate JT/COT/HTT trim
DOOR OPENING
* Provide air gap of 1/4" min. at bottom of panel to avoid corrosion.
assembly to cover door frame avoiding interference with latch, door and hinges.
CEE HEADER
WALKDOOR HEADER TRIM DETAILS
WALKDOOR JAMB TRIM DETAILS
CS OHD or 3-Sided Opening
CS Panel - OHD or 3-Sided Opening
Installation Steps: 1. Door Trim (DT), if applicable. 2. Jamb Trim (JT) with notch at header. 3. Header Trim (HTT). 4. Notch and slit wall panel. 7. Place wall panel over trims with foam inside closure. 8. Cover Trim (COT). Notes: · Drill Ø1/8" holes for Blind Rivets. · Rivets spaced at 7'-0" C.C. are temporary fasteners. · ** #12-14 X 1-1/4", Blanket Insulation <=4" thickness. · ** #12-14 X 2", Blanket Insulation >4" thickness.
Head Trim (HTT) lapped 3" min. past flat of Jamb Trim (JT). Flush with Cover Trim (COT).
2" JAMB TRIM NOTCH
2" X 1/4" PANEL NOTCH
HEADER TRIM (HTT)
1" PANEL SLIT
Optional Urethane caulk around 1" panel slit and under COT (NOT BY CHIEF) (TYP.)
INSIDE CLOSURE
For best weathertightness performance, JT/COT and Head Trim assembly should land in flat of panel. Layout, verify, and consider field locating framed opening as necessary. If this condition cannot be achieved, special field trim modifications, omitting COT trim, and/or additional urethane caulking Not By Chief may be required.
JAMB TRIM (JT)
1" SLIT
2" X 1/4" NOTCH
2" JAMB TRIM NOTCH
DOOR TRIM (DT) OPTIONAL. REFER TO PANEL DRAWINGS.
COVER TRIM (COT)
FLAT OF JAMB TRIM FLAT OF HEAD TRIM
WALL PANEL SLIT AND NOTCH (Typical at Sill)
TRIM DETAIL AT CORNERS
1/8" X 3/8" BLIND RIVET, 18" C.C. WITH DOOR TRIM (DT)
WALL PANEL
BL
OPENING WIDTH
1/8" X 3/8" BLIND RIVET (7'-0" C.C.)
**#12-14 X 1 1/4" (6" C.C.) INSIDE CLOSURE
JAMB
DOOR TRIM (DT) (OPTIONAL) REFER TO PANEL DRAWINGS
HEADER
1/8" X 3/8" BLIND RIVET (7'-0" C.C.) (TYP.)
HEADER TRIM (HTT)
* 1 4 "
BL
1/8" X 3/8" BLIND RIVET, 18" C.C. WITH DOOR TRIM (DT)
JAMB TRIM (JT)
WALL PANEL **#12-14 X 1 1/4" (12" C.C.) COVER TRIM (COT) 1/8" X 3/8" BLIND RIVET (18" C.C.)
DOOR TRIM (DT) (OPTIONAL) REFER TO PANEL DRAWINGS
CUT RIB AS NEEDED
OPENING HEIGHT
For Walkdoors to avoidinterference with latch, door, or hinges, hold JT/COT/HTT trim assembly back from jamb max 3/4", as necessary
* Provide air gap of 1/4" min. at bottom of panel to avoid corrosion.
WALKDOOR HEADER TRIM DETAILS
WALKDOOR JAMB TRIM DETAILS
CS Window by Chief
CS Panel - Window by Chief
Header Trim (HTT) and Sill Trim (JT) lapped 3" min. past flat of Jamb Trim (JT). Flush with Cover Trim (COT).
