Special Features

Details for special conditions and other uncommon conditions; includes height changes, expansion joints, parapets, bifold doors and so much more.

Special Features Sections & Details

All details downloadable in .dwg and .pdf

Table of Contents

Height Change - Steel Uphill Cut on Back-to-Back Cee Post to Top of Height Change Rafter-Left Uphill Cut on Cee Corner Post to Top of Height Change Frame Column-Left Uphill Cut on Endwall Post to Top of Height Rafter-Left Uphill Cut on Outset Corner Post to Top of Height Change Frame Column-Left Uphill Cut on Rotated Corner Post to Top of Height Change Frame Column-Left Uphill Height Change Endwall Rafter Bracketed to Taller Endwall Post-Left Uphill Height Change Endwall Rafter Bracketed to Taller Inset Sidewall Corner Post-Left Uphill Height Change Endwall Rafter Bracketed to Taller Outset Sidewall Corner Post-Left Uphill Height Change Endwall Rafter Bracketed to Taller Rotated Corner Post-Left Height Change - Purlins CS Height Change at High Side w Eave Strut and Taller Backup Panel CS Height Change at High Side w Out Eave Strut and Taller Backup Panel Back Up Panel at Height Change - STC-MSC Roof STC-MSC Gable Field Bend Vertical Leg - Taller Backup Panel and Thermal Spacer STC-MSC Gable Lead - Taller Backup Panel and Thermal Spacer STC-MSC Gable Tail - Taller Backup Panel and Thermal Spacer STC-MSC Gable Tail Special Term Trim - Taller Backup Panel and Thermal Spacer STC-MSC High Side - Taller Backup Panel and Thermal Spacer Back Up Panel at Height Change - MVF-MVP Roof MVF-MVP Height Change at Gable Lead End w Taller Backup Panel and Thermal Spacer MVF-MVP Height Change at Gable Tail End w Taller Backup Panel and Thermal Spacer MVF-MVP Height Change at High Side w Taller Backup Panel and Thermal Spacer MVF-MVP Height Change w Cut Roof Panel at Gable Lead End - Taller Backup Panel and Thermal Spacer Multi-Gutter Multi-Gutter CS Same Height Existing Building Multi-Gutter CS Sidewall between Same Height Buildings Multi-Gutter CS Taller Building Multi-Gutter CS Taller Existing Building Multi-Gutter MVF-MVP Same Height Existing Building Multi-Gutter MVF-MVP Same Height Buildings Multi-Gutter MVF-MVP Taller Building Inset Gable Height Change w Zee Purlin-Building on Left Outset Gable Height Change w Zee Purlin-Building on Left Back Up Panel at Height Change - CS Roof CS Height Change at Gable w Taller Backup Panel

Multi-Gutter MVF-MVP Taller Existing Building Multi-Gutter STC-MSC Same Height Buildings Multi-Gutter STC-MSC Same Height Existing Building Multi-Gutter STC-MSC Taller Building

Table of Contents

Multi-Gutter STC-MSC Taller Existing Building Multi-Gutter Downspouts Multi-Gutter End Cap and Splice Parapet Eave Steel

Parapet Steel at Bypass High Side Standard Corner Post w Back to Back Cee Post and Support Girt Parapet Steel at Bypass High Side Standard Corner Post w Single Cee Post and Support Girt Parapet Steel at Bypass High Side w Back to Back Cee Post and Support Girt Parapet Steel at Bypass High Side w Single Cee Post and Support Girt Parapet Steel at Bypass High Side w Wide Flange Post and Support Girt Parapet Steel at Bypass Low Side w Wide Flange Post Parapet Steel at Flush High Side Rotated Corner Post w Wide Flange Post and Support Girt Parapet Steel at Flush High Side w Wide Flange Post and Support Girt Parapet Steel at Flush Low Side w Wide Flange Post Parapet Steel at Inset High Side w Wide Flange Post and Support Girt Parapet Steel at Inset Low Side w Wide Flange Post Parapet Gable Steel

Parapet at Bypass Endwall w Wide Flange Post Parapet at Flush Endwall w Wide Flange Post Parapet - CS Roof Parapet at Endwall w CS

Parapet at High Side w CS - Support Girt Parapet at Low Side w CS - Multi-gutter Parapet - CS Roof w Nichiha Panel Extended Façade CS Roof Panel w Multi-gutter and Nichiha Panel Not by Chief Extended Façade CS Roof Panel w Multi-gutter and Nichiha Panel-Cap Trim Not by Chief

Parapet at Endwall w CS Roof Panel and Nichiha Panel Not by Chief Parapet at High Side w CS Roof Panel and Nichiha Panel Not by Chief Parapet at Low Side w Multi-gutter and Nichiha Panel Not by Chief Parapet - STC-MSC Roof - Eave Parapet at Low Side w STC-MSC w Multi-gutter Parapet at High Side w STC-MSC w Support Girt and Thermal Spacer Parapet - STC-MSC w Nichiha Panel - Eave Parapet at Low Side with STC-MSC Roof Panel-Multi-gutter and Nichiha Panel Not by Chief Parapet at High Side with STC-MSC Roof Panel-Support Girt Thermal Spacer and Nichiha Panel Not by Chief Parapet - STC-MSC Roof - Gable

Parapet at Endwall w STC-MSC Gable Lead End w Thermal Spacer Parapet at Endwall w STC-MSC Gable Tail End w Thermal Spacer Parapet at Endwall w STC-MSC Gable End w Field Bend Vertical Leg and Thermal Spacer Parapet - STC-MSC w Nichiha Panel - Gable Parapet at Endwall w STC-MSC Gable Lead End Thermal Spacer and Nichiha Panel NBC

Table of Contents

Parapet at Endwall w STC-MSC Gable Tail End Thermal Spacer and Nichiha Panel NBC Parapet at Endwall w STC-MSC Gable w Field Bend Leg Thermal Spacer and Nichiha Panel NBC Inset-Outset Fascia Inset-Outset Fascia-Through Column

Inset-Outset Fascia-Left Corner Wide Openings and Doors Higher Power Hydraulic Door at Inset Sidewall Wide Endwall Opening w Header Beam (Preferred) Wide Opening at Inset Endwall (Alternate) Bi-Fold Doors Bi-fold Door Cross Section

Bi-fold Door Jamb w AP Panel Bi-fold Door Jamb w CS Panel Doors at Brittle Material OHD or 3-Sided Opening in Brittle Material Wall - Jambs to FF w DST Walkdoor KD in Brittle Material Wall - Jambs to top of wall Walkdoor KD-Other in Brittle Material Wall - Jambs to FF w DST Walkdoor PA-SF in Brittle Material Wall - No Subframe w Jambs w DST

Walkdoor PA-SF in Brittle Material Wall - Subframe to FF w DST Walkdoor PA-SF in Brittle Material Wall - Subframe to top of wall Boxed in Below Eave Canopy Boxed in Below Eave Canopy Steel - Beam to Flush Column w Horizontal Soffit Purlins Boxed in Below Eave Canopy Steel - Canopy End Cee Section Support to Blocking at Building Line

Boxed in Below Eave Canopy w CS Roof Panel at Building Line and FSP Soffit Boxed in Below Eave Canopy w CS Roof Panel at Canopy End and FSP Soffit Boxed in Below Eave Canopy w CS Roof Panel-Eave Gutter and FSP Soffit

Boxed in Below Eave Canopy w CS End Panel at Inside Corner Boxed in Below Eave Canopy w AP End Panel at Inside Corner Transverse Expansion - Girts

Girt to Inset Col w 6-8 Flange at Trans Exp Girt to Inset Col w 10 Flange at Trans Exp Girt to Bypass Col w 6-8 Flange at Trans Exp Girt to Bypass Col w 10 Flange at Trans Exp

Transverse Expansion - Eave Strut at Purlin Roof Eave Strut to Col w 6-8 Flange and CS Roof Trans Exp Eave Strut to Col w 10 Flange and CS Roof Trans Exp

Eave Strut to Col w 6-8 flange and MVF-MVP Roof Trans Exp w Thermal Spacer Eave Strut to Col w 10 flange and MVF-MVP Roof Trans Exp w Thermal Spacer Eave Strut to Col w 6-8 Flange and MVF-MVP Roof Trans Exp wo Thermal Spacer Eave Strut to Col w 10 Flange and MVF-MVP Roof Trans Exp wo Thermal Spacer

