High Profile Trim

STC-MSC Gable Ext Tail End High Profile Trim-Field Bend Leg-Term Trim CS Soffit Thermal Spacer

1

PURLIN

GABLE EXTENSION DIMENSION TRI-BEAD TAPE SEALER 1/4-14 X 1 1/4" WT (12" C.C.)

PURLIN CLOSURE AT RIDGE IS TO BE FIELD CUT AND FASTENED TOGETHER WITH (2) 1/8" X 3/8" BLIND RIVETS.

PURLIN CLOSURE (GPC2 OR GPC3) (TYP) (2) PURLIN CLOSURE CLIPS (GCC1) AT EACH PURLIN CLOSURE (2) #12-14 X 1 1/4" EACH CLIP (2) 1/8" X 3/8" BLIND RIVETS (EACH CLIP)

TRI-BEAD TAPE SEALER 1/4-14 X 7/8" WT (6" C.C.) GABLE TRIM (GTMH) RAKE SUPPORT (A-20-T) TERMINATION TRIM (GTTM) 1/4-14 X 1 1/4" WT (24" C.C.) NOTE: FIELD FORM A 3" VERTICAL ROOF PANEL LEG TO FIT FINAL DIMENSION * 1/4-14 X 1 1/4" SHOULDER (24" C.C.)

CLOSURE CLIPS (GCC-1) (TYP.)

BL

PURLIN CLOSURE (TYP.)

*NOTE:IT IS IMPORTANT THAT 1/4-14 X 1 1/4" SHOULDER FASTENERS ARE INSTALLED THROUGH THE CENTER OF THE SLOTTED HOLES OF THE RAKE SUPPORT.

* 1/4-14 X 1 1/4" SHOULDER (24" C.C.) (NOT BY CHIEF) PRE-GLUED THERMAL SPACER

PURLIN STC/MSC ROOF PANEL PURLIN CLOSURE (GPC) PANEL CLIP w/FASTENERS

?

PURLIN

RAKE ANGLE (A-20-B) #12-14 X 1" PANCAKE HEAD (2 PER PURLIN) RAKE SUPPORT (A-20-T)

(2) 1/8" X 3/8" BLIND RIVETS (TYP.)

(2) #12-14 X 1 1/4"' PER CLOSURE

THERMAL SPACER

(NOT BY CHIEF)

#12-14 X 1 1/4" (12" C.C.)

PURLIN CLOSURE CLIP (GCC-1) (FIELD MODIFY CLIP AS REQ'D) (2) 1/8" X 3/8" BLIND RIVETS TO CONNECT EACH CLIP TO EACH PURLIN CLOSURE (2) #12-14 X 1 1/4" TO CONNECT EACH CLIP TO EACH PURLIN

#12-14 X 1 1/4" (12" C.C.) (TRIM COLOR)

TOP VIEW

(2)1/4-14 X 7/8"

1/4-14 X 7/8" (12" C.C.) GABLE EXPANSION TRIM (GET) GABLE TRIM SUPPORT (GTS) (10'-0" C.C.) #12-14 X 1" PANCAKE HEAD (2 PER PURLIN) GABLE EXTENSION CHANNEL (GEC)

NOTE: · Purlin closure is to be field cut between eave struts and purlins. · Closure clips may need to be field cut to fit in purlin and staggered so #12-14 X 1 1/4" fasteners don't interfere.

#12-14 X 1 1/4" (6" C.C. for CS PANEL) (12" C.C. for AP PANEL)

CS SOFFIT PANEL 1/4-14 X 7/8" (12" C.C.)

**

HIGH PROFILE TRIM-SOFFITED GABLE EXT STC/ MSC

INSIDE CLOSURE ***

EAVE STRUT

#12-14 X 1 1/4" AT EACH PURLIN ROW (WALL COLOR)

1/4-14 X 7/8" (12" C.C.) RAKE ANGLE (A-20-B)

(2) #12-14 X 1 1/4" (2) 1/8" X 3/8" BLIND RIVETS PURLIN CLOSURE CLIPS (GCC1)

JAMB TRIM (JT)

WALL PANEL

*** DRAFTING NOTE: INSIDE CLOSURE MUST BE PROVIDED ON BUILDINGS WITH LINER INSULATION SYSTEM.

#12-14 X 1" PANCAKE HEAD EACH PURLIN EXTENSION FLASHING (EFCP) **

PANEL CAP TRIM (SCT)

L OR H SYSTEM

TRIM TYPE EFCP ECHP

PURLIN SIZE

EFCP = EXTENSION FLASHING HIGH PROFILE ECHP = EXT. FLASHING HIGH PROFILE

PURLIN CLOSURE INSTALLATION

8

HIGH HIGH

10

Made with FlippingBook flipbook maker