Installation Steps: 1. Install Wrap Plate, if applicable. 2. Liner Cover Trim(LCT), if applicable. Use with Liner/Backer. Refer to Liner or Partition Panel Drawings. 3. Window with Bulbtite. 4. Sill Jamb Trim (JT), slit and fold up at jamb. 5. Jamb Trim (JT) with notch at header. 6. Header Trim (HTT). 7. Notch and slit wall panel. 8. Place wall panel over trims with foam inside closures. 9. Cover Trim (COT). Notes: · Drill Ø1/8" holes for Blind Rivets. · Rivets spaced at 7'-0" C.C. are temporary fasteners. · ** #12-14 X 1-1/4", Blanket Insulation <=4" thickness. · ** #12-14 X 2", Blanket Insulation >4" thickness.
2" JAMB TRIM NOTCH
2" X 1/4" PANEL NOTCH
1" PANEL SLIT
JAMB TRIM (JT) INSIDE CLOSURE HEADER TRIM (HTT)
LINER COVER TRIMS
For best weathertightness performance, JT/COT and Head/Sill Trim assembly should land in flat of panel. Layout, verify, and consider field locating framed opening as necessary. If this condition cannot be achieved, special field trim modifications, omitting COT trim, and/or additional urethane caulking Not By Chief may be required.
1" SLIT
2" X 1/4" NOTCH
3" TO FLAT OF JAMB TRIM
2" JAMB TRIM NOTCH
COVER TRIM (COT)
SILL JAMB TRIM (JT)
Optional Urethane caulk around 1" panel slit and under COT (NOT BY CHIEF) (TYP.)
NOTCH AND SLIT WALL PANEL FOR EXTENSION OF TRIM. (TYP.) **#12-14 X 1 1/4" (6" C.C.) (TYP.) WALL PANEL
FLAT OF JAMB TRIM FLAT OF HEAD TRIM
WALL PANEL SLIT (Typical at Sill)
TRIM DETAIL AT CORNERS
(Window not Shown)
ZEE GIRT #12-14 X 1" PANCAKE HEAD (36" C.C.) (TYP.)
BL
1/8" X 3/8" BLIND RIVET, (18" C.C.) WITH LINER COVER TRIM (LCT) 3/16" BULBTITE RIVET (12" C.C.) (SIDE ONLY) JAMB 1/8" X 3/8" BLIND RIVET (7'-0" C.C.) (TYP.)
1/8" X 3/8" BLIND RIVET (7'-0" C.C.)
**#12-14 X 1 1/4" (6" C.C.)
LINER COVER TRIM (LCT1)
CEE HEADER
INSIDE CLOSURE
OPENING WIDTH
* 1 4 "
1/8" X 3/8" BLIND RIVET, 18" C.C. WITH COVER TRIM (LCT)
HEADER TRIM (HTT) WINDOW BY CHIEF URETHANE CAULK (NOT BY CHIEF)
LINER COVER TRIM (LCT2)
LINER COVER TRIM (LCT1)
SPECIAL PLATE. REFER TO FRAMING PLANS FOR PIECE MARK (PL) LINER COVER TRIM (LCT2)
BL
1/8" X 3/8" BLIND RIVET, 18" C.C. WITH COVER TRIM (LCT) * Provide air gap of 1/4" min. at bottom of panel to avoid corrosion.
**#12-14 X 1 1/4" (12" C.C.) WALL PANEL
OPENING
JAMB TRIM (JT)
CUT RIB AS NEEDED
URETHANE CAULK (NOT BY CHIEF)
1/8" X 3/8" BLIND RIVET (18" C.C.) (TYP.) COVER TRIM (COT)
URETHANE CAULK (NOT BY CHIEF)
SILL JAMB TRIM (JT) INSIDE CLOSURE **#12-14 X 1 1/4" (6" C.C.)
GIRT/SILL
1/8" x 3/8" BLIND RIVET (7'-0" C.C.)
WALL PANEL (TYP.)
CHIEF WINDOW HEADER AND SILL
FRAMED OPENING DETAILS AT JAMB
CS Window or 4-Sided Opening w Jamb Trim-JT
CS Panel - Window Not by Chief or 4-Sided Opening with Sill Jamb Trim – JT
Header Trim (HTT) and Sill Trim (JT) lapped 3" min. past flat of Jamb Trim (JT). Flush with Cover Trim (COT).
