Composite Material, Rigid Board, R-Seal

AP Window or 4-Sided Opening w Sill Flashing-WFS Rigid Wall

AP Panel - Rigid Board Insulation in Wall - Window Not by Chief or 4-Sided Opening - with Sill Flashing – WFS

NOTES: ·

#12-14 X ____"

Special Fastener =

·

Rigid Continuous Insulation thickness =

X"

· Rigid Continuous Insulation and vapor retarder are not by Chief. · Insulation is representative. Erector shall refer to insulation manufacturer’s installation information for further details/direction. The erector is responsible for providing the final solution for installation, air tightness, and performance of the liner insulation system. · The details shown below are typical. · Not all details may apply. · Specific details for additional features will be provided for complete installation instructions. · Drill Ø1/8" holes for Blind Rivets. · Rivets spaced at 7'-0" C.C. are temporary fasteners. · LCT1 or LCT2 used with Liner/Backer. Refer to Liner or Partition Panel Dwg. · Provide air gap of 1/4" min. at bottom of panel to avoid corrosion.

4 1/4"

HEADER TRIM (HT)

NOTCH WALL PANEL FOR EXTENSION OF TRIM.

JAMB TRIM (JTA)

SILL TRIM FLASHING (WFS)

BL

#12-14 X 1" PANCAKE HEAD (36" C.C.) (TYP.)

CEE HEADER

4 1/4"

ZEE GIRT

INSIDE CLOSURE

SPECIAL FASTENER (12" C.C.)

SPECIAL PLATE. REFER TO FRAMING PLANS FOR PIECE MARK (PL) 1/8" X 3/8" BLIND RIVET, (18" C.C.) WITH LINER COVER TRIM (LCT)

1

4 "

TRIM DETAIL AT CORNER

HEADER TRIM (HT)

LINER COVER TRIM (LCT1) 1/8" X 3/8" BLIND RIVET (7'-0" C.C.) (2) 1/8" X 3/8" BLIND RIVET (3'-0" C.C.)

LINER COVER TRIM (LCT1)

LINER COVER TRIM (LCT1) (AS REQUIRED)

JAMB

1/8" X 3/8" BLIND RIVET (7'-0" C.C.)

RIGID CONTINUOUS INSULATION (NOT BY CHIEF)

1/8" X 3/8" BLIND RIVET (7'-0" C.C.)

(2) 1/8" X 3/8" BLIND RIVET (3'-0" C.C.)

LINER COVER TRIM (LCT1) (AS REQUIRED)

SILL TRIM FLASHING (WFS)

1/8" X 3/8" BLIND RIVET, (18" C.C.) WITH LINER COVER TRIM (LCT)

BL

LINER COVER TRIM (LCT1)

INSIDE CLOSURE 1/4-14 7/8" (12" C.C.) WALL PANEL RIGID CONTINUOUS INSULATION (NOT BY CHIEF) SPECIAL FASTENER (12" C.C.)

WALL PANEL

JAMB TRIM (JTA)

WINDOW SILL

SHEETING SUPPORT (SSP)

SPECIAL FASTENER (12" C.C.) 1/4-14 X 7/8" (12" C.C.)

1/4-14 X 7/8" (12" C.C.)

OPENING DETAILS AT HEADER AND SILL

FRAMED OPENING DETAILS AT JAMB