High Profile Trim
STC-MSC Gable Ext Tail End High Profile Trim-Field Bend Leg CS Soffit and Thermal Spacer
1
PURLIN
PURLIN CLOSURE AT RIDGE IS TO BE FIELD CUT AND FASTENED TOGETHER WITH (2) 1/8" X 3/8" BLIND RIVETS.
*NOTE:IT IS IMPORTANT THAT 1/4-14 X 1 1/4" SHOULDER FASTENERS ARE INSTALLED THROUGH THE CENTER OF THE SLOTTED HOLES OF THE RAKE SUPPORT.
PURLIN CLOSURE (GPC2 OR GPC3) (TYP) (2) PURLIN CLOSURE CLIPS (GCC1) AT EACH PURLIN CLOSURE (2) #12-14 X 1 1/4" EACH CLIP (2) 1/8" X 3/8" BLIND RIVETS (EACH CLIP)
GABLE EXTENSION DIMENSION
CLOSURE CLIPS (GCC-1) (TYP.)
PURLIN CLOSURE (TYP.)
BL
TRI-BEAD TAPE SEALER NOTE: FIELD FORM A 3" VERTICAL ROOF PANEL LEG TO FIT FINAL DIMENSION #12-14 X 1 1/4" (12" C.C.) (TRIM COLOR) * 1/4-14 X 1 1/4" SHOULDER (24" C.C.) GABLE TRIM (GTMH) GABLE TRIM SUPPORT (GTS) (10'-0" C.C.) GABLE EXPANSION TRIM (GET) 1/4-14 X 7/8" (12" C.C.) (2) 1/4-14 X 7/8"
1/4-14 X 1 1/4" WT (12" C.C.) RAKE SUPPORT (A-20-T) (NOT BY CHIEF) PRE-GLUED THERMAL SPACER
STC/MSC ROOF PANEL
PURLIN
THERMAL SPACER
(NOT BY CHIEF)
#12-14 X 1 1/4" (12" C.C.) (SOFFIT COLOR)
PURLIN CLOSURE (GPC) PANEL CLIP w/FASTENERS
(2) 1/8" X 3/8" BLIND RIVETS (TYP.)
#12-14 X 1" PANCAKE HEAD EACH PURLIN
(2) #12-14 X 1 1/4"' PER CLOSURE
PURLIN
PURLIN CLOSURE CLIP (GCC-1) (FIELD MODIFY CLIP AS REQ'D) (2) 1/8" X 3/8" BLIND RIVETS TO CONNECT EACH CLIP TO EACH PURLIN CLOSURE (2) #12-14 X 1 1/4" TO CONNECT EACH CLIP TO EACH PURLIN
TOP VIEW
#12-14 X 1" PANCAKE HEAD (2 PER PURLIN)
NOTE: · Purlin closure is to be field cut between eave struts and purlins. · Closure clips may need to be field cut to fit in purlin and staggered so #12-14 X 1 1/4" fasteners don't interfere.
CS SOFFIT PANEL
GABLE EXTENSION CHANNEL (GEC) EXTENSION FLASHING (EFCP) **
#12-14 X 1 1/4" (6" C.C. for CS PANEL) (12" C.C. for AP PANEL)
#12-14 X 1 1/4" AT EACH PURLIN ROW (WALL COLOR
EAVE STRUT
** HIGH PROFILE TRIM SOFFITED GABLE EXT STC / MSC
1/4-14 X 7/8" (12" C.C.) (SOFFIT COLOR)
TRIM TYPE EFCP ECHP
PURLIN SIZE
L OR H SYSTEM
INSIDE CLOSURE ***
(2) #12-14 X 1 1/4" (2) 1/8" X 3/8" BLIND RIVETS PURLIN CLOSURE CLIPS (GCC1)
8
HIGH HIGH
RAKE ANGLE (A-20-B)
10
EFCP = EXTENSION FLASHING HIGH PROFILE ECHP = EXT. FLASHING HIGH PROFILE
JAMB TRIM (JT)
*** DRAFTING NOTE: INSIDE CLOSURE MUST BE PROVIDED ON BUILDINGS WITH LINER INSULATION SYSTEM.
1/4-14 X 7/8" (12" C.C.) PANEL CAP TRIM (SCT)
PURLIN CLOSURE INSTALLATION
WALL PANEL