Installation Steps: 1. Install Wrap Plate, if applicable. 2. Liner Cover Trim(LCT), if applicable. Use with Liner/Backer. Refer to Liner or Partition Panel Drawings. 3. Sill Jamb Trim (JT), slit and fold up at jamb. 4. Jamb Trim (JT) with notch at header. 5. Header Trim (HTT). 6. Notch and slit wall panel. 7. Place wall panel over trims with foam inside closures. 8. Cover Trim (COT). Notes: · Drill Ø1/8" holes for Blind Rivets. · Rivets spaced at 7'-0" C.C. are temporary fasteners. · ** #12-14 X 1-1/4", Blanket Insulation <=4" thickness. · ** #12-14 X 2", Blanket Insulation >4" thickness.
2" JAMB TRIM NOTCH
2" X 1/4" PANEL NOTCH
1" PANEL SLIT
JAMB TRIM (JT) INSIDE CLOSURE HEADER TRIM (HTT)
LINER COVER TRIMS
For best weathertightness performance, JT/COT and Head/Sill Trim assembly should land in flat of panel. Layout, verify, and consider field locating framed opening as necessary. If this condition cannot be achieved, special field trim modifications, omitting COT trim, and/or additional urethane caulking Not By Chief may be required.
1" SLIT
2" X 1/4" NOTCH
3" TO FLAT OF JAMB TRIM
2" JAMB TRIM NOTCH
COVER TRIM (COT)
SILL JAMB TRIM (JT) NOTCH AND SLIT WALL PANEL FOR EXTENSION OF TRIM. (TYP.) **#12-14 X 1 1/4" (6" C.C.) (TYP.) WALL PANEL
Optional Urethane caulk around 1" panel slit and under COT (NOT BY CHIEF) (TYP.)
FLAT OF JAMB TRIM FLAT OF HEAD TRIM
WALL PANEL SLIT AND NOTCH (Typical at Sill)
TRIM DETAIL AT CORNERS
(Window not Shown)
ZEE GIRT #12-14 X 1" PANCAKE HEAD (36" C.C.) (TYP.) **#12-14 X 1 1/4" (6" C.C.)
BL
1/8" X 3/8" BLIND RIVET, (18" C.C.) WITH LINER COVER TRIM (LCT)
1/8" X 3/8" BLIND RIVET (7'-0" C.C.)
LINER COVER TRIM (LCT1)
INSIDE CLOSURE
CEE HEADER
* 1 4 " * Provide air gap of 1/4" min. at bottom of panel to avoid corrosion.
1/8" X 3/8" BLIND RIVET, 18" C.C. WITH COVER TRIM (LCT)
OPENING WIDTH
JAMB 1/8" X 3/8" BLIND RIVET (7'-0" C.C.) (TYP.)
HEADER TRIM (HTT)
LINER COVER TRIM (LCT2)
LINER COVER TRIM (LCT1)
SPECIAL PLATE. REFER TO FRAMING PLANS FOR PIECE MARK (PL) LINER COVER TRIM (LCT2)
BL
**#12-14 X 1 1/4" (12" C.C.) WALL PANEL
JAMB TRIM (JT)
OPENING
CUT RIB AS NEEDED
1/8" X 3/8" BLIND RIVET, 18" C.C. WITH COVER TRIM (LCT)
1/8" X 3/8" BLIND RIVET (18" C.C.) (TYP.) COVER TRIM (COT)
SILL JAMB TRIM (JT)
INSIDE CLOSURE **#12-14 X 1 1/4" (6" C.C.)
GIRT/SILL
1/8" x 3/8" BLIND RIVET (7'-0" C.C.)
WALL PANEL (TYP.)
