Composite Material, Rigid Board, R-Seal

CS OHD or 3-Sided Opening Rigid Wall

CS Panel - Rigid Board Insulation in Wall - OHD or 3-Sided Opening

Head Trim (HTT) lapped 3" min. past flat of Jamb Trim (JT). Flush with Cover Trim (COT).

Installation Steps: 1. Rigid Continuous Insulation. 2. Special Wrap Trim (SPT). 3. Jamb Trim (JT) with notch at header. 4. Header Trim (HTT). 5. Notch and slit wall panel. 6. Place wall panel over trims with foam inside closure full width of header. 7. Cover Trim (COT).

2" JAMB TRIM NOTCH

2" X 1/4" PANEL NOTCH

HEADER TRIM (HTT)

1" PANEL SLIT

Notes: ·

Optional Urethane caulk around 1" panel slit and under COT (NOT BY CHIEF) (TYP.)

INSIDE CLOSURE

#12-14 X ____"

Special Fastener =

X"

·

Rigid Continuous Insulation thickness =

· Rigid Continuous Insulation and vapor retarder are not by Chief. · Insulation is representative. Erector shall refer to insulation manufacturer’s installation information for further details/direction. The erector is responsible for providing the final solution for installation, air tightness, and performance of the liner insulation system. · The details shown are typical. · Not all details may apply. · Specific details for additional features will be provided for complete installation instructions. · Drill Ø1/8" holes for Blind Rivets. · Rivets spaced at 7'-0" C.C. are temporary fasteners. · LCT1 or LCT2 used with Liner/Backer. Refer to Liner or Partition Panel Dwg. · Provide air gap of 1/4" min. at bottom of panel to avoid corrosion.

1" SLIT

2" X 1/4" NOTCH

For best weathertightness performance, JT/COT and Head Trim assembly should land in flat of panel. Layout, verify, and consider field locating framed opening as necessary. If this condition cannot be achieved, special field trim modifications, omitting COT trim, and/or additional urethane caulking Not By Chief may be required.

JAMB TRIM (JT)

2" JAMB TRIM NOTCH

FLAT OF JAMB TRIM FLAT OF HEAD TRIM

SPECIAL WRAP TRIM (SPT-x). REFER TO PANEL DRAWINGS.

COVER TRIM (COT)

WALL PANEL SLIT

TRIM DETAIL AT CORNERS

RIGID CONTINUOUS INSULATION (NOT BY CHIEF)

1/8" X 3/8" BLIND RIVET (7'-0" C.C.) (TYP.)

OPENING WIDTH

WALL PANEL

BL

1/8" X 3/8" BLIND RIVET (7'-0" C.C.)

JAMB

OPENING WIDTH

**#12-14 X 1 1/4" (6" C.C.) INSIDE CLOSURE

JAMB

HEADER

SPECIAL WRAP TRIM (SPT-x)

HEADER TRIM (HTT)

WRB TAPE OR BUTYL SEALANT AROUND

BL

* Provide air gap of 1/4" min. at bottom of panel to avoid corrosion.

PENETRATIONS (NOT BY CHIEF)

* 1 4 "

1/8" X 3/8" BLIND RIVET, 18" C.C. WITH DOOR TRIM (DT)

JAMB TRIM (JT)

RIGID CONTINUOUS INSULATION (NOT BY CHIEF)

BL

CUT RIB AS NEEDED

SPECIAL WRAP TRIM (SPT-x)

WALL PANEL SPECIAL FASTENER (12" C.C.) (TYP.) 1/8" X 3/8" BLIND RIVET (7'-0" C.C.)

RIGID CONTINUOUS INSULATION (NOT BY CHIEF)

OPENING HEIGHT

For Walkdoors to avoid interference with latch, door, or hinges, hold JT/COT/HTT trim assembly back from jamb max 3/4", as necessary.

COVER TRIM (COT) 1/8" X 3/8" BLIND RIVET (18" C.C.)

OPENING DETAIL AT HEADER

FRAMED OPENING DETAIL AT JAMB

OPTIONAL FRAMED OPENING DETAIL AT JAMB (Optional detail for increased weathertightness (Not by Chief))