Wall Panel and Trim
CS Metal Bldg Walkdoor-PA-SF
CS Panel- Metal Building Walkdoor - Pre-Assembled (by Chief) or Self-Framing Not by Chief Refer to Order Documents for Doors Supplied by Chief
Installation Steps: 1. Install Wrap Plate. 2. Door. 3. Jamb Trim (JT) with notch at header. 4. Header Trim (HTT). 5. Notch and slit wall panel. 6. Place wall panel over trims with foam inside closure. 7. Cover Trim (COT). 8. Liner Cover Trim(LCT), if applicable. Use with Liner/Backer. Refer to Liner or Partition Panel Drawings. Notes: · Drill Ø1/8" holes for Blind Rivets. · Rivets spaced at 7'-0" C.C. are temporary fasteners. · ** #12-14 X 1-1/4", Blanket Insulation <=4" thickness. · ** #12-14 X 2", Blanket Insulation >4" thickness.
Head Trim (HTT) lapped 3" min. past flat of Jamb Trim (JT). Flush with Cover Trim (COT).
2" JAMB TRIM NOTCH
2" X 1/4" PANEL NOTCH
HEADER TRIM (HTT)
1" PANEL SLIT
Optional Urethane caulk around 1" panel slit and under COT (NOT BY CHIEF) (TYP.)
INSIDE CLOSURE
For best weathertightness performance, JT/COT and Head Trim assembly should land in flat of panel. Layout, verify, and consider field locating framed opening as necessary. If this condition cannot be achieved, special field trim modifications, omitting COT trim, and/or additional urethane caulking Not By Chief may be required.
JAMB TRIM (JT)
1" SLIT
2" X 1/4" NOTCH
2" JAMB TRIM NOTCH
COVER TRIM (COT)
DOOR FRAME
FLAT OF JAMB TRIM FLAT OF HEAD TRIM
WALL PANEL SLIT AND NOTCH (Typical at Sill)
TRIM DETAIL AT CORNERS
LINER COVER TRIM (LCT1 OR LCT2) (Field modify as req'd) 1/8" X 3/8" BLIND RIVET (7'-0" C.C.) (TYP.)
WALL PANEL
#12-14 X 1" PANCAKE HEAD FASTENER (36" C.C.)
BL
OPENING WIDTH
**#12-14 X 1 1/4" (6" C.C.) INSIDE CLOSURE HEADER TRIM (HTT) 1/8" X 3/8" BLIND RIVET (7'-0" C.C.)
ZEE GIRT
DOOR SUBFRAME
1/8" X 3/8" BLIND RIVET (3'-0" C.C.) TYP. SPECIAL PLATE. REFER TO FRAMING PLANS FOR PIECE MARK (PL)
NOMINAL DOOR OPENING
* 1 4 "
LINER COVER TRIM (LCT1 OR LCT2) (Field modify as req'd)
DOOR FRAME
BL
JAMB TRIM (JT)
1
2 " MIN.
WALL PANEL
CUT RIB AS NEEDED
***1/8"-3/4"
DOOR FRAME
OPENING HEIGHT
**#12-14 X 1 1/4" (12" C.C.) COVER TRIM (COT) 1/8" X 3/8" BLIND RIVET (18" C.C.)
NOMINAL
*** Locate JT/COT/HTT trim
DOOR OPENING
* Provide air gap of 1/4" min. at bottom of panel to avoid corrosion.
assembly to cover door frame avoiding interference with latch, door and hinges.
CEE HEADER
WALKDOOR HEADER TRIM DETAILS
WALKDOOR JAMB TRIM DETAILS
Made with FlippingBook - professional solution for displaying marketing and sales documents online