Table of Contents

Eave Strut to Col w 6-8 Flange and STC-MSC Roof Trans Exp w Thermal Spacer Eave Strut to Col w 10 Flange and STC-MSC Roof Trans Exp w Thermal Spacer Eave Strut to Col w 6-8 Flange and STC-MSC Roof Trans Exp wo Thermal Spacer Eave Strut to Col w 10 Flange and STC-MSC Roof Trans Exp wo Thermal Spacer Transverse Expansion - Purlins Z-Purlin to Rafter 6-8 Flange and STC-MSC Roof Trans Exp Z-Purlin to Rafter 10 Flange and STC-MSC Roof Trans Exp Z-Purlin to Rafter 6-8 Flange and MVF-MVP Roof Trans Exp Z-Purlin to Rafter 10 Flange and MVF-MVP Roof Trans Exp Transverse Expansion - Eave Strut at Bypass Column with Roof Joists Eave Strut to Bypass Col w 6-8 flange Joist and MVF-MVP Roof Trans Exp w Thermal Spacer Eave Strut to Bypass Col w 10 flange Joist and MVF-MVP Roof Trans Exp w Thermal Spacer Eave Strut to Bypass Col w 6-8 Flange Joist and MVF-MVP Roof Trans Exp wo Thermal Spacer Eave Strut to Bypass Col w 10 Flange Joist and MVF-MVP Roof Trans Exp wo Thermal Spacer Eave Strut to Bypass Col w 6-8 Flange Joist and STC-MSC Roof Trans Exp w T-Spcr Eave Strut to Bypass Col w 10 Flange Joist and STC-MSC Roof Trans Exp w T-Spcr Eave Strut to Bypass Col w 6-8 Flange Joist and STC-MSC Roof Trans Exp wo T-Spcr Eave Strut to Bypass Col w 10 Flange Joist and STC-MSC Roof Trans Exp wo T-Spcr Transverse Expansion - Eave Strut at Inset Column with Roof Joists Eave Strut to Inset Col w 6-8 flange Joist and MVF-MVP Roof Trans Exp w Thermal Spacer Eave Strut to Inset Col w 10 flange Joist and MVF-MVP Roof Trans Exp w Thermal Spacer Eave Strut to Inset Col w 6-8 Flange Joist and MVF-MVP Roof Trans Exp wo Thermal Spacer Eave Strut to Inset Col w 10 Flange Joist and MVF-MVP Roof Trans Exp wo Thermal Spacer Eave Strut to Inset Col w 6-8 Flange Joist and STC-MSC Roof Trans Exp w T-Spcr Eave Strut to Inset Col w 10 Flange Joist and STC-MSC Roof Trans Exp w T-Spcr Eave Strut to Inset Col w 6-8 Flange Joist and STC-MSC Roof Trans Exp wo T-Spcr Eave Strut to Inset Col w 10 Flange Joist and STC-MSC Roof Trans Exp wo T-Spcr Transverse Expansion - Roof Joists Z-Purlin to Rafter 6-8 Flange and CS Roof Trans Exp Z-Purlin to Rafter 10 Flange and CS Roof Trans Exp

Short Span Joist to Rafter w 6-8 Flange Trans Exp Short Span Joist to Rafter with 10 Flange Trans Exp Long Span Joist to Rafter w 6-8 Flange Trans Exp Long Span Joist to Rafter w 10 Flange Trans Exp Transverse Expansion - Walls CS Wall Panel Expansion w J Trim Inset AP Wall Panel Expansion w J Trim Inset CS Wall Panel Expansion w J Trim Bypass AP Wall Panel Expansion w J Trim Bypass Transverse Expansion - Roof with Purlins

Table of Contents

CS Trans Exp Purlin CS Trans Exp Trim Plug Conn

MVF-MVP Exp 2.5 inch GAP 2 inch TOTAL SLIDE w T-SPCR MVF-MVP Exp 2.5 inch GAP 2 inch TOTAL SLIDE wo T-SPCR MVF-MVP Exp 3.5 inch GAP 2 inch TOTAL SLIDE w T-SPCR MVF-MVP Exp 3.5 inch GAP 2 inch TOTAL SLIDE wo T-SPCR

MVF-MVP Exp ACROSS ROOF CAP DETAIL 1 MVF-MVP Exp ACROSS ROOF CAP DETAIL 2 MVF-MVP Exp TRIM PLUG CONN FLOW LEFT

STC-MSC Exp 2.5 inch GAP 2 inch TOTAL SLIDE w T-SPCR STC-MSC Exp 2.5 inch GAP 2 inch TOTAL SLIDE wo T-SPCR STC-MSC Exp 3.5 inch GAP 2 inch TOTAL SLIDE w T-SPCR STC-MSC Exp 3.5 inch GAP 2 inch TOTAL SLIDE wo T-SPCR

STC-MSC Exp ACROSS ROOF CAP detail 1 STC-MSC Exp ACROSS ROOF CAP detail 2 STC-MSC Exp TRIM PLUG CONNECTION Transverse Expansion - Roof with Joists

MVF-MVP Exp Joist 2 inch TOTAL SLIDE w T-SPCR Joist MVF-MVP Exp Joist 2 inch TOTAL SLIDE wo T-SPCR Joist MVF-MVP Exp Joist ACROSS ROOF CAP DETAIL 1 MVF-MVP Exp Joist ACROSS ROOF CAP DETAIL 2 MVF-MVP Exp Joist TRIM PLUG CONN FLOW LEFT STC-MSC Exp Joist 2 inch TOTAL SLIDE w T-SPCR Joist STC-MSC Exp Joist 2 inch TOTAL SLIDE wo T-SPCR Joist STC-MSC Exp Joist ACROSS ROOF CAP detail 1 STC-MSC Exp Joist ACROSS ROOF CAP detail 2 STC-MSC Exp Joist TRIM PLUG CONNECTION Transverse Expansion - Existing Building by Chief MVF-MVP EXIST BLDG by CHIEF ROOF CAP DETAIL 1 MVF-MVP EXIST BLDG by CHIEF ROOF CAP DETAIL 2 MVF-MVP LT EXIST BLDG by CHIEF TRIM PLUG CONN STC-MSC EXIST BLDG by CHIEF 3 inch GAP w T-SPCR STC-MSC EXIST BLDG by CHIEF at ROOF CAP detail 1 STC-MSC EXIST BLDG by CHIEF at ROOF CAP detail 2 STC-MSC EXIST BLDG by CHIEF TRIM PLUG CONNECTION Transverse Expansion - Existing Building NOT by Chief CS ROOF PANEL to EXIST BLDG NBC CS ROOF PANEL to EXIST BLDG NBC TRIM PLUG CONN MVF-MVP EXIST BLDG by CHIEF Exist Lead w T MVF-MVP EXIST BLDG by CHIEF Exist Tail w T

Table of Contents

MVF-MVP EXIST BLDG NBC LEAD w T-SPCR MVF-MVP EXIST BLDG NBC TAIL w T-SPCR MVF-MVP EXIST BLDG NBC ROOF CAP MVF-MVP EXIST LT BLDG NBC TRIM PLUG CONN STC-MSC EXIST BLDG NBC w T-SPCR STC-MSC EXIST BLDG NBC ROOF CAP STC-MSC EXIST BLDG NBC TRIM PLUG CONN CS Roof Longitudinal Expansion Joint with Purlins CS panel 1'-0 Stepped Roof Detail w Straight DS CS panel 1'-2 Stepped Roof Detail w Straight DS CS panel Short Step Roof Detail w Straight DS Smart Canopy Smart Canopy-STC-MSC Eave Smart Canopy-STC-MSC Eave-CS-AP Ceiling Liner Smart Canopy-STC-MSC Eave-FSP Ceiling Liner Smart Canopy-STC-MSC Gable Lead-Height Change

Smart Canopy-STC-MSC Gable Lead-Height Change-AP Ceiling Liner Smart Canopy-STC-MSC Gable Lead-Height Change-CS Ceiling Liner Smart Canopy-STC-MSC Gable Lead-Height Change-Exist Bldg Smart Canopy-STC-MSC Gable Lead-Height Change-Exist Bldg-AP Ceiling Liner Smart Canopy-STC-MSC Gable Lead-Height Change-Exist Bldg-CS Ceiling Liner Smart Canopy-STC-MSC Gable Lead-Height Change-Exist Bldg-FSP Ceiling Liner Smart Canopy-STC-MSC Gable Lead-Height Change-FSP Ceiling Liner Smart Canopy-STC-MSC Gable Tail

Smart Canopy-STC-MSC Gable Tail-AP Ceiling Liner Smart Canopy-STC-MSC Gable Tail-CS Ceiling Liner Smart Canopy-STC-MSC Gable Tail-FSP Ceiling Liner Smart Canopy-STC-MSC Ridge Smart Canopy-STC-MSC Ridge-CS-AP Ceiling Liner Smart Canopy-STC-MSC Ridge-FSP Ceiling Liner Smart Canopy-MVF-MVP Eave Smart Canopy-MVF-MVP Eave-CS-AP Ceiling Liner Smart Canopy-MVF-MVP Eave-FSP Ceiling Liner Smart Canopy-MVF-MVP Gable Lead-Height Change

