STC MSC Roof Panel

STC-MSC Inset Gable Lead Height Change w Panel Below

* FIELD CUT BOTTOM OF WALL PANELS TO MATCH ROOF SLOPE. PROVIDE AIR GAP OF 1/4" MIN. AT BOTTOM OF PANEL TO AVOID CORROSION.

* WALL PANEL (TYP.) #12-14 X 1 1/4" (TYP) (6" C.C. for CS PANEL) (12" C.C. for AP PANEL)

PURLIN

PURLIN CLOSURE AT RIDGE IS TO BE FIELD CUT AND FASTENED TOGETHER WITH (2) 1/8" X 3/8" BLIND RIVETS.

PURLIN CLOSURE (GPC2 OR GPC3) (TYP) (2) PURLIN CLOSURE CLIPS (GCC1) AT EACH PURLIN CLOSURE (2) #12-14 X 1 1/4" EACH CLIP (2) 1/8" X 3/8" BLIND RIVETS (EACH CLIP)

CLOSURE CLIPS (GCC-1) (TYP.)

BL

PURLIN CLOSURE (TYP.)

TRI-BEAD TAPE SEALER HEIGHT CHANGE TRIM TOP (GHMTF) INSIDE CLOSURE

SIKA 511 CAULK IN LOCKFORM OF HEIGHT CHANGE TRIM TOP (BEFORE ASSEMBLING) (SEE INSET DETAIL) PRE-GLUED THERMAL SPACER (NOT BY CHIEF) ***

PURLIN

1

4 "

(2) 1/8" X 3/8" BLIND RIVETS (TYP.)

STC/MSC ROOF PANEL

HEIGHT CHANGE ANGLE (A-20-H)

*** DRAFTING NOTE: THERMAL SPACER TO BE USED WITH NO INSULATION.

(2) #12-14 X 1 1/4"' PER CLOSURE

RAKE SUPPORT (A-20-S)

1/4-14 X 1 1/4" WT (12" C.C.)

2"

TOP VIEW

PURLIN

HEIGHT CHANGE TRIM BOTTOM (GHMBF)

HEIGHT CHANGE RAFTER

1/4-14 X 1 1/4" SHOULDER (24" C.C.)** #12-14 X 1" PANCAKE HEAD (2 EACH PURLIN)

NOTE: · Purlin closure is to be field cut between eave struts and purlins. · Closure clips may need to be field cut to fit in purlin and staggered so #12-14 X 1 1/4" fasteners don't interfere.

RAKE ANGLE (A-20)

PURLIN CLOSURE (GPC__) (PURLIN CLOSURE CLIPS NOT SHOWN)

EAVE STRUT

(2) #12-24 X 1 1/2" AT 36" C.C.

1/4-14 X 7/8" (12" C.C.)

(2) #12-14 X 1 1/4" (2) 1/8" X 3/8" BLIND RIVETS PURLIN CLOSURE CLIPS (GCC1)

** IT IS IMPORTANT THAT FASTENERS ARE INSTALLED THROUGH THE CENTER OF THE SLOTTED HOLES OF THE RAKE SUPPORT.

PANELING CAP TRIM (SCT)

SIKA 511 CAULK IN LOCKFORM OF HEIGHT CHANGE TRIM TOP (BEFORE ASSEMBLING)

PURLIN CLOSURE INSTALLATION