Composite Material, Rigid Board, R-Seal
CS Window by Chief Rigid Wall
CS Panel - Rigid Board Insulation in Wall - Window by Chief
Header Trim (HTT) and Sill Trim (JT) lapped 3" min. past flat of Jamb Trim (JT). Flush with Cover Trim (COT).
X" Installation Steps: 1. Install Wrap Plate, if applicable. 2. Liner Cover Trim(LCT), if applicable. Use with Liner/Backer. Refer to Liner or Partition Panel Drawings. 3. Window 4. Special Sill, Special Jamb Trims (SPT). 5. Rigid Continuous Insulation. 6. Jamb Trim (JT) with notch at header. 7. Header Trim (HTT). 8. Notch and slit wall panel. 9. Place wall panel over trims with foam inside closures full width of header. 10. Cover Trim (COT). · Rigid Continuous Insulation and vapor retarder are not by Chief. · Insulation is representative. Erector shall refer to insulation manufacturer’s installation information for further details/direction. The erector is responsible for providing the final solution for installation, air tightness, and performance of the liner insulation system. · The details shown below are typical. · Not all details may apply. · Specific details for additional features will be provided for complete installation instructions. · Drill Ø1/8" holes for Blind Rivets. · Rivets spaced at 7'-0" C.C. are temporary fasteners. · LCT1 or LCT2 used with Liner/Backer. Refer to Liner or Partition Panel Dwg. Notes: · Special Fastener = · Rigid Continuous Insulation thickness = #12-14 X ____"
2" JAMB TRIM NOTCH
2" X 1/4" PANEL NOTCH
1" PANEL SLIT
HEADER TRIM (HTT)
INSIDE CLOSURE JAMB TRIM (JT)
1" SLIT
2" X 1/4" NOTCH
SPECIAL JAMB TRIM (SPT-x)
2" JAMB TRIM NOTCH
LINER COVER TRIMS
For best weathertightness performance, JT/COT and Head/Sill Trim assembly should land in flat of panel. Layout, verify, and consider field locating framed opening as necessary. If this condition cannot be achieved, special field trim modifications, omitting COT trim, and/or additional urethane caulking Not By Chief may be required.
SIKA-511
FLAT OF JAMB TRIM FLAT OF HEAD TRIM
3" TO FLAT OF JAMB TRIM
WALL PANEL SLIT
NOTCH AND SLIT WALL PANEL FOR EXTENSION OF TRIM. (TYP.) SPECIAL FASTENER (6" C.C.) WALL PANEL 1/8" X 3/8" BLIND RIVET, (18" C.C.) WITH LINER COVER TRIM (LCT) SPECIAL SILL JAMB TRIM (SPT-x)
COVER TRIM (COT)
Optional Urethane caulk around 1" panel slit and under COT (NOT BY CHIEF) (TYP.)
TRIM DETAIL AT CORNERS (Window not Shown)
BL
#12-14 X 1" PANCAKE HEAD (36" C.C.) (TYP.)
ZEE GIRT
SPECIAL FASTENER (6" C.C.) #12-14 X 1" PANCAKE HEAD (12" C.C.) 1/8" X 3/8" BLIND RIVET (7'-0" C.C.)
1/8" X 3/8" BLIND RIVET, (18" C.C.) WITH LINER COVER TRIM (LCT) JAMB 3/16" BULBTITE RIVET (12" C.C.) (SIDE ONLY) 1/8" X 3/8" BLIND RIVET (7'-0" C.C.) (TYP.)
SPECIAL PLATE. REFER TO FRAMING PLANS FOR PIECE MARK (PL)
OPENING WIDTH
INSIDE CLOSURE
CEE HEADER
LINER COVER TRIM (LCT1) LINER COVER TRIM (LCT2)
* 1 4 "
1/8" X 3/8" BLIND RIVET, (18" C.C.) WITH LINER COVER TRIM (LCT)
HEADER TRIM (HTT)
WINDOW BY CHIEF
SPECIAL JAMB TRIM (SPT-x)
#12-14 X 1" PANCAKE HEAD (12" C.C.)
URETHANE CAULK (NOT BY CHIEF)
LINER COVER TRIM (LCT1)
WINDOW BY CHIEF
BL
1/8" X 3/8" BLIND RIVET, (18" C.C.) WITH LINER COVER TRIM (LCT) * Provide air gap of 1/4" min. at bottom of panel to avoid corrosion.
LINER COVER TRIM (LCT2)
OPENING
URETHANE CAULK (NOT BY CHIEF)
URETHANE CAULK (NOT BY CHIEF) SPECIAL SILL JAMB TRIM (SPT-x)
SPECIAL JAMB TRIM (SPT-x)
SPECIAL FASTENER (12" C.C.) WALL PANEL RIGID CONTINUOUS INSULATION (NOT BY CHIEF) 1/8" X 3/8" BLIND RIVET (7'-0" C.C.)
JAMB TRIM (JT)
CUT RIB AS NEEDED 1/8" X 3/8" BLIND RIVET (18" C.C.) (TYP.)
INSIDE CLOSURE SPECIAL FASTENER (6" C.C.)
GIRT/SILL
#12-14 X 1" PANCAKE HEAD (12" C.C.)
COVER TRIM (COT)
RIGID CONTINUOUS INSULATION (NOT BY CHIEF)
WALL PANEL (TYP.)
CHIEF WINDOW HEADER AND SILL
FRAMED OPENING DETAILS AT JAMB
Made with FlippingBook Annual report maker