Composite Material, Rigid Board, R-Seal
AP Window by Chief Rigid Wall
AP Panel - Rigid Board Insulation in Wall - Window by Chief
NOTES: ·
#12-14 X ____"
Special Fastener =
·
Rigid Continuous Insulation thickness =
X"
· Rigid Continuous Insulation and vapor retarder are not by Chief. · Insulation is representative. Erector shall refer to insulation manufacturer’s installation information for further details/direction. The erector is responsible for providing the final solution for installation, air tightness, and performance of the liner insulation system. · The details shown below are typical. · Not all details may apply. · Specific details for additional features will be provided for complete installation instructions. · Drill Ø1/8" holes for Blind Rivets. · Rivets spaced at 7'-0" C.C. are temporary fasteners. · LCT1 or LCT2 used with Liner/Backer. Refer to Liner or Partition Panel Dwg. · Provide air gap of 1/4" min. at bottom of panel to avoid corrosion.
4 1/4"
HEADER TRIM WITH TROUGH (HTT)
NOTCH WALL PANEL FOR EXTENSION OF TRIM.
JAMB TRIM (JTA)
JAMB TRIM (JT)
BL
#12-14 X 1" PANCAKE HEAD (36" C.C.) (TYP.) #12-14 X 1" PANCAKE HEAD (12" C.C.)
CEE HEADER
4 1/4"
ZEE GIRT
INSIDE CLOSURE
SPECIAL FASTENER (12" C.C.)
SPECIAL PLATE. REFER TO FRAMING PLANS FOR PIECE MARK (PL) 1/8" X 3/8" BLIND RIVET, (18" C.C.) WITH LINER COVER TRIM (LCT)
1
4 "
HEADER TRIM (HT)
TRIM DETAIL AT CORNER
1/8" X 3/8" BLIND RIVET (7'-0" C.C.)
LINER COVER TRIM (LCT2) LINER COVER TRIM (LCT1)
SPECIAL TRIM (SPT-x) URETHANE CAULK (NOT BY CHIEF)
1/8" X 3/8" BLIND RIVET, (18" C.C.) WITH LINER COVER TRIM (LCT) JAMB 3/16" BULBTITE RIVET (12" C.C.) (SIDE ONLY) 1/8" X 3/8" BLIND RIVET (7'-0" C.C.) (TYP.) #12-14 X 1" PANCAKE HEAD (12" C.C.)
OPENING WIDTH
LINER COVER TRIM (LCT1) (AS REQUIRED) 1/8" X 3/8" BLIND RIVET, (18" C.C.) WITH LINER COVER TRIM (LCT) LINER COVER TRIM (LCT2) (AS REQUIRED)
WINDOW BY CHIEF
LINER COVER TRIM (LCT1) LINER COVER TRIM (LCT2)
URETHANE CAULK (NOT BY CHIEF)
WINDOW BY CHIEF
SPECIAL TRIM (SPT-x)
BL
SPECIAL JAMB TRIM (SPT-x) URETHANE CAULK (NOT BY CHIEF) 1/4-14 X 7/8" (12" C.C.)
INSIDE CLOSURE
WINDOW SILL
1/8" X 3/8" BLIND RIVET (7'-0" C.C.)
RIGID CONTINUOUS INSULATION (NOT BY CHIEF)
WALL PANEL (TYP.) RIGID CONTINUOUS INSULATION (NOT BY CHIEF) (TYP.) SPECIAL FASTENER (12" C.C.)
WALL PANEL
JAMB TRIM (JTA)
SHEETING SUPPORT (SSP)
1/4-14 X 7/8" (12" C.C.)
SPECIAL FASTENER (12" C.C.)
OPENING DETAILS AT HEADER AND SILL
OPENING DETAILS AT JAMB