Eave and Gable Extensions
Eave Ext Horiz Soff Low Gable Ext - FSP Soffit Inset Gable and CS Roof Low Pitch
REFER TO GABLE SECTIONS FOR ROOF PANEL AND GABLE TRIM ATTACHMENTS AT THE BUILDING GABLE.
NOTE: * PRE-DRILL TOP AND BOTTOM FLANGE OF EXTENSION BEAM FOR FASTENERS
*** DRAFTING NOTE: INSIDE CLOSURE MUST BE PROVIDED ON BUILDINGS WITH LINER INSULATION SYSTEM.
* (2) #12-14 X 1 1/4" (WALL COLOR) (TYP.)
1
SPECIAL CHANNEL (PL- )
INSIDE CLOSURE
***
EAVE EXTENSION BEAM * #12-14 X 1 1/4" (WALL COLOR) (AT PURLIN)
BL
#12-14 X 1 1/4" (TYP) (6" C.C. for CS PANEL) (12" C.C. for AP PANEL)
1"
INTERMEDIATE PURLIN
EAVE EXTENSION END PANEL
FRAMING CONDITION NOT SHOWN
#12-14 X 1" PANCAKE HEAD (24" C.C.)
** INSIDE CLOSURE
SOFFIT RAKE ANGLE (A-20)
SOFFIT TRIM (VPST)
XXX' - X"
FSP SOFFIT PANEL
1
4 "
#12-14 X 1" PANCAKE HEAD (12" C.C.) (TYP.)
**DRAFTING: INSIDE CLOSURE NOT REQ'D IF WALLS ARE "CS INSULATED" Provide air gap of 1/4" min. at bottom of panel to avoid corrosion.
PANEL SUPPORT (SSSP) 1/8" X 3/8" BLIND RIVET (12" C.C.)
Made with FlippingBook flipbook maker