OPENING DETAILS AT HEADER AND SILL
FRAMED OPENING DETAILS AT JAMB
CS Window or 4-Sided Opening w Sill Flashing-WFS
CS Panel - Window Not by Chief or 4-Sided Opening with Sill Flashing – WFS
Header Trim (HTT) and Sill Trim (JT) lapped 3" min. past flat of Jamb Trim (JT). Flush with Cover Trim (COT).
Installation Steps: 1. Install Wrap Plate, if applicable. 2. Liner Cover Trim(LCT), if applicable. Use with Liner/Backer. Refer to Liner or Partition Panel Drawings. 3. Sill Trim Flashing (WFS), slit and fold up at jamb. 4. Jamb Trim (JT) with notch at header. 5. Header Trim (HTT). 6. Notch and slit wall panel. 7. Place wall panel over trims with foam inside closures. 8. Cover Trim (COT). Notes: · Drill Ø1/8" holes for Blind Rivets. · Rivets spaced at 7'-0" C.C. are temporary fasteners. · ** #12-14 X 1-1/4", Blanket Insulation <=4" thickness. · ** #12-14 X 2", Blanket Insulation >4" thickness.
2" JAMB TRIM NOTCH
2" X 1/4" PANEL NOTCH
1" PANEL SLIT
JAMB TRIM (JT) INSIDE CLOSURE HEADER TRIM (HTT)
LINER COVER TRIMS
FIELD VERIFY WFS OFFSET
For best weathertightness performance, JT/COT and Head/Sill Trim assembly should land in flat of panel. Layout, verify, and consider field locating framed opening as necessary. If this condition cannot be achieved, special field trim modifications, omitting COT trim, and/or additional urethane caulking Not By Chief may be required.
2" X 1/4" NOTCH
1" SLIT
3" TO FLAT OF JAMB TRIM
2" JAMB TRIM NOTCH
COVER TRIM (COT)
NOTCH AND SLIT WALL PANEL FOR EXTENSION OF TRIM. (TYP.) **#12-14 X 1 1/4" (6" C.C.) (TYP.) WALL PANEL SILL TRIM FLASHING (WFS) 1/8" X 3/8" BLIND RIVET (12" C.C.)
Optional Urethane caulk around 1" panel slit and under COT (NOT BY CHIEF) (TYP.)
FLAT OF JAMB TRIM FLAT OF HEAD TRIM
WALL PANEL SLIT AND NOTCH (Typical at Sill)
TRIM DETAIL AT CORNERS
(Window not Shown)
ZEE GIRT #12-14 X 1" PANCAKE HEAD (36" C.C.) (TYP.)
BL
1/8" X 3/8" BLIND RIVET, (18" C.C.) WITH LINER COVER TRIM (LCT)
1/8" X 3/8" BLIND RIVET (7'-0" C.C.)
**#12-14 X 1 1/4" (6" C.C.)
LINER COVER TRIM (LCT1)
INSIDE CLOSURE
CEE HEADER
* 1 4 "
* Provide air gap of 1/4" min. at bottom of panel to avoid corrosion.
1/8" X 3/8" BLIND RIVET (3'-0" C.C.)
OPENING WIDTH
JAMB 1/8" X 3/8" BLIND RIVET (7'-0" C.C.) (TYP.)
LINER COVER TRIM (LCT2)
HEADER TRIM (HTT)
LINER COVER TRIM (LCT1)
GIRT/SILL INSIDE CLOSURE **#12-14 X 1 1/4" (6" C.C.) WALL PANEL (TYP.) SILL TRIM FLASHING (WFS) SPECIAL PLATE. REFER TO FRAMING PLANS FOR PIECE MARK (PL) LINER COVER TRIM (LCT2)
BL
**#12-14 X 1 1/4" (12" C.C.) WALL PANEL
JAMB TRIM (JT)
OPENING
1/8" X 3/8" BLIND RIVET (3'-0" C.C.) 1/8" X 3/8" BLIND RIVET (12" C.C.)