Smart Canopy-MVF-MVP Gable Lead-Height Change-AP Ceiling Liner Smart Canopy-MVF-MVP Gable Lead-Height Change-CS Ceiling Liner Smart Canopy-MVF-MVP Gable Lead-Height Change-Exist Bldg Smart Canopy-MVF-MVP Gable Lead-Height Change-Exist Bldg-AP Ceiling Liner Smart Canopy-MVF-MVP Gable Lead-Height Change-Exist Bldg-CS Ceiling Liner Smart Canopy-MVF-MVP Gable Lead-Height Change-Exist Bldg-FSP Ceiling Liner

Table of Contents

Smart Canopy-MVF-MVP Gable Lead-Height Change-FSP Ceiling Liner Smart Canopy-MVF-MVP Gable Tail

Smart Canopy-MVF-MVP Gable Tail-AP Ceiling Liner Smart Canopy-MVF-MVP Gable Tail-CS Ceiling Liner Smart Canopy-MVF-MVP Gable Tail-FSP Ceiling Liner Smart Canopy-MVF-MVP Ridge Smart Canopy-MVF-MVP Ridge-CS-AP Ceiling Liner Smart Canopy-MVF-MVP Ridge-FSP Ceiling Liner Smart Canopy Support Tube Column Splice

Height Change - Steel

Height Change Steel

Uphill Cut on Back-to-Back Cee Post to Top of Height Change Rafter-Left

BACK TO BACK ENDWALL POST

RAFTER BEAM (4) 1/2" X 1 1/4" BOLTS

Uphill Cut on Cee Corner Post to Top of Height Change Frame Column-Left

1

BL

CORNER POST

EAVE STRUT

(2) 5/8" X 1 1/2" BOLTS W/ (2) 5/8" HARD WASHERS ON C-SECTION SIDE

(2) 1/2" X 1 1/4" BOLTS

FRAME COLUMN

Uphill Cut on Endwall Post to Top of Height Rafter-Left

1

CL

WIDE FLANGE ENDWALL POST

(4) 1/2" X 1 1/4" BOLTS

RAFTER BEAM

Uphill Cut on Outset Corner Post to Top of Height Change Frame Column-Left

1

BL

EAVE STRUT (4) 1/2" X 1 1/4" BOLTS CORNER POST (2) 5/8" X 1 1/2" BOLTS W/ (2) 5/8" HARD WASHERS ON C-SECTION SIDE

FRAME COLUMN

Uphill Cut on Rotated Corner Post to Top of Height Change Frame Column-Left

1

BL

CORNER POST

EAVE STRUT

(2) 5/8" X 1 1/2" BOLTS W/ (2) 5/8" HARD WASHERS ON C-SECTION SIDE

(4) 1/2" X 1 1/4" BOLTS

FRAME COLUMN

Uphill Height Change Endwall Rafter Bracketed to Taller Endwall Post-Left

1

CL

ENDWALL POST

ENDWALL RAFTER BEAM

(4) 1/2" X 1 1/4" BOLTS

Uphill Height Change Endwall Rafter Bracketed to Taller Inset Sidewall Corner Post-Left

1

BL

1"

CORNER POST EAVE STRUT (2) 5/8" X 1 1/2" BOLTS W/ (2) 5/8" HARD WASHERS ON C-SECTION SIDE (4) 1/2" X 1 1/4" BOLTS ENDWALL RAFTER BEAM

Uphill Height Change Endwall Rafter Bracketed to Taller Outset Sidewall Corner Post-Left

1

BL

CORNER POST

EAVE STRUT

(2) 5/8" X 1 1/2" BOLTS W/ (2) 5/8" HARD WASHERS ON C-SECTION SIDE

(4) 1/2" X 1 1/4" BOLTS

ENDWALL RAFTER BEAM

Uphill Height Change Endwall Rafter Bracketed to Taller Rotated Corner Post-Left

1

BL

CORNER POST EAVE STRUT

(2) 5/8" X 1 1/2" BOLTS W/ (2) 5/8" HARD WASHERS ON C-SECTION SIDE

(4) 1/2" X 1 1/4" BOLTS

ENDWALL RAFTER BEAM

Height Change - Purlins

Height Change Purlins

Inset Gable Height Change w Zee Purlin-Building on Left

Outset Gable Height Change w Zee Purlin-Building on Left

1

3 3 4 "

HEIGHT CHANGE ANGLE (A-20-H)

BL

4"

#12-14 X 1" PANCAKE HEAD (2 EACH PURLIN)

PURLIN (2) 1/2" X 1 1/4" BOLTS RAFTER BEAM

Back Up Panel at Height Change - CS Roof

Back Up Panel at Height Change CS Roof

CS Height Change at Gable w Taller Backup Panel

DOUBLE BEAD TAPE MASTIC 1/4-14 X 1 1/4" WT (12" C.C.) HEIGHT CHANGE TRIM (RHT) INSIDE CLOSURE w/ TAPE MASTIC TOP & BOTTOM 1/4-14 x 1 1/4" WT (6" C.C. for CS PANEL) (12" C.C.for AP PANEL) HEIGHT CHANGE ANGLE (A-20-H) *BACK-UP PANEL

BL

PURLIN

CS ROOF PANEL

1

4 "

#12-14 X 1 1/4" (2 EACH PURLIN) (WALL COLOR)

1"

* FIELD CUT BOTTOM OF BACK-UP PANELS TO MATCH ROOF SLOPE. PROVIDE AIR GAP OF 1/4" MIN. AT BOTTOM OF PANEL TO AVOID CORROSION.

TAPE MASTIC SENT FOR BACK-UP PANEL SIDE LAPS. WARRANTY FASTENERS SENT FOR BACK-UP PANEL.

CS Height Change at High Side w Eave Strut and Taller Backup Panel

TAPE MASTIC SENT FOR BACK-UP PANEL SIDE LAPS. WARRANTY FASTENERS SENT FOR BACK-UP PANEL.

1

1/4-14 X 1 1/4" WT (6" C.C. for CS PANEL) (12" C.C. for AP PANEL) GIRT BACK-UP PANEL

BL

1/4-14 X 7/8" WT (12" C.C.) HEIGHT CHANGE TRIM (LHTC) INSIDE CLOSURE w/ TAPE MASTIC TOP & BOTTOM OUTSIDE CLOSURE (2" X 3')

1 4 " Provide air gap of 1/4" min. at bottom of panel to avoid corrosion.

1 1

2 "

CS ROOF PANEL

2 ROWS DOUBLE BEAD MASTIC TOP & BOTTOM OF OUTSIDE CLSOURE

1/4-14 X 1 1/4" WT (6" C.C.) EAVE STRUT

CS Height Change at High Side w Out Eave Strut and Taller Backup Panel

TAPE MASTIC SENT FOR BACK-UP PANEL SIDE LAPS. WARRANTY FASTENERS SENT FOR BACK-UP PANEL.

1

1/4-14 X 1 1/4" WT (6" C.C. for CS PANEL) (12" C.C. for AP PANEL) GIRT BACK-UP PANEL

BL

1/4-14 X 7/8" WT (12" C.C.) HEIGHT CHANGE TRIM (LHTC) INSIDE CLOSURE w/ TAPE MASTIC TOP & BOTTOM OUTSIDE CLOSURE (2" X 3')

1 4 " Provide air gap of 1/4" min. at bottom of panel to avoid corrosion.

1 1

2 "

CS ROOF PANEL

2 ROWS DOUBLE BEAD MASTIC TOP & BOTTOM OF OUTSIDE CLSOURE

1/4-14 X 1 1/4" WT (6" C.C.) EAVE STRUT

Back Up Panel at Height Change - STC-MSC Roof

Back Up Panel at Height Change STC-MSC Roof

STC-MSC Gable Field Bend Vertical Leg - Taller Backup Panel and Thermal Spacer

** FIELD CUT BOTTOM OF BACK-UP PANELS TO MATCH ROOF SLOPE. PROVIDE AIR GAP OF 1/4" MIN. AT BOTTOM OF PANEL TO AVOID CORROSION.

SIKA 511 CAULK IN LOCKFORM OF HEIGHT CHANGE TRIM TOP (BEFORE ASSEMBLING)

INSIDE CLOSURE w/ TAPE MASTIC TOP & BOTTOM

1

INSIDE CLOSURE

**BACK-UP PANEL

HEIGHT CHANGE TRIM TOP (GHMTF) TRI-BEAD TAPE SEALER SIKA 511 CAULK IN LOCKFORM OF HEIGHT CHANGE TRIM TOP (BEFORE ASSEMBLING) (SEE INSET DETAIL)

BL

1/4-14 X 1 1/4" WT (6" C.C. for CS PANEL) (12" C.C. for AP PANEL)

RAKE SUPPORT (A-20-T)

1/4-14 X 1 1/4" WT (12" C.C.) STC/MSC ROOF PANEL (FIELD FORM 3" VERTICAL LEG TO FIT FINAL DIMENSION)

* It is important that fasteners are installed through the center of the slotted holes of the rake support. TAPE MASTIC SENT FOR BACK-UP PANEL SIDE LAPS. WARRANTY FASTENERS SENT FOR BACK-UP PANEL.

