Composite Material, Rigid Board, R-Seal
AP OHD or 3-Sided Opening Rigid Wall
AP Panel - Rigid Board Insulation in Wall - OHD or 3-Sided Opening
NOTES: ·
#12-14 X ____"
Special Fastener =
·
Rigid Continuous Insulation thickness =
X"
· Rigid Continuous Insulation and vapor retarder are not by Chief. · Insulation is representative. Erector shall refer to insulation manufacturer’s installation information for further details/direction. The erector is responsible for providing the final solution for installation, air tightness, and performance of the liner insulation system. · The details shown below are typical. · Not all details may apply. · Specific details for additional features will be provided for complete installation instructions. · Drill Ø1/8" holes for Blind Rivets. · Rivets spaced at 7'-0" C.C. are temporary fasteners. · LCT1 or LCT2 used with Liner/Backer. Refer to Liner or Partition Panel Dwg. · Provide air gap of 1/4" min. at bottom of panels to avoid corrosion.
4 1/4"
HEADER TRIM WITH TROUGH (HTT)
NOTCH WALL PANEL FOR EXTENSION OF TRIM.
JAMB TRIM (JTA)
TRIM DETAIL AT CORNER
BL
1/8" X 3/8" BLIND RIVET (18" C.C.)
JAMB
RIGID CONTINUOUS INSULATION (NOT BY CHIEF)
___" RIGID CONTINUOUS INSULATION (NOT BY CHIEF)
WALL PANEL
SPECIAL TRIM (SPT-x)
INSIDE CLOSURE SPECIAL FASTENER (12" C.C.)
HEADER
JAMB TRIM (JTA)
BL
1/8" X 3/8" BLIND RIVET (18" C.C.)
1
4 "
1/4-14 X 7/8" (12" C.C.)
SPECIAL FASTENER (12" C.C.) WALL PANEL
HEADER TRIM (HTT)
1/8" X 3/8" BLIND RIVET (7'-0" C.C.)
SHEETING SUPPORT (SSP) 1/4-14 X 7/8" (12" C.C.)
SPECIAL TRIM (SPT-x)
HEADER WITH WRAP TRIM
AP JAMB WITH WRAP TRIM
Made with FlippingBook Annual report maker