CUT RIB AS NEEDED
1/8" X 3/8" BLIND RIVET (18" C.C.) (TYP.) COVER TRIM (COT)
OPENING DETAILS AT HEADER AND SILL
FRAMED OPENING DETAILS AT JAMB
CS Trim Only 4-Sided Opening w Jamb Trim-JT
CS Panel - Trim Only 4-Sided Opening with Sill Jamb Trim – JT
Header Trim (HTT) and Sill Trim (JT) lapped 3" min. past flat of Jamb Trim (JT). Flush with Cover Trim (COT).
Installation Steps: 1. Install Wrap Plate, if applicable. 2. Liner Cover Trim(LCT), if applicable. Use with Liner/Backer. Refer to Liner or Partition Panel Drawings. 3. Sill Jamb Trim (JT), slit and fold up at jamb. 4. Jamb Trim (JT) with notch at header. 5. Header Trim (HTT). 6. Notch and slit wall panel. 7. Place wall panel over trims with foam inside closures. 8. Cover Trim (COT). Notes: · Drill Ø1/8" holes for Blind Rivets. · Rivets spaced at 7'-0" C.C. are temporary fasteners. · ** #12-14 X 1-1/4", Blanket Insulation <=4" thickness. · ** #12-14 X 2", Blanket Insulation >4" thickness.
2" JAMB TRIM NOTCH
2" X 1/4" PANEL NOTCH
1" PANEL SLIT
JAMB TRIM (JT) INSIDE CLOSURE HEADER TRIM (HTT)
LINER COVER TRIMS
For best weathertightness performance, JT/COT and Head/Sill Trim assembly should land in flat of panel. Layout, verify, and consider field locating framed opening as necessary. If this condition cannot be achieved, special field trim modifications, omitting COT trim, and/or additional urethane caulking Not By Chief may be required.
1" SLIT
2" X 1/4" NOTCH
3" TO FLAT OF JAMB TRIM
2" JAMB TRIM NOTCH
COVER TRIM (COT)
SILL JAMB TRIM (JT) NOTCH AND SLIT WALL PANEL FOR EXTENSION OF TRIM. (TYP.) **#12-14 X 1 1/4" (6" C.C.) (TYP.) WALL PANEL
Optional Urethane caulk around 1" panel slit and under COT (NOT BY CHIEF) (TYP.)
FLAT OF JAMB TRIM FLAT OF HEAD TRIM
WALL PANEL SLIT AND NOTCH (Typical at Sill)
TRIM DETAIL AT CORNERS
* Provide air gap of 1/4" min. at bottom of panel to avoid corrosion.
BL
FRAMING (NOT BY CHIEF)
1/8" X 3/8" BLIND RIVET, (18" C.C.) WITH LINER COVER TRIM (LCT) FRAMING (NOT BY CHIEF) 1/8" X 3/8" BLIND RIVET (7'-0" C.C.) (TYP.)
**#12-14 X 1 1/4" (6" C.C.)
1/8" X 3/8" BLIND RIVET (7'-0" C.C.)
LINER COVER TRIM (LCT1)
INSIDE CLOSURE
* 1 4 "
1/8" X 3/8" BLIND RIVET, 18" C.C. WITH COVER TRIM (LCT)
OPENING WIDTH
HEADER TRIM (HTT)
LINER COVER TRIM (LCT2)
LINER COVER TRIM (LCT1)
BL
**#12-14 X 1 1/4" (12" C.C.) WALL PANEL
JAMB TRIM (JT)
OPENING
CUT RIB AS NEEDED
LINER COVER TRIM (LCT2)
1/8" X 3/8" BLIND RIVET, 18" C.C. WITH COVER TRIM (LCT)
1/8" X 3/8" BLIND RIVET (18" C.C.) (TYP.) COVER TRIM (COT)
SILL JAMB TRIM (JT) INSIDE CLOSURE **#12-14 X 1 1/4" (6" C.C.) WALL PANEL (TYP.)
