Eave and Gable Extensions

LS Eave Ext Only - Horiz FSP Soffit Inset Gable and CS Roof Panel Low Pitch

REFER TO GABLE SECTIONS FOR ROOF PANEL AND GABLE TRIM ATTACHMENTS AT THE BUILDING GABLE.

NOTE: * PRE-DRILL TOP AND BOTTOM FLANGE OF EXTENSION BEAM FOR FASTENERS

*** DRAFTING NOTE: INSIDE CLOSURE MUST BE PROVIDED ON BUILDINGS WITH LINER INSULATION SYSTEM.

* (2) #12-14 X 1 1/4" (WALL COLOR) (TYP.)

1

SPECIAL CHANNEL (PL- )

INSIDE CLOSURE

***

EAVE EXTENSION BEAM * #12-14 X 1 1/4" (WALL COLOR) (AT PURLIN)

BL

#12-14 X 1 1/4" (TYP) (6" C.C. for CS PANEL) (12" C.C. for AP PANEL)

1"

INTERMEDIATE PURLIN

EAVE EXTENSION END PANEL

FRAMING CONDITION NOT SHOWN

#12-14 X 1" PANCAKE HEAD (24" C.C.)

INSIDE CLOSURE **

SOFFIT RAKE ANGLE (A-20)

SOFFIT TRIM (VPST)

XXX' - X"

FSP SOFFIT PANEL

1

4 "

#12-14 X 1" PANCAKE HEAD (12" C.C.) (TYP.)

**DRAFTING: INSIDE CLOSURE NOT REQ'D IF WALLS ARE "CS INSULATED" Provide air gap of 1/4" min. at bottom of panel to avoid corrosion.

PANEL SUPPORT (SSSP) 1/8" X 3/8" BLIND RIVET (12" C.C.)