THERMAL SPACER

(NOT BY CHIEF)

1

4 "

HEIGHT CHANGE ANGLE (A-20-H)

HEIGHT CHANGE TRIM BOTTOM (GHMBF)

2"

1/4-14 X 1 1/4" SHOULDER (24" C.C.)*

#12-14 X 1" PANCAKE HEAD (2 EACH PURLIN) PURLIN

STC-MSC Gable Lead - Taller Backup Panel and Thermal Spacer

SIKA 511 CAULK IN LOCKFORM OF HEIGHT CHANGE TRIM TOP (BEFORE ASSEMBLING)

** FIELD CUT BOTTOM OF BACK-UP PANELS TO MATCH ROOF SLOPE. PROVIDE AIR GAP OF 1/4" MIN. AT BOTTOM OF PANEL TO AVOID CORROSION.

INSIDE CLOSURE w/ TAPE MASTIC TOP & BOTTOM HEIGHT CHANGE TRIM TOP (GHMTF) TRI-BEAD TAPE SEALER

1

BL

**BACK-UP PANEL

SIKA 511 CAULK IN LOCKFORM OF HEIGHT CHANGE TRIM TOP (BEFORE ASSEMBLY) (SEE INSET DETAIL)

1/4-14 X 1 1/4" SHOULDER (24" C.C.)* RAKE SUPPORT (A-20-T) HEIGHT CHANGE ANGLE (A-20-H) 1/4-14 X 1 1/4" WT (6" C.C. for CS PANEL) (12" C.C. for AP PANEL)

1/4-14 X 1 1/4" WT (12" C.C.) STC/MSC ROOF PANEL THERMAL SPACER

(NOT BY CHIEF)

* It is important that fasteners are installed through the center of the slotted holes of the rake support. TAPE MASTIC SENT FOR BACK-UP PANEL SIDE LAPS. WARRANTY FASTENERS SENT FOR BACK-UP PANEL.

PURLIN

1

4 "

HEIGHT CHANGE TRIM BOTTOM (GHMBF)

2"

#12-14 X 1" PANCAKE HEAD (2 EACH PURLIN)

STC-MSC Gable Tail - Taller Backup Panel and Thermal Spacer

** FIELD CUT BOTTOM OF BACK-UP PANELS TO MATCH ROOF SLOPE. PROVIDE AIR GAP OF 1/4" MIN. AT BOTTOM OF PANEL TO AVOID CORROSION.

SIKA 511 CAULK IN LOCKFORM OF HEIGHT CHANGE TRIM TOP (BEFORE ASSEMBLING)

HEIGHT CHANGE TRIM TOP (GHMTF) INSIDE CLOSURE w/TAPE MASTIC TOP & BOTTOM

1

**BACK-UP PANEL 1/4-14 X 1 1/4" WT

BL

SIKA 511 CAULK IN LOCKFORM OF HEIGHT CHANGE TRIM TOP (BEFORE ASSEMBLING) (SEE INSET DETAIL) TRI-BEAD TAPE SEALER

(6" C.C. for CS PANEL) (12" C.C. for AP PANEL)

RAKE SUPPORT (A-20-T)

THERMAL SPACER STC/MSC ROOF PANEL 1/4-14 X 1 1/4" WT (12" C.C.)

* It is important that fasteners are installed through the center of the slotted holes of the rake support. TAPE MASTIC SENT FOR BACK-UP PANEL SIDE LAPS. WARRANTY FASTENERS SENT FOR BACK-UP PANEL.

(NOT BY CHIEF)

1

4 "

#12-14 X 1" PANCAKE HEAD (2 EACH PURLIN) PURLIN HEIGHT CHANGE TRIM BOTTOM (GHMBF) 1/4-14 X 1 1/4" SHOULDER (24" C.C.)*

HEIGHT CHANGE ANGLE (A-20-H)

2"

STC-MSC Gable Tail Special Term Trim - Taller Backup Panel and Thermal Spacer

* FIELD CUT BOTTOM OF BACK-UP PANELS TO MATCH ROOF SLOPE. PROVIDE AIR GAP OF 1/4" MIN. AT BOTTOM OF PANEL TO AVOID CORROSION.

SIKA 511 CAULK IN LOCKFORM OF SPECIAL TRIM TOP (SPT- ) (BEFORE ASSEMBLING)

INSIDE CLOSURE w/ TAPE MASTIC TOP & BOTTOM SPECIAL TRIM (SPT- ) TRI-BEAD TAPE MASTIC

BL

*BACK-UP PANEL

SEKA 511 CAULK IN LOCKFORM OF SPECIAL TRIM TOP (SPT- ) (BEFORE ASSEMBLING) (SEE INSET DETAIL) 1/4-14 X 1 1/4" WT (12" C.C. AND FASTEN THROUGH CLIP)

#12-14 X 1" PANCAKE HEAD (2 EACH PURLIN) 1/4-14 X 1 1/4" WT (6" C.C. for CS PANEL) (12" C.C. for AP PANEL)

THERMAL SPACER STC/MSC ROOF PANEL

1

4 "

HEIGHT CHANGE ANGLE (A-20-H)

(NOT BY CHIEF)

HEIGHT CHANGE TRIM BOTTOM (GHMBF)

Tape mastic sent for back-up panel side laps. Warranty fasteners sent for back-up panel.

PANEL CLIP

PURLIN

STC-MSC High Side - Taller Backup Panel and Thermal Spacer

1/4-14 X 1 1/4" WT (6" C.C. for CS PANEL) (12" C.C. for AP PANEL) INSIDE CLOSURE w/ TAPE MASTIC TOP & BOTTOM

BL

**TRI-BEAD TAPE MASTIC OUTSIDE CLOSURE 1/4-14 X 1 1/4" WT (9 PER PANEL) TRI-BEAD TAPE MASTIC *1/4-14 X 7/8" WT HEIGHT CHANGE TRIM (LHET)

HEIGHT CHANGE GIRT BACK-UP PANEL

Provide air gap of 1/4" min. at bottom of panel to avoid corrosion.

1

4 "

Tape mastic sent for back-up panel side laps. Warranty fasteners sent for back-up panel.

* For screw spacing refer to High Eave Height Change Trim detail in the MSC/STC Roof Panel Erection Manual. ** 24" STC - Pre-Cut Tri-Bead Tape Mastic. 24" MSC - Tri-Bead Tape Mastic from roll. 18" MSC/STC - Tri-Bead Tape Mastic from roll.

STC/MSC ROOF PANEL

PANEL CLIP W/ FASTENERS (SEE ROOF PANEL PLAN)

(NOT BY CHIEF)

THERMAL SPACER PURLIN BACK-UP PLATE

4"

8"

Back Up Panel at Height Change - MVF-MVP Roof

Back Up Panel at Height Change MVF-MVP Roof

MVF-MVP Height Change at Gable Lead End w Taller Backup Panel and Thermal Spacer

* FIELD CUT BOTTOM OF BACK-UP PANELS TO MATCH ROOF SLOPE. PROVIDE AIR GAP OF 1/4" MIN. AT BOTTOM OF PANEL TO AVOID CORROSION.

HEIGHT CHANGE TRIM TOP (GHVT)

TAPE MASTIC SENT FOR BACK-UP PANEL SIDE LAPS. WARRANTY FASTENERS SENT FOR BACK-UP PANEL.

MVF/MVP ROOF PANEL DOUBLE BEAD TAPE MASTIC 1/4-14 X 7/8" WT (12" C.C.)** TAPE MASTIC HEIGHT CHANGE TRIM BOTTOM (GHVB) (2) #12-14 X 1 1/4" (EACH CLIP) WALL COLOR

*BACK-UP PANEL INSIDE CLOSURE w/ TAPE MASTIC TOP & BOTTOM 1/4-14 X 1 1/4" WT

BL

(6" C.C. for CS PANEL) (12" C.C. for AP PANEL)

(NOT BY CHIEF)

THERMAL SPACER

1

4 "

PANEL CLIP w/FASTENERS (REFER TO ROOF PANEL PLAN)

PANEL CLIP RAKE ANGLE (A-20-L) #12-14 X 1 1/4" (2 EACH PURLIN) (WALL COLOR)

1"

(2) #12-14 X 1 1/4"

**NOTE: This fastener must not hit the purlin.

PURLIN

MVF-MVP Height Change at Gable Tail End w Taller Backup Panel and Thermal Spacer

* FIELD CUT BOTTOM OF BACK-UP PANELS TO MATCH ROOF SLOPE. PROVIDE AIR GAP OF 1/4" MIN. AT BOTTOM OF PANEL TO AVOID CORROSION.