FRAMING (NOT BY CHIEF)
1/8" x 3/8" BLIND RIVET (7'-0" C.C.)
OPENING DETAILS AT HEADER AND SILL
FRAMED OPENING DETAILS AT JAMB
CS Trim Only 4-Sided Opening w Sill Flashing-WFS
CS Panel - Trim Only 4-Sided Opening with Sill Flashing – WFS
Header Trim (HTT) and Sill Trim (JT) lapped 3" min. past flat of Jamb Trim (JT). Flush with Cover Trim (COT).
Installation Steps: 1. Install Wrap Plate, if applicable. 2. Liner Cover Trim(LCT), if applicable. Use with Liner/Backer. Refer to Liner or Partition Panel Drawings. 3. Sill Trim Flashing (WFS), slit and fold up at jamb. 4. Jamb Trim (JT) with notch at header. 5. Header Trim (HTT). 6. Notch and slit wall panel. 7. Place wall panel over trims with foam inside closures. 8. Cover Trim (COT). Notes: · Drill Ø1/8" holes for Blind Rivets. · Rivets spaced at 7'-0" C.C. are temporary fasteners. · ** #12-14 X 1-1/4", Blanket Insulation <=4" thickness. · ** #12-14 X 2", Blanket Insulation >4" thickness.
2" JAMB TRIM NOTCH
2" X 1/4" PANEL NOTCH
1" PANEL SLIT
JAMB TRIM (JT) INSIDE CLOSURE HEADER TRIM (HTT)
LINER COVER TRIMS
FIELD VERIFY WFS OFFSET
For best weathertightness performance, JT/COT and Head/Sill Trim assembly should land in flat of panel. Layout, verify, and consider field locating framed opening as necessary. If this condition cannot be achieved, special field trim modifications, omitting COT trim, and/or additional urethane caulking Not By Chief may be required.
1" SLIT
2" X 1/4" NOTCH
3" TO FLAT OF JAMB TRIM
2" JAMB TRIM NOTCH
COVER TRIM (COT)
NOTCH AND SLIT WALL PANEL FOR EXTENSION OF TRIM. (TYP.) **#12-14 X 1 1/4" (6" C.C.) (TYP.) WALL PANEL SILL TRIM FLASHING (WFS) 1/8" X 3/8" BLIND RIVET (12" C.C.)
Optional Urethane caulk around 1" panel slit and under COT (NOT BY CHIEF) (TYP.)
FLAT OF JAMB TRIM FLAT OF HEAD TRIM
WALL PANEL SLIT AND NOTCH (Typical at Sill)
TRIM DETAIL AT CORNERS
BL
1/8" X 3/8" BLIND RIVET, (18" C.C.) WITH LINER COVER TRIM (LCT) FRAMING (NOT BY CHIEF) 1/8" X 3/8" BLIND RIVET (7'-0" C.C.) (TYP.)
1/8" X 3/8" BLIND RIVET (7'-0" C.C.)
FRAMING (NOT BY CHIEF)
**#12-14 X 1 1/4" (6" C.C.)
LINER COVER TRIM (LCT1)
INSIDE CLOSURE
* 1 4 " * Provide air gap of 1/4" min. at bottom of panel to avoid corrosion.
1/8" X 3/8" BLIND RIVET, 18" C.C. WITH COVER TRIM (LCT)
OPENING WIDTH
HEADER TRIM WITH TROUGH (HTT)
LINER COVER TRIM (LCT2)
LINER COVER TRIM (LCT1)
BL
**#12-14 X 1 1/4" (12" C.C.) WALL PANEL
JAMB TRIM (JT)
OPENING
LINER COVER TRIM (LCT2)
CUT RIB AS NEEDED
FRAMING (NOT BY CHIEF) 1/8" X 3/8" BLIND RIVET, 18" C.C. WITH COVER TRIM (LCT) 1/8" x 3/8" BLIND RIVET (12" C.C.)
