High Profile Trim
STC-MSC Gable Ext Tail End High Profile Trim-Field Bend Leg AP Soffit and Thermal Spacer
*NOTE:IT IS IMPORTANT THAT 1/4-14 X 1 1/4" SHOULDER FASTENERS ARE INSTALLED THROUGH THE CENTER OF THE SLOTTED HOLES OF THE RAKE SUPPORT.
1
PURLIN
PURLIN CLOSURE AT RIDGE IS TO BE FIELD CUT AND FASTENED TOGETHER WITH (2) 1/8" X 3/8" BLIND RIVETS.
GABLE EXTENSION DIMENSION
PURLIN CLOSURE (GPC2 OR GPC3) (TYP) (2) PURLIN CLOSURE CLIPS (GCC1) AT EACH PURLIN CLOSURE (2) #12-14 X 1 1/4" EACH CLIP (2) 1/8" X 3/8" BLIND RIVETS (EACH CLIP)
CLOSURE CLIPS (GCC-1) (TYP.)
TRI-BEAD TAPE SEALER NOTE: FIELD FORM A 3" VERTICAL ROOF PANEL LEG TO FIT FINAL DIMENSION #12-14 X 1 1/4" (12" C.C.) (TRIM COLOR) * 1/4-14 X 1 1/4" SHOULDER (24" C.C.) GABLE TRIM (GTMH)
BL
PURLIN CLOSURE (TYP.)
1/4-14 X 1 1/4" WT (12" C.C.) RAKE SUPPORT (A-20-T) (NOT BY CHIEF) PRE-GLUED THERMAL SPACER
STC/MSC ROOF PANEL
PURLIN
THERMAL SPACER
(NOT BY CHIEF)
#12-14 X 1 1/4" (12" C.C.) (SOFFIT COLOR)
PURLIN CLOSURE (GPC) PANEL CLIP w/FASTENERS
#12-14 X 1" PANCAKE HEAD EACH PURLIN
(2) 1/8" X 3/8" BLIND RIVETS (TYP.)
PURLIN
(2) #12-14 X 1 1/4"' PER CLOSURE
(2) 1/4-14 X 7/8"
PURLIN CLOSURE CLIP (GCC-1) (FIELD MODIFY CLIP AS REQ'D) (2) 1/8" X 3/8" BLIND RIVETS TO CONNECT EACH CLIP TO EACH PURLIN CLOSURE (2) #12-14 X 1 1/4" TO CONNECT EACH CLIP TO EACH PURLIN
TOP VIEW
GABLE TRIM SUPPORT (GTS) (10'-0" C.C.)
1/4-14 X 7/8" (12" C.C.) GABLE EXPANSION TRIM (GET)
#12-14 X 1" PANCAKE HEAD (2 PER PURLIN)
AP SOFFIT PANEL
NOTE: · Purlin closure is to be field cut between eave struts and purlins. · Closure clips may need to be field cut to fit in purlin and staggered so #12-14 X 1 1/4" fasteners don't interfere.
#12-14 X 1 1/4" (6" C.C. for CS PANEL) (12" C.C. for AP PANEL) RAKE ANGLE (A-20-B)
GABLE EXTENSION CHANNEL (GEC) EXTENSION GABLE FLASHING (EGFA) 1/4-14 X 7/8" (12" C.C.) **
#12-14 X 1 1/4" AT EACH PURLIN ROW (WALL COLOR
1/4-14 X 7/8" (12" C.C.) (SOFFIT COLOR)
EAVE STRUT
JAMB TRIM (JT) INSIDE CLOSURE ***
** HIGH PROFILE TRIM SOFFITED GABLE EXT STC / MSC
TRIM TYPE EGFA EFHP
L OR H SYSTEM
PURLIN SIZE
PANEL SUPPORT TRIM (SSP) (TYP.) 1/4-14 X 7/8" (12" C.C.)
(2) #12-14 X 1 1/4" (2) 1/8" X 3/8" BLIND RIVETS PURLIN CLOSURE CLIPS (GCC1)
8
HIGH HIGH
10
1/4-14 X 7/8" (12" C.C.) PANEL CAP TRIM (SCT)
EGFA = EXTENSION GABLE FLASHING EFHP = EXT. FLASHING HIGH PROFILE
*** DRAFTING NOTE: INSIDE CLOSURE MUST BE PROVIDED ON BUILDINGS WITH LINER INSULATION SYSTEM.
PURLIN CLOSURE INSTALLATION
WALL PANEL