DOUBLE BEAD TAPE MASTIC 1/4-14 X 1 1/4" WT (12" C.C.)** DOUBLE BEAD TAPE MASTIC HEIGHT CHANGE TRIM BOTTOM (GHVB) HEIGHT CHANGE TRIM TOP (GHVT) (2) #12-14 X 1 1/4" (EACH CLIP) WALL COLOR ROOF PANEL CUT BACK DIM. CLIP LOCATION FROM B L TAPE MASTIC

TAPE MASTIC SENT FOR BACK-UP PANEL SIDE LAPS. WARRANTY FASTENERS SENT FOR BACK-UP PANEL.

BL

*BACK-UP PANEL INSIDE CLOSURE w/ TAPE MASTIC TOP & BOTTOM 1/4-14 X 1 1/4" WT

2 1 4 "

1 1 2 "

(6" C.C. for CS PANEL) (12" C.C. for AP PANEL)

MVF/MVP ROOF PANEL RAKE ANGLE (A-20-B)

PANEL CLIP w/FASTENERS (REFER TO ROOF PANEL PLAN)

1

4 "

RAKE ANGLE (A-20-L)

#12-14 X 1 1/4" (2 EACH PURLIN) (WALL COLOR) PANEL CLIP w/ FASTENERS (REFER TO ROOF PANELING PLAN)

(NOT BY CHIEF)

THERMAL SPACER

**NOTE: This fastener must not hit the purlin.

PURLIN

MVF-MVP Height Change at High Side w Taller Backup Panel and Thermal Spacer

EXPANSION TRIM (LHET) 1/4-14 X 1 1/4" WT (6" C.C. for CS PANEL) (12" C.C. for AP PANEL) INSIDE CLOSURE w/ TAPE MASTIC TOP & BOTTOM

1

BL

1/4-14 X 7/8" WT (6" C.C.)

GIRT BACK-UP PANEL

DOUBLE BEAD TAPE MASTIC

RIDGE CLOSURE

PANEL CLIP w/ FASTENERS (REFER TO ROOF PANEL PLAN)

MVF/MVP ROOF PANEL

1 4 " Provide air gap of 1/4" min. at bottom of panel to avoid corrosion.

3"

PURLIN DOUBLE BEAD TAPE MASTIC 1/4-14 X 7/8" WT (7 PER PANEL) THERMAL SPACER

(NOT BY CHIEF)

TAPE MASTIC SENT FOR BACK-UP PANEL SIDE LAPS. WARRANTY FASTENERS SENT FOR BACK-UP PANEL.

MVF-MVP Height Change w Cut Roof Panel at Gable Lead End - Taller Backup Panel and Thermal Spacer

* FIELD CUT BOTTOM OF BACK-UP PANELS TO MATCH ROOF SLOPE. PROVIDE AIR GAP OF 1/4" MIN. AT BOTTOM OF PANEL TO AVOID CORROSION.

ROOF PANEL CUT BACK DIM. CLIP LOCATION FROM B

L

HEIGHT CHANGE TRIM BOTTOM (GHVB) HEIGHT CHANGE TRIM TOP (GHVT)

TAPE MASTIC SENT FOR BACK-UP PANEL SIDE LAPS. WARRANTY FASTENERS SENT FOR BACK-UP PANEL.

BL

TAPE MASTIC

*BACK-UP PANEL INSIDE CLOSURE w/TAPE MASTIC TOP & BOTTOM 1/4-14 X 1 1/4" WT

DOUBLE BEAD TAPE MASTIC 1/4-14 X 1 1/4" WT (12" C.C.)** DOUBLE BEAD TAPE MASTIC (2) #12-14 X 1 1/4" (EACH CLIP) WALL COLOR

2 1 4 "

1 1 2 "

(6" C.C. for CS PANEL) (12" C.C. for AP PANEL)

MVF/MVP ROOF PANEL RAKE ANGLE (A-20-B)

PANEL CLIP w/FASTENERS (REFER TO ROOF PANEL PLAN)

1

4 "

PANEL CLIP RAKE ANGLE (A-20-L) #12-14 X 1 1/4" (2 EACH PURLIN) (WALL COLOR)

THERMAL SPACER

(NOT BY CHIEF)

PURLIN

(2) #12-14 X 1 1/4"

**NOTE: This fastener must not hit the purlin.

Multi-Gutter

Multi-Gutter

Multi-Gutter CS Same Height Existing Building

1

1

L EXIST. B

BL

* MULTI-GUTTER (MG- ) EXISTING ROOF PANEL (NOT BY CHIEF)

INSIDE CLOSURE WITH MASTIC TOP AND BOTTOM

CS ROOF PANEL EAVE STRUT

DRAFTING: INVESTIGATE THE ERECTABILITY OF THIS MULTI-GUTTER FOR YOUR PROJECT

1/4-14 X 1 1/4" WT (4" C.C.)

FRAME COLUMN

EXISTING BUILDING

BUILDING LINE TO BUILDING LINE

* Refer to the Multi-Gutter Endcap and Splice detail for installation This run of multi-gutter uses (2) MGEC- as endcaps

Multi-Gutter CS Sidewall between Same Height Buildings

1

1

BL

BL

MULTI-GUTTER (MG- )

INSIDE CLOSURE WITH MASTIC TOP AND BOTTOM

CS ROOF PANEL EAVE STRUT

1/4-14 X 1 1/4" WT (4" C.C.)

FRAME COLUMN

BUILDING LINE TO BUILDING LINE

* Refer to the Multi-Gutter Endcap and Splice detail for installation This run of Multi-Gutter uses (2) MGEC- as endcaps

Multi-Gutter CS Taller Building

1

1

BL

BL

WALL PANEL

GIRT

#12-14 X 1 1/4" (6" C.C. for CS PANEL) (12" C.C. for AP PANEL) INSIDE CLOSURE w/ TAPE MASTIC TOP & BOTTOM

INSIDE CLOSURE WITH MASTIC TOP AND BOTTOM

CS ROOF PANEL EAVE STRUT

1/4-14 X 1 1/4" WT (4" C.C.)

FRAME COLUMN

* MULTI-GUTTER (MG- )

BUILDING LINE TO BUILDING LINE

* Refer to the Multi-Gutter Endcap and Splice detail for installation This run of multi-gutter uses (2) MGEC- as endcaps

Multi-Gutter CS Taller Existing Building

1

1

L EXIST. B

BL

COUNTER FLASHING, FASTENER AND CAULKING (NOT BY CHIEF)

* MULTI-GUTTER (MG- )

INSIDE CLOSURE WITH MASTIC TOP AND BOTTOM

CS ROOF PANEL EAVE STRUT

1/4-14 X 1 1/4" WT (4" C.C.)

EXISTING BUILDING

FRAME COLUMN

BUILDING LINE TO BUILDING LINE

* Refer to the Multi-Gutter Endcap and Splice detail for installation This run of multi-gutter uses (2) MGEC- as endcaps

Multi-Gutter MVF-MVP Same Height Existing Building

1

1

1/4-14 X 1 1/4" WT (4 PER PANEL)

L EXIST. B

BL

EXISTING ROOF PANEL (NOT BY CHIEF)

"PIG TAIL" TAPE MASTIC (BETWEEN PANELS)

DOUBLE BEAD TAPE MASTIC MVF/MVP ROOF PANEL

DRAFTING: INVESTIGATE THE ERECTABILITY OF THIS MULTI-GUTTER FOR YOUR PROJECT

EAVE STRUT

FRAME COLUMN

* MULTI-GUTTER (MG- )

EXISTING BUILDING

BUILDING LINE TO BUILDING LINE

* Refer to the Multi-Gutter Endcap and Splice detail for installation This run of multi-gutter uses (2) MGEC- as end caps.

Multi-Gutter MVF-MVP Same Height Buildings

1

1

1/4-14 X 1 1/4" WT (4 PER PANEL)

BL

BL

"PIG TAIL" TAPE MASTIC (BETWEEN PANELS)

DOUBLE BEAD TAPE MASTIC MVF/MVP ROOF PANEL

EAVE STRUT

FRAME COLUMN

* MULTI-GUTTER (MG- )

BUILDING LINE TO BUILDING LINE

* Refer to the Multi-Gutter Endcap and Splice detail for installation This run of multi-gutter uses (2) MGEC- as end caps.