1/8" X 3/8" BLIND RIVET (18" C.C.) (TYP.) COVER TRIM (COT)
SILL TRIM FLASHING (WFS) INSIDE CLOSURE ** #12-14 X 1 1/4" (6" C.C.) WALL PANEL (TYP.)
OPENING DETAILS AT HEADER AND SILL
FRAMED OPENING DETAILS AT JAMB
Wainscot - Lapped
Wainscot Lapped
T19.Wainscot Lapped at Zee w A-20
BL
UPPER WALL PANEL
RAKE ANGLE (A-20)
#12-14 X 1 1/4" (6" C.C. AT CS PANEL) (12" C.C. AT AP PANEL)
(2) #12-14 X 1 1/4" (36" C.C.) (UPPER WALL PANEL COLOR)
XXX'-X"
3" 3"
WAINSCOT GIRT(WINDOW SILL HEIGHT) WAINSCOT PANEL
T19
TRANSITION FROM WALL PANEL TO WAINSCOT WITH PANELS LAPPED
T21.Wainscot Lapped HRC
BL
UPPER WALL PANEL
RAKE ANGLE (A-20) #12-14 X 1 1/4"
(6" C.C. AT CS PANEL) (12" C.C. AT AP PANEL) (2) #12-24 X 1 1/2" (36" C.C.) (UPPER WALL PANEL COLOR)
XXX'-X"
3" 3"
WAINSCOT GIRT (WINDOW SILL HEIGHT) WAINSCOT PANEL
T21
TRANSITION FROM WALL PANEL TO WAINSCOT WITH PANELS LAPPED
T22.Wainscot Lapped Zee
BL
UPPER WALL PANEL
WAINSCOT GIRT OR SILL XXX'-X"
3" 3"
#12-14 X 1 1/4" (6" C.C. AT CS PANEL) (12" C.C. AT AP PANEL)
WAINSCOT PANEL
T22
TRANSITION FROM WALL PANEL TO WAINSCOT WITH PANELS LAPPED
Wainscot Lapped at Sill
BL
#12-14 X 1 1/4" (6" C.C. for CS PANEL) (12" C.C. for AP PANEL) UPPER WALL PANEL
WAINSCOT GIRT (WINDOW SILL HEIGHT) (2) #12-14 X 1 1/4" (36 "C.C.) (UPPER WALL PANEL COLOR) RAKE ANGLE (A-20)
6" PANEL LAP
XXX'-X"
WAINSCOT PANEL
Wainscot Lapped Mid-wall at Cee
#12-14 X 1 1/4" (TYP) (6" C.C. for CS PANEL) (12" C.C. for AP PANEL) UPPER WALL PANEL
BL
WAINSCOT GIRT (TYP)
3" 3"
XXX'-X"
WAINSCOT PANEL
3" 3"
XXX'-X"
FULL WAINSCOT COLOR
LOWER WALL PANEL
Wainscot Lapped Mid-wall at Zee
#12-14 X 1 1/4" (TYP) (6" C.C. for CS PANEL) (12" C.C. for AP PANEL) UPPER WALL PANEL
BL
WAINSCOT GIRT (TYP)
3" 3"
XXX'-X"
WAINSCOT PANEL
3" 3"
XXX'-X"
FULL WAINSCOT COLOR
LOWER WALL PANEL
Wainscot - No Lap (w WTT Trim)
Wainscot No Lap (w WTT Trim)
T15.Wainscot No Lap WTT at Cee
UPPER WALL PANEL RAKE ANGLE (A-20) WAINSCOT TRANSITION TRIM (WTT) (WAINSCOT COLOR) INSIDE CLOSURE
BL
#12-14 X 1 1/4" (TYP.) (6" C.C. AT CS PANEL) (12" C.C. AT AP PANEL) (2) #12-14 X 1 1/4" (36" C.C.) (UPPER WALL PANEL COLOR)
Provide air gap of 1/4" min. at bottom of panel to avoid corrosion.
