STC MSC Roof Panel

STC-MSC Gable End w Field Bend Vertical Leg and Termination Trim and Nichiha Panel NBC

***DRAFTING NOTE: THERMAL SPACER TO BE USED WITH NO INSULATION

TERMINATION TRIM (GTTM) 1/4-14 X 1 1/4" WT (24" C.C.) 1/4-14 X 7/8" WT (6" C.C.) TRI-BEAD TAPE SEALER #12-14 X 1 1/4" (6" C.C. for CS PANEL) (12" C.C. for AP PANEL) RAKE ANGLE (A-20-B) RAKE SUPPORT (A-20-S) SPECIAL GABLE TRIM (SPT-X) GABLE TRIM SUPPORT (GTS) (10'-0" C.C.) GABLE EXPANSION TRIM (GET) FASTENERS (NOT BY CHIEF)(12" C.C.) (2) FASTENERS (NOT BY CHIEF)

* 1/4-14 X 1 1/4" SHOULDER (24" C.C.)

1

* 1/4-14 X 1 1/4" SHOULDER (24" C.C.) 1/4-14 X 1 1/4" WT (12" C.C.) RAKE SUPPORT (A-20-S) TRI-BEAD TAPE SEALER STC/MSC ROOF PANEL (FIELD FORM 3" VERTICAL LEG TO FIT FINAL DIMENSION)

BL

SPECIAL PURCHASED (IF BY CHIEF)

***

PRE-GLUED THERMAL SPACER (NOT BY CHIEF)

RAKE ANGLE (A-20-B)

#12-14 X 1" PANCAKE HEAD (2 EACH PURLIN) (TYP) PURLIN

SPECIAL PURCHASED (IF BY CHIEF)

* IT IS IMPORTANT THAT 1/4-14 X 1 1/4" SHOULDERS ARE INSTALLED THROUGH THE CENTER OF THE SLOTTED HOLES OF THE RAKE SUPPORT.

WALL PANEL

** _" NICHIHA PANEL (NOT BY CHIEF)

** NOTE: CONNECTION OF NICHIHA PANELS (NOT BY CHIEF), TO WALL PANEL IS NOT BY CHIEF.