Multi-Gutter MVF-MVP Taller Building

1

1

BL

BL

#12-14 X 1 1/4" (6" C.C. for CS PANEL) (12" C.C. for AP PANEL) INSIDE CLOSURE w/ TAPE MASTIC TOP & BOTTOM

WALL PANEL

1/4-14 X 1 1/4" WT (4 PER PANEL)

GIRT

"PIG TAIL" TAPE MASTIC (BETWEEN PANELS)

DOUBLE BEAD TAPE MASTIC MVF/MVP ROOF PANEL

EAVE STRUT

* MULTI-GUTTER (MG- ) FRAME COLUMN

BUILDING LINE TO BUILDING LINE

* Refer to the Multi-Gutter Endcap and Splice detail for installation This run of multi-gutter uses (2) MGEC- as end caps.

Multi-Gutter MVF-MVP Taller Existing Building

1

1

L EXIST. B

BL

COUNTER FLASHING, FASTENER AND CAULKING (NOT BY CHIEF)

1/4-14 X 1 1/4" WT (4 PER PANEL)

"PIG TAIL" TAPE MASTIC (BETWEEN PANELS)

DOUBLE BEAD TAPE MASTIC MVF/MVP ROOF PANEL

EAVE STRUT

EXISTING BUILDING

* MULTI-GUTTER (MG- ) FRAME COLUMN

BUILDING LINE TO BUILDING LINE

* Refer to the Multi-Gutter Endcap and Splice detail for installation This run of multi-gutter uses (2) MGEC- as end caps.

Multi-Gutter STC-MSC Same Height Buildings

1

1

METAL INSIDE CLOSURE TRI-BEAD TAPE SEALER 1/4-14 X 1 1/4" WT PANEL (8 PER PANEL)

BL

BL

EAVE STRUT STC/MSC ROOF PANEL TRI-BEAD TAPE SEALER

1/4-14 X 1" (2) PER CLOSURE

FRAME COLUMN

* MULTI-GUTTER (MG- )

BUILDING LINE TO BUILDING LINE

* Refer to the Multi-Gutter Endcap and Splice detail for installation This run of multi-gutter uses (2) MGEC- as end caps.

Multi-Gutter STC-MSC Same Height Existing Building

1

1

METAL INSIDE CLOSURE TRI-BEAD TAPE SEALER 1/4-14 X 1 1/4" WT PANEL (8 PER PANEL)

L EXIST. B

BL

EXISTING ROOF PANEL (NOT BY CHIEF)

1/4-14 X 1" (2) PER CLOSURE EAVE STRUT STC/MSC ROOF PANEL TRI-BEAD TAPE SEALER

DRAFTING: INVESTIGATE THE ERECTABIL TY OF HIS MULTI-GUTTER FOR YOUR PROJECT

FRAME COLUMN

* MULTI-GUTTER (MG- )

EXISTING BUILDING

BUILDING LINE TO BUILDING LINE

* Refer to the Multi-Gutter Endcap and Splice detail for installation This run of multi-gutter uses (2) MGEC- as end caps.

Multi-Gutter STC-MSC Taller Building

1

1

TRI-BEAD TAPE SEALER 1/4-14 X 1 1/4" WT PANEL (8 PER PANEL) INSIDE CLOSURE w/ TAPE MASTIC TOP & BOTTOM #12-14 X 1 1/4" (6" C.C. for CS PANEL) (12" C.C. for AP PANEL)

BL

BL

WALL PANEL

GIRT

STC/MSC ROOF PANEL METAL INSIDE CLOSURE

EAVE STRUT

TRI-BEAD TAPE SEALER

1/4-14 X 1" (2) PER CLOSURE

FRAME COLUMN

* MULTI-GUTTER (MG- )

BUILDING LINE TO BUILDING LINE

* Refer to the Multi-Gutter Endcap and Splice detail for installation This run of multi-gutter uses (2) MGEC- as end caps.

Multi-Gutter STC-MSC Taller Existing Building

1

1

L EXIST. B

BL

COUNTER FLASHING, FASTENER AND CAULKING (NOT BY CHIEF) METAL INSIDE CLOSURE TRI-BEAD TAPE SEALER 1/4-14 X 1 1/4" WT PANEL (8 PER PANEL)

STC/MSC ROOF PANEL

EAVE STRUT

1/4-14 X 1" (2) PER CLOSURE TRI-BEAD TAPE SEALER

EXISTING BUILDING

FRAME COLUMN

* MULTI-GUTTER (MG- )

BUILDING LINE TO BUILDING LINE

* Refer to the Multi-Gutter Endcap and Splice detail for installation This run of multi-gutter uses (2) MGEC- as end caps.

Multi-Gutter Downspouts

Reference notes: ·

NOTE: CHIEF BUILDINGS recommends that the multi-gutter be lined with material suitable for weather related exposure. CHIEF BUILDINGS primer is for temporary protection only.

All sealant is SikaLastomer ® -511.

· Seal gutter insert to gutter with a 3/8" bead of sealant around flanges of insert. Hand tool into place upon installation to minimize damning effect. · Field cut holes in multi-gutter for downspouts

DOWNSPOUT INSERT

MULTI-GUTTER

SEALANT

CUT LINE

(3) 1/8" X 3/8" BLIND RIVET DOWNSPOUT

DOWNSPOUT BY CHIEF TO MULTI-GUTTER

Multi-Gutter End Cap and Splice

NOTE: CHIEF BUILDINGS recommends that the multi-gutter be lined with material suitable for weather related exposure. CHIEF BUILDINGS primer is for temporary protection only.

MULTI-GUTTER (MG)

END CAP (MGEC)

BUTT WELD

MULTI-GUTTER (MG)

FILLET WELD

MULTI-GUTTER END CAP AND SPLICE

Parapet Eave Steel

Parapet Eave Steel

Parapet Steel at Bypass High Side Standard Corner Post w Back to Back Cee Post and Support Girt

1

1 1 2 "

BL

BACK-TO-BACK C-SECTION PARAPET POST

XXX'-X"

HEIGHT CHANGE GIRT

PARAPET GIRT (4) 1/2" X 1 1/4" BOLTS

EAVE STRUT (2) 5/8" X 1 1/2" BOLTS W/ (2) 5/8" HARDENED WASHERS ON C-SECTION SIDE

XXX'-X"

CONTINUOUS PURLIN (2) 1/2" X 1 1/4" BOLTS

(4) 1/2" X 1 1/4" BOLTS (TYP)

GIRT

XXX'-X"

(4) 3/4" X 2" BOLTS W/ (4) 3/4" HARDENED WASHERS ON C-SECTION SIDE

(6) 1/2" X 1 1/4" BOLTS ENDWALL RAFTER BEAM

CORNER POST

Parapet Steel at Bypass High Side Standard Corner Post w Single Cee Post and Support Girt

1

1 1 2 "

BL

SINGLE C-SECTION PARAPET POST

XXX'-X"

XBC-84

PARAPET GIRT (4) 1/2" X 1 1/4" BOLTS

EAVE STRUT (2) 5/8" X 1 1/2" BOLTS W/ (2) 5/8" HARDENED WASHERS ON C-SECTION SIDE HEIGHT CHANGE GIRT

XXX'-X"

CONTINUOUS PURLIN (2) 1/2" X 1 1/4" BOLTS

(4) 1/2" X 1 1/4" BOLTS (TYP)

GIRT

XXX'-X"

XBC-3 (TYP)

(6) 1/2" X 1 1/4" BOLTS ENDWALL RAFTER BEAM

(4) 3/4" X 2" BOLTS W/ (4) 3/4" HARDENED WASHERS ON C-SECTION SIDE

CORNER POST

Parapet Steel at Bypass High Side w Back to Back Cee Post and Support Girt

1

1 1 2 "

BL

XXX'-X"

(4) 1/2" X 1 1/4" BOLTS (4) 1/2" X 1 1/4" BOLTS (TYP)

HEIGHT CHANGE GIRT PARAPET GIRT

XXX'-X"

EAVE STRUT (4) 5/8" X__" BOLTS W/(4) 5/8" HARD WASHERS AT C-SECTION SIDE

BACK-TO-BACK C-SECTION PARAPET POST

CONTINUOUS PURLIN (6) 1/2" X 1 1/4" BOLTS

HIGH SIDE FRAME COLUMN

GIRT

XXX'-X"

(4) 3/4" X 2" BOLTS W/ (4) 3/4" HARDENED WASHERS ON C-SECTION SIDE

Parapet Steel at Bypass High Side w Single Cee Post and Support Girt

1

1 1 2 "

BL

XXX'-X"

PARAPET GIRT

(6) 1/2" X 1 1/4" BOLTS

SINGLE C-SECTION PARAPET POST

(1) XBC-84 EACH SIDE

HEIGHT CHANGE GIRT

XXX'-X"

EAVE STRUT (4) 5/8" X__" BOLTS W/(4) 5/8" HARD WASHERS AT C-SECTION SIDE

(6) 1/2" X 1 1/4" BOLTS (TYP)