1
4 "
XXX'-X"
WAINSCOT GIRT OR SILL INSIDE CLOSURE WAINSCOT PANEL
T15
TRANSITION FROM WALL PANEL TO WAINSCOT WITH PANELS NOT LAPPED
T17.Wainscot No Lap WTT at HRC
UPPER WALL PANEL RAKE ANGLE (A-20) WAINSCOT TRANSITION TRIM (WTT) (WAINSCOT COLOR) INSIDE CLOSURE
BL
#12-14 X 1 1/4" (TYP.) (6" C.C. AT CS PANEL) (12" C.C. AT AP PANEL) (2) #12-24 X 1 1/2" (36" C.C.) (UPPER WALL PANEL COLOR)
Provide air gap of 1/4" min. at bottom of panel to avoid corrosion.
1
4 "
XXX'-X"
WAINSCOT GIRT OR SILL (HRC)
#12-24 X 1 1/2" (6" C.C. AT CS PANEL) (12" C.C. AT AP PANEL)
INSIDE CLOSURE WAINSCOT PANEL
T17
TRANSITION FROM WALL PANEL TO WAINSCOT WITH PANELS NOT LAPPED
T18.Wainscot No Lap WTT at Zee
BL
UPPER WALL PANEL RAKE ANGLE (A-20) WAINSCOT TRANSITION TRIM (WTT) (WAINSCOT COLOR) INSIDE CLOSURE
#12-14 X 1 1/4" (TYP.) (6" C.C. AT CS PANEL) (12" C.C. AT AP PANEL) (2) #12-14 X 1 1/4" (36" C.C.) (UPPER WALL PANEL COLOR)
Provide air gap of 1/4" min. at bottom of panel to avoid corrosion.
1
4 "
XXX'-X"
WAINSCOT GIRT OR SILL INSIDE CLOSURE WAINSCOT PANEL
T18
TRANSITION FROM WALL PANEL TO WAINSCOT WITH PANELS NOT LAPPED
Wainscot No Lap WTT at Sill w Window by Chief
UPPER WALL PANEL (BEYOND) WAINSCOT TRANSITION TRIM (WTT) (WAINSCOT COLOR) (BEYOND)
BL
JAMB TRIM (JT) CHIEF WINDOW
WAINSCOT GIRT or SILL
XXX'-X"
#12-14 X 1 1/4" (6" C.C. for CS PANEL) (12" C.C. for AP PANEL) CAULK (NOT BY CHIEF)
WAINSCOT PANEL INSIDE CLOSURE
SECTION CUT THROUGH SILL OF CHIEF WINDOW AT WAINSCOT
Wainscot No Lap WTT Mid-Wall at Cee
UPPER WALL PANEL
WAINSCOT TRANSITION TRIM (WTT) (WAINSCOT COLOR)
INSIDE CLOSURE
#12-14 X 1 1/4" (TYP) (6" C.C. for CS PANEL) (12" C.C. for AP PANEL)
BL
Provide air gap of 1/4" min. at bottom of panel to avoid corrosion.
(2) #12-14 X 1 1/4" (36" C.C.) (UPPER WALL PANEL COLOR)
WAINSCOT GIRT (TYP)
1
4 "
XXX'-X"
#12-14 X 1 1/4" (TYP) (6" C.C. for CS PANEL) (12" C.C. for AP PANEL)
WAINSCOT PANEL INSIDE CLOSURE INSIDE CLOSURE
RAKE ANGLE (A-20) (TYP) (2) #12-14 X 1 1/4" (36" C.C.) (LOWER WALL PANEL COLOR)
1
4 "
FULL WAINSCOT COLOR
XXX'-X"
WAINSCOT TRANSITION TRIM (WTT) (WALL COLOR)
INSIDE CLOSURE
LOWER WALL PANEL
Made with FlippingBook - professional solution for displaying marketing and sales documents online