Composite Material, Rigid Board, R-Seal
AP Window or 4-Sided Opening w Jamb Trim-JT Rigid Wall
AP Panel - Rigid Board Insulation in Wall - Window Not by Chief or 4-Sided Opening - with Sill Jamb Trim – JT
Head Trim (HTT) lapped 4 1/4" min. past edge of door jamb. Flush with end of Jamb Trim (JTA).
Installation Steps: 1. Install Wrap Plate, if applicable. 2. Liner Cover Trim(LCT), if applicable. Use with Liner/Backer. Refer to Liner or Partition Panel Drawings. 3. Special Sill Jamb Trim (SPT) and Special Wrap Trim (SPT). 4. Rigid Continuous Insulation. 5. Header Trim (HTT).
INSIDE CLOSURE
Optional urethane caulk at HTT end. (NOT BY CHIEF)
HEADER TRIM (HTT)
2 1/4" X 1/4" PANEL NOTCH
SHEETING SUPPORT (SSP)
6. Sheeting Support (SSP) 7. Notch and slit wall panel. 8. Place wall panel over trims with foam inside closure full width of header and sill. 9. Jamb Trim (JTA).
JAMB TRIM (JTA) WALL PANEL
2" PANEL SLIT
2" X 1/4" NOTCH
2" SLIT
Notes: ·
#12-14 X ____"
Special Fastener =
LINER COVER TRIMS
·
Rigid Continuous Insulation thickness =
X"
Optional urethane sealant at JT end (NOT BY CHIEF) SPECIAL SILL JAMB TRIM (SPT-x) SPECIAL WRAP TRIM (SPT-x)
· Rigid Continuous Insulation and vapor retarder are not by Chief. · Insulation is representative. Erector shall refer to insulation manufacturer’s installation information for further details/direction. The erector is responsible for providing the final solution for installation, air tightness, and performance of the liner insulation system. · The details shown below are typical. · Not all details may apply. · Specific details for additional features will be provided for complete installation instructions. · Drill Ø1/8" holes for Blind Rivets. · Rivets spaced at 7'-0" C.C. are temporary fasteners.
Optional urethane caulk at panel slit and notch. Caulk under JTA. (NOT BY CHIEF)
For best weathertightness performance, JTA/SSP and Head Trim assembly should land in flat of panel. Layout, verify, and consider field locating framed opening as necessary. If this condition cannot be achieved, special field trim modifications, and/or additional urethane caulking Not By Chief may be required.
EDGE OF WINDOW JAMB FLAT OF HEAD TRIM
END OF JAMB TRIM (JTA)
4 1/4" TO EDGE OF WINDOW JAMB
WALL PANEL SLIT
OPTIONAL JAMB TRIM FOLD AT END
JAMB TRIM (JTA)
NOTCH AND SLIT WALL PANEL FOR EXTENSION OF TRIM. (TYP.) ** SPECIAL FASTENER (12" C.C.) (TYP.) WALL PANEL Optional urethane caulk behind special sill jamb trim (NOT BY CHIEF)
Optional Urethane caulk around 2" panel slit and under JTA (NOT BY CHIEF) (TYP.)
TRIM DETAIL AT CORNERS
#12-14 X 1" PANCAKE HEAD (36" C.C.) (TYP.)
BL
ZEE GIRT
1/8" X 3/8" BLIND RIVET, (18" C.C.) WITH LINER COVER TRIM (LCT) JAMB
#12-14 X 1" PANCAKE HEAD (12" C.C.) 1/8" X 3/8" BLIND RIVET (7'-0" C.C.)
OPENING WIDTH
1/8" X 3/8" BLIND RIVET, (18" C.C.) WITH COVER TRIM (LCT) SPECIAL PLATE. REFER TO FRAMING PLANS FOR PIECE MARK (PL) LINER COVER TRIM (LCT1) (AS REQUIRED) (LINER COLOR)
SPECIAL FASTENER (12" C.C.)
LINER COVER TRIM (LCT1) (AS REQUIRED) (LINER COLOR)
CEE HEADER
INSIDE CLOSURE
SPECIAL FASTENER (12" C.C.)
* Provide air gap of 1/4" min. at bottom of panel to avoid corrosion.
* 1 4 "
#12-14 X 1" PANCAKE HEAD (12" C.C.)
LINER COVER TRIM (LCT2) (AS REQUIRED) (LINER COLOR)
HEADER TRIM (HTT)
SPECIAL WRAP TRIM (SPT-x)
BL
LINER COVER TRIM (LCT2) (AS REQUIRED) (LINER COLOR)
SPECIAL WRAP TRIM (SPT-x) Optional urethane caulk behind special wrap trim (NOT BY CHIEF)
OPENING
SPECIAL SILL JAMB TRIM (SPT-x)
RIGID CONTINUOUS INSULATION (NOT BY CHIEF) SHEETING SUPPORT (SSP) WALL PANEL 1/4-14 X 7/8" (12" C.C.) JAMB TRIM (JTA)
FRAMING (NOT BY CHIEF) 1/8" X 3/8" BLIND RIVET, (18" C.C.) WITH COVER TRIM (LCT)
1/4-14 X 7/8" (12" C.C.) CUT RIB AS NEEDED
INSIDE CLOSURE SPECIAL FASTENER (12" C.C.)
Optional urethane caulk behind special sill jamb trim (NOT BY CHIEF)
#12-14 X 1" PANCAKE HEAD (12" C.C.)
WALL PANEL (TYP.)
RIGID CONTINUOUS INSULATION (NOT BY CHIEF)
OPENING DETAILS AT HEADER AND SILL
FRAMED OPENING DETAIL AT JAMB