Composite Material, Rigid Board, R-Seal

AP OHD or 3-Sided Opening Rigid Wall

AP Panel - Rigid Board Insulation in Wall - OHD or 3-Sided Opening

INSIDE CLOSURE

Installation Steps: 1. Rigid Continuous Insulation. 2. Special Door Trim (SPT). 3. Sheeting Support (SSP) 4. Header Trim (HTT). 5. Notch and slit wall panel. 6. Place wall panel over trims with foam inside closure full width of header. 7. Jamb Trim (JTA).

Head Trim (HTT) lapped 4 1/4" min. past edge of door jamb. Flush with end of Jamb Trim (JTA).

Optional urethane caulk at HTT end. (NOT BY CHIEF)

HEADER TRIM (HTT)

2 1/4" X 1/4" PANEL NOTCH

SHEETING SUPPORT (SSP)

Notes: ·

#12-14 X ____"

Special Fastener =

2" PANEL SLIT

X"

·

Rigid Continuous Insulation thickness =

· Rigid Continuous Insulation and vapor retarder are not by Chief. · Insulation is representative. Erector shall refer to insulation manufacturer’s installation information for further details/direction. The erector is responsible for providing the final solution for installation, air tightness, and performance of the liner insulation system. · The details shown are typical. · Not all details may apply. · Specific details for additional features will be provided for complete installation instructions. · Drill Ø1/8" holes for Blind Rivets. · Rivets spaced at 7'-0" C.C. are temporary fasteners.

2" X 1/4" NOTCH

2" SLIT

Optional urethane caulk at panel slit and notch. Caulk under JTA. (NOT BY CHIEF)

WALL PANEL

For best weathertightness performance, JTA/SSP and Head Trim assembly should land in flat of panel. Layout, verify, and consider field locating framed opening as necessary. If this condition cannot be achieved, special field trim modifications, and/or additional urethane caulking Not By Chief may be required.

DOOR JAMB JAMB TRIM (JTA)

EDGE OF DOOR JAMB FLAT OF HEAD TRIM

END OF JAMB TRIM (JTA)

SPECIAL DOOR TRIM (SPT-x) RERFER TO PANEL DRAWINGS

WALL PANEL SLIT

JAMB TRIM (JTA)

TRIM DETAIL AT CORNERS

RIGID CONTINUOUS INSULATION (NOT BY CHIEF)

1/8" X 3/8" BLIND RIVET (7'-0" C.C.) (TYP.)

OPENING WIDTH

OPENING WIDTH

WALL PANEL

BL

1/8" X 3/8" BLIND RIVET (7'-0" C.C.)

JAMB

JAMB

SPECIAL FASTENER (12" C.C.) INSIDE CLOSURE

SPECIAL FASTENER (12" C.C.)

WRB TAPE OR URETHANE SEALANT AROUND PENETRATIONS (NOT BY CHIEF)

HEADER

SPECIAL WRAP TRIM (SPT-x)

HEADER TRIM (HTT)

BL

BL

* Provide air gap of 1/4" min. at bottom of panel to avoid corrosion.

CUT RIB AS NEEDED

* 1 4 "

1/8" X 3/8" BLIND RIVET, 18" C.C. WITH DOOR TRIM (DT)

RIGID CONTINUOUS INSULATION (NOT BY CHIEF)

RIGID CONTINUOUS INSULATION (NOT BY CHIEF) SHEETING SUPPORT (SSP) WALL PANEL 1/4-14 X 7/8" (12" C.C.) JAMB TRIM (JTA) 1/4-14 X 7/8" (12" C.C.)

SPECIAL WRAP TRIM (SPT-x)

OPENING HEIGHT

For Walkdoors to avoid interference with latch, door, or hinges, hold JT/COT/HTT trim assembly back from jamb max 3/4", as necessary.

OPENING DETAIL AT HEADER

FRAMED OPENING DETAIL AT JAMB

OPTIONAL FRAMED OPENING DETAIL AT JAMB (Optional detail for increased weathertightness (Not by Chief))