CONTINUOUS PURLIN (6) 1/2" X 1 1/4" BOLTS

XBC-3 THIS SIDE, XBC-84 OTHER SIDE (TYP)

HIGH SIDE FRAME COLUMN

GIRT

XXX'-X"

(4) 3/4" X 2" BOLTS W/ (4) 3/4" HARDENED WASHERS ON C-SECTION SIDE

Parapet Steel at Bypass High Side w Wide Flange Post and Support Girt

1

1 1 2 "

BL

XXX'-X"

(6) 1/2" X 1 1/4" BOLTS

PARAPET GIRT PARAPET POST

(1) XBC-85 EACH SIDE

HEIGHT CHANGE GIRT

XXX'-X"

EAVE STRUT (4) 5/8" X__" BOLTS W/(4) 5/8" HARD WASHERS AT C-SECTION SIDE

(6) 1/2" X 1 1/4" BOLTS (TYP)

CONTINUOUS PURLIN (6) 1/2" X 1 1/4" BOLTS

(1) XBC-74 EACH SIDE, (TYP)

HIGH SIDE FRAME COLUMN

GIRT

XXX'-X"

(4) __" X __" BOLTS

Parapet Steel at Bypass Low Side w Wide Flange Post

1

1 1 2 "

BL

PARAPET GIRT

XXX'-X"

(1) XBC-85 EACH SIDE

(6) 1/2" X 1 1/4" BOLTS

PARAPET POST

NOTE: CHIEF BUILDINGS RECOMMENDS THAT THE MULTI-GUTTER BE LINED WITH MATERIAL SUITABLE FOR WEATHER RELATED EXPOSURE. CHIEF BUILDINGS PRIMER IS FOR TEMPORARY PROTECTION ONLY.

(6) 1/2" X 1 1/4" BOLTS

(1) XBC-74 EACH SIDE

EAVE STRUT (4) 5/8" X 1 1/2" BOLTS W/ (4) 5/8" HARD WASHERS AT C-SECTION SIDE

XXX'-X"

HEIGHT CHANGE GIRT MULTIGUTTER (MG-X)

(4) ___" x ___" BOLTS

FRAME COLUMN

Parapet Steel at Flush High Side Rotated Corner Post w Wide Flange Post and Support Girt

1

(4) 1/2" X 1 1/4" BOLTS

BL

1 1 2 "

XXX'-X"

PARAPET GIRT

XBC-85

PARAPET POST

(4) 1/2" X 1 1/4" BOLTS (TYP)

HEIGHT CHANGE GIRT

XXX'-X"

EAVE STRUT

CONTINUOUS PURLIN (6) 1/2" X 1 1/4" BOLTS

XBC-74 (TYP)

(4) __" X __" BOLTS

ENDWALL RAFTER

(2) 5/8" X 1 1/2" BOLTS W/ (2) 5/8" HARD WASHERS AT C-SECTION SIDE

XXX'-X"

(4) 1/2" X 1 1/4" BOLTS

CORNER POST

1'-2"

Parapet Steel at Flush High Side w Wide Flange Post and Support Girt

1

1 1 2 "

BL

XXX'-X"

PARAPET POST

(6) 1/2" X 1 1/4" BOLTS PARAPET GIRT (1) XBC-85 EACH SIDE

HEIGHT CHANGE GIRT

(1) XBC-74 EACH SIDE, (TYP)

(4) 5/8" X__" BOLTS W/(4) 5/8" HARD WASHERS AT C-SECTION SIDE EAVE STRUT

XXX'-X"

(6) 1/2" X 1 1/4" BOLTS

(6) 1/2" X 1 1/4" BOLTS PURLIN

(4) __" X __" BOLTS

HIGH SIDE FRAME COLUMN

(6) 1/2" X 1 1/4" BOLTS

XXX'-X"

GIRT

Parapet Steel at Flush Low Side w Wide Flange Post

1

1 1 2 "

PARAPET GIRT

BL

XXX'-X"

(1) XBC-85 EACH SIDE

(6) 1/2" X 1 1/4" BOLTS

PARAPET POST

NOTE: CHIEF BUILDINGS RECOMMENDS THAT THE MULTI-GUTTER BE LINED WITH MATERIAL SUITABLE FOR WEATHER RELATED EXPOSURE. CHIEF BUILDINGS PRIMER IS FOR TEMPORARY PROTECTION ONLY.

(6) 1/2" X 1 1/4" BOLTS

(1) XBC-74 EACH SIDE

EAVE STRUT (4) 5/8" X 1 1/2" BOLTS W/ (4) 5/8" HARD WASHERS AT C-SECTION SIDE

XXX'-X"

HEIGHT CHANGE GIRT MULTIGUTTER (MG-X)

(4) ___" x ___" BOLTS

FRAME COLUMN

Parapet Steel at Inset High Side w Wide Flange Post and Support Girt

1

1 1 2 "

BL

XXX'-X"

PARAPET POST

PARAPET GIRT (1) XBC-85 EACH SIDE

HEIGHT CHANGE GIRT

(1) XBC-74 EACH SIDE, (TYP)

(6) 1/2" X 1 1/4" BOLTS

(4) 5/8" X__" BOLTS W/ (4) 5/8" HARD WASHERS AT C-SECTION SIDE EAVE STRUT

XXX'-X"

(6) 1/2" X 1 1/4" BOLTS

(6) 1/2" X 1 1/4" BOLTS PURLIN

(4) __" X __" BOLTS

HIGH SIDE FRAME COLUMN

(6) 1/2" X 1 1/4" BOLTS

1"

XXX'-X"

GIRT

Parapet Steel at Inset Low Side w Wide Flange Post

1

1 1 2 "

BL

XXX'-X"

PARAPET GIRT

(1) XBC-85 EACH SIDE

(6) 1/2" X 1 1/4" BOLTS

PARAPET POST

NOTE: CHIEF BUILDINGS RECOMMENDS THAT THE MULTI-GUTTER BE LINED WITH MATERIAL SUITABLE FOR WEATHER RELATED EXPOSURE. CHIEF BUILDINGS PRIMER IS FOR TEMPORARY PROTECTION ONLY.

(6) 1/2" X 1 1/4" BOLTS

(1) XBC-74 EACH SIDE

EAVE STRUT (4) 5/8" X 1 1/2" BOLTS W/ (4) 5/8" HARD WASHERS AT C-SECTION SIDE

XXX'-X"

HEIGHT CHANGE GIRT MULTIGUTTER (MG-X) (4) ____" x ____" BOLTS

FRAME COLUMN

1"

Parapet Gable Steel

Parapet Gable Steel

Parapet at Bypass Endwall w Wide Flange Post

SEE ROOF FRAMING PLAN FOR ENDWALL RAFTER TO PURLIN FLANGE BRACE REQUIREMENTS.

1

1 1 2 "

BL

XXX'-X"

PARAPET GIRT

(1) XBC-85 EACH SIDE

PARAPET POST

(6) 1/2" X 1 1/4" BOLTS

PURLIN (2) 1/2" X 1 1/4" BOLTS

1'-0" or 1'-2"

1 4 "

ENDWALL RAFTER

GIRT

(6) 1/2" X 1 1/4" BOLTS

(4) 1/2" X 1 1/4" BOLTS

(4) __" X __" BOLTS

XXX'-X"

(1) XBC-74 EACH SIDE

ENDWALL POST

Parapet at Flush Endwall w Wide Flange Post

1

SEE ROOF FRAMING PLAN FOR ENDWALL RAFTER TO PURLIN FLANGE BRACE REQUIREMENTS.

1 1 2 "

BL

XXX'-X"

(6) 1/2" X 1 1/4" BOLTS

PARAPET GIRT

(1) XBC-85 EACH SIDE

GIRT (1) XBC-74 EACH SIDE

(6) 1/2" X 1 1/4" BOLTS

PURLIN (2) 1/2" X 1 1/4" BOLTS

1'-0" or 1'-2"

1 4 "

ENDWALL RAFTER

(4) 1/2" X 1 1/4" BOLTS

PARAPET/ ENDWALL POST

Parapet - CS Roof

Parapet CS Roof

Parapet at Endwall w CS

HORIZONTAL LEG OF PARAPET CAP TRIM

#12-14 X 1 1/4" (24" C.C.)

* NOTE: REFER TO ISOMETRIC PARAPET FACADE CAP TRIM SPLICE DETAIL FOR INSTALLATION

PARAPET TRIM CAP (PCT-X)

* PARAPET CLEAT (PCC-X)

BL

#12-14 X 1" PANCAKE HEAD (12" C.C.)

PARAPET GIRT

OUTSIDE CLOSURE 1/4-14 X 7/8" WT (12" C.C.) **BACK-UP PANEL

XXX'-X"

TAPE MASTIC SENT FOR BACK-UP PANEL SIDE LAPS. WARRANTY FASTENERS SENT FOR BACK-UP PANEL.

