Composite Material, Rigid Board, R-Seal

AP Metal Bldg Walkdoor-KD-Others Rigid Wall

AP Panel - Rigid Board Insulation in Wall - Walkdoor - Knocked-Down (By Chief), or Walkdoor Not by Chief Refer to Order Documents for Doors by Chief

Head Trim (HTT) lapped 4 1/4" min. past edge of door jamb. Flush with end of Jamb Trim (JTA).

Installation Steps: 1. Install Wrap Plate, if applicable. 2. Liner Cover Trim(LCT), if applicable. Use with Liner/Backer.

INSIDE CLOSURE Optional urethane caulk at HTT end. (NOT BY CHIEF)

Refer to Liner or Partition Panel Drawings.

3. Door. 4. Special Insulation Wrap Trim (SPT) at header and jambs. 5. Rigid Continuous Insulation. 6. Sheeting Support (SSP) 7. Header Trim (HTT). 8. Notch and slit wall panel. 6. Place wall panel over trims with foam inside closure full width of header. 7. Jamb Trim (JTA).

2 1/4" X 1/4" PANEL NOTCH

HEADER TRIM (HTT)

WALL PANEL SHEETING SUPPORT (SSP)

2" PANEL SLIT

2" SLIT

2 1/4" X 1/4" NOTCH

Optional urethane caulk at panel slit and notch. Caulk under JTA. (NOT BY CHIEF)

Notes: ·

#12-14 X ____"

Special Fastener =

X"

·

Rigid Continuous Insulation thickness =

· Rigid Continuous Insulation and vapor retarder are not by Chief. · Insulation is representative. Erector shall refer to insulation manufacturer’s installation information for further details/direction. The erector is responsible for providing the final solution for installation, air tightness, and performance of the liner insulation system. · The details shown are typical. · Not all details may apply. · Specific details for additional features will be provided for complete installation instructions. · Drill Ø1/8" holes for Blind Rivets. · Rivets spaced at 7'-0" C.C. are temporary fasteners.

For best weathertightness performance, JTA/SSP and Head Trim assembly should land in flat of panel. Layout, verify, and consider field locating framed opening as necessary. If this condition cannot be achieved, special field trim modifications, and/or additional urethane caulking Not By Chief may be required.

SPECIAL WRAP TRIM (SPT-x) JAMB TRIM (JTA)

EDGE OF DOOR FRAME FLAT OF HEAD TRIM

END OF JAMB TRIM (JTA)

WALL PANEL SLIT

JAMB TRIM (JTA)

TRIM DETAIL AT CORNERS

LINER COVER TRIM (LCT1 OR LCT2) (AS REQUIRED) (LINER COLOR) (Field modify as req'd) 1/8" X 3/8" BLIND RIVET (18" C.C.) (TYP.)

LINER COVER TRIM (LCT1 OR LCT2) (AS REQUIRED) (LINER COLOR) (Field modify as req'd) 1/8" X 3/8" BLIND RIVET (18" C.C.) (TYP.)

ZEE GIRT

RIGID CONTINUOUS INSULATION (NOT BY CHIEF)

OPENING WIDTH

OPENING WIDTH

BL

#12-14 X 1" PANCAKE HEAD FASTENER (36" C.C.)

WALL PANEL

JAMB

JAMB

SPECIAL FASTENER (12" C.C.) INSIDE CLOSURE #12-14 X 1" PANCAKE (7'-0" C.C.)

NOMINAL DOOR OPENING

NOMINAL DOOR OPENING

#12-14 X 1" PANCAKE HEAD (12" C.C.)

#12-14 X 1" PANCAKE HEAD (12" C.C.)

1/8" X 3/8" BLIND RIVET (3'-0" C.C.) TYP. SPECIAL PLATE. REFER TO FRAMING PLANS FOR PIECE MARK (PL)

SPECIAL FASTENER (12" C.C.)

SPECIAL FASTENER (12" C.C.)

DOOR FRAME

DOOR FRAME

HEADER TRIM (HTT)

Optional urethane caulk behind special wrap trim (NOT BY CHIEF)

Optional urethane caulk behind special wrap trim (NOT BY CHIEF)

* Provide air gap of 1/4" min. at bottom of panel to avoid corrosion.

BL

BL

* 1 4 "

LINER COVER TRIM (LCT1 OR LCT2) (AS REQUIRED) (LINER COLOR) (Field modify as req'd)

SPECIAL WRAP TRIM (SPT-x)

SPECIAL WRAP TRIM (SPT-x)

CUT RIB AS NEEDED

RIGID CONTINUOUS INSULATION (NOT BY CHIEF) SHEETING SUPPORT (SSP) WALL PANEL 1/4-14 X 7/8" (12" C.C.) JAMB TRIM (JTA)

RIGID CONTINUOUS INSULATION (NOT BY CHIEF) SHEETING SUPPORT (SSP) WALL PANEL 1/4-14 X 7/8" (12" C.C.) JAMB TRIM (JTA)

1

2 " MIN.

CUT RIB AS NEEDED

1/8" X 3/8" BLIND RIVET (7'-0" C.C.) SPECIAL WRAP TRIM (SPT-x)

***1 3/4"-2"

DOOR FRAME

***1/8"-3/4"

OPENING HEIGHT

NOMINAL

*** Locate JT/COT/HTT trim assembly to cover door frame avoiding interference with latch, door and hinges. Consider door swing interference.

*** Locate JT/COT/HTT trim assembly to cover door frame avoiding interference with latch, door and hinges. Consider door swing interference.

DOOR OPENING

1/4-14 X 7/8" (12" C.C.)

1/4-14 X 7/8" (12" C.C.)

WALKDOOR HEADER TRIM DETAILS

WALKDOOR JAMB TRIM DETAILS

ALTERNATE WALKDOOR JAMB TRIM DETAILS (Alternate detail for increased door swing clearance)

CEE HEADER