#12-14 X 1 1/4" (6" C.C. for CS PANEL) (12" C.C. for AP PANEL) OUTSIDE CLOSURE

CS ROOF PANEL DOUBLE BEAD TAPE MASTIC 1/4 - 14 X 1 1/4" WT (12" C.C.) HEIGHT CHANGE TRIM (RHT-X) INSIDE CLOSURE w/ TAPE MASTIC TOP & BOTTOM

PARAPET/WALL PANEL

1/4-14 X 1 1/4" WT (6" C.C.)

HEIGHT CHANGE ANGLE (A-20-H)

** FIELD CUT BOTTOM OF BACK-UP PANELS TO MATCH ROOF SLOPE. PROVIDE AIR GAP OF 1/4" MIN. AT BOTTOM OF PANEL TO AVOID CORROSION.

1

4 "

1"

1 4 "

#12 - 14 X 1 1/4" (2 EACH PURLIN) (WALL COLOR)

Parapet at High Side w CS - Support Girt

* NOTE: REFER TO ISOMETRIC PARAPET FACADE CAP TRIM SPLICE DETAIL FOR INSTALLATION

PARAPET GIRT PARAPET CAP TRIM (PCT-X) 1/4-14 X 1 1/4" WT (6" C.C.) OUTSIDE CLOSURE 1/4-14 X 7/8" WT (12" C.C.) Provide air gap of 1/4" min. at bottom of panel to avoid corrosion.

1

BL

* PARAPET CLEAT (PCC-X) #12-14 X 1 1/4" (24" C.C.)

TAPE MASTIC SENT FOR BACK-UP PANEL SIDE LAPS. WARRANTY FASTENERS SENT FOR BACK-UP PANEL.

XXX'-X"

BACKUP PANEL

INSIDE CLOSURE w/ TAPE MASTIC TOP & BOTTOM HEIGHT CHANGE TRIM (LHTC) 1/4-14 X 7/8" WT (12" C.C.) 1/4-14 X 1 1/4" WT (6" C.C.) OUTSIDE CLOSURE (2" X 3') 2 ROWS DOUBLE BEAD MASTIC TOP & BOTTOM OF OUTSIDE CLOSURE

#12-14 X 1" PANCAKE HEAD (12" C.C.)

#12-14 X 1 1/4" (6" C.C. for CS PANEL) (12" C.C. for AP PANEL) OUTSIDE CLOSURE

XXX'-X"

DRAFTING USE ONLY: REMOVE EAVE STRUT OR PURLIN W/CORRESPONDING FASTENER AS REQUIRED.

PARAPET/WALL PANEL

1

4 "

CS ROOF PANEL

1 1 2 "

HEIGHT CHANGE GIRT

1/4 -14 X 1 1/4" WT (6"C.C.)

1/4-14 X 1 1/4" WT (6" C.C.) PURLIN

EAVE STRUT

Parapet at Low Side w CS - Multi-gutter

* NOTE: REFER TO ISOMETRIC PARAPET FACADE CAP TRIM SPLICE DETAIL FOR INSTALLATION

1

INSIDE CLOSURE w/ TAPE MASTIC TOP & BOTTOM 1/4 -14 X 1 1/4" WT (6" C.C.) BACKUP PANEL 1/4 - 14 X 7/8" WT (12" C.C.) 1/4 -14 X 1 1/4" WT (6" C.C.) PARAPET GIRT OUTSIDE CLOSURE

#12-14 X 1 1/4" (24" C.C.)

BL

PARAPET CAP TRIM (PCT-X) * PARAPET CLEAT (PCC-X)

XXX'-X"

TAPE MASTIC SENT FOR BACK-UP PANEL SIDE LAPS. WARRANTY FASTENERS SENT FOR BACK-UP PANEL.

#12 - 14 X 1" PANCAKE HEAD (12"C.C)

PARAPET/WALL PANEL

INSIDE CLOSURE W/ MASTIC TOP & BOTTOM

XXX'-X"

GIRT #12-14 X 1 1/4" (12" C.C.) #12-14 X 1 1/4" (6" C.C. for CS PANEL) (12" C.C. for AP PANEL)

1/4 - 14 X 1 1/4" WT (4" C.C.) CS ROOF PANEL

** MULTI-GUTTER (MG-X) EAVE STRUT

** Refer to the Multi-Gutter Endcap and Splice detail for installation This run of multi-gutter uses (2) MGEC- as endcaps

Parapet - CS Roof w Nichiha Panel

Parapet CS Roof w Nichiha Panel

Extended Façade CS Roof Panel w Multi-gutter and Nichiha Panel Not by Chief

HORIZONTAL LEG OF FASCIA CAP TRIM

TAPE MASTIC SENT FOR BACK-UP PANEL SIDE LAPS. WARRANTY FASTENERS SENT FOR BACK-UP PANEL.

1

DRAFTING: DIMENSION HORIZ. LEG OF CAP TRIM. HAVE PM VERIFY DIM. WITH BLDR.

BL

X"

X'-X"

#12-14 X 1 1/4" (24" C.C.)

INSIDE CLOSURE w/ TAPE MASTIC TOP AND BOTTOM 1/4-14 X 1 1/4" WT (6" C.C.) BACKUP PANEL 1/4-14 X 7/8" WT (12" C.C.) 1/4-14 X 1 1/4" WT (6" C.C.) FACADE GIRT OUTSIDE CLOSURE

X

SPECIAL CAP TRIM (SPT-X)

** SPECIAL CLEAT (SPT-X)

XXX'-X"

#12-14 X 1 1/4" (CS - 6" C.C.)(AP - 12" C.C.) PANCAKE HEAD FASTENER (NOT BY CHIEF) (12"C.C) SPECIAL PURCHASED (IF BY CHIEF)

INSIDE CLOSURE W/ MASTIC TOP & BOTTOM

GIRT

XXX'-X"

1/4-14 X 1 1/4" WT (4" C.C.) CS ROOF PANEL

* _" NICHIHA PANEL (NOT BY CHIEF) #12-14 X 1 1/4" (6" C.C. for CS PANEL) (12" C.C. for AP PANEL)

#12-14 X 1 1/4" (CS - 6" C.C.)(AP - 12" C.C.)

EAVE STRUT

FASCIA PANEL

* _" NICHIHA PANEL (NOT BY CHIEF) WALL PANEL

*** MULTI-GUTTER (MG-X)

* NOTE: CONNECTION OF NICHIHA PANELS (NOT BY CHIEF), TO WALL PANEL IS NOT BY CHIEF.

** NOTE: REFER TO ISOMETRIC PARAPET FACADE CAP TRIM SPLICE DETAIL FOR INSTALLATION

*** Refer to the Multi-Gutter Endcap and Splice detail for installation This run of multi-gutter uses (2) MGEC- as endcaps

Extended Façade CS Roof Panel w Multi-gutter and Nichiha Panel-Cap Trim Not by Chief

DRAFTING: DIMENSION HORIZ. LEG OF CAP TRIM. HAVE PM VERIFY DIM. WITH BLDR.

HORIZONTAL LEG OF FASCIA CAP TRIM

1

* NOTE: CONNECTION OF NICHIHA PANELS (NOT BY CHIEF), TO WALL OR FASCIA PANEL IS NOT BY CHIEF.

TAPE MASTIC SENT FOR BACK-UP PANEL SIDE LAPS. WARRANTY FASTENERS SENT FOR BACK-UP PANEL.

BL

X'-X"

X"

CAP TRIM (NOT BY CHIEF) #12-14 X 1 1/4" (TYP) (6" C.C. for CS PANEL) (12" C.C. for AP PANEL)

X

FASTENER (12" C.C.) (NOT BY CHIEF) 1/4-14 X 1 1/4" WT (6" C.C.)

XXX'-X"

OUTSIDE CLOSURE

INSIDE CLOSURE w/ TAPE MASTIC TOP AND BOTTOM 1/4-14 X 1 1/4" WT (6" C.C.) BACKUP PANEL

FASTENER (NOT BY CHIEF) (12" C.C.)

SPECIAL PURCHASED (IF BY CHIEF)

INSIDE CLOSURE W/ MASTIC TOP & BOTTOM

FACADE GIRT

GIRT

XXX'-X"

1/4-14 X 1 1/4" WT (4" C.C.) CS ROOF PANEL

* _" NICHIHA PANEL (NOT BY CHIEF)

#12-14 X 1 1/4" (6" C.C. for CS PANEL) (12" C.C. for AP PANEL)

FASCIA PANEL

** MULTI-GUTTER (MG-X)

EAVE STRUT

* _" NICHIHA PANEL (NOT BY CHIEF) WALL PANEL

** Refer to the Multi-Gutter Endcap and Splice detail for installation This run of multi-gutter uses (2) MGEC- as endcaps