High Profile Trim

MVF-MVP Gable Ext Tail End w High Profile Trim-CS Soffit and Thermal Spacer

1

PURLIN

PURLIN CLOSURE AT RIDGE IS TO BE FIELD CUT AND FASTENED TOGETHER WITH (2) 1/8" X 3/8" BLIND RIVETS.

GABLE EXTENSION DIMENSION

PURLIN CLOSURE (GPC2 OR GPC3) (TYP) (2) PURLIN CLOSURE CLIPS (GCC1) AT EACH PURLIN CLOSURE (2) #12-14 X 1 1/4" EACH CLIP (2) 1/8" X 3/8" BLIND RIVETS (EACH CLIP)

CLOSURE CLIPS (GCC-1) (TYP.)

#12-14 X 1 1/4" (12" C.C.) EXTENSION FLASHING (EFCP) #12-14 X 1" PANCAKE HEAD EACH PURLN GABLE EXTENSION CHANNEL (GEC) 1/4-14 X 7/8" (12" C.C.) GABLE TRIM SUPPORT (GTS) (10'-0" C.C.) GABLE EXPANSION TRIM (GET) #12-14 X 1 1/4" (12" C.C.) (TRIM COLOR) (2) 1/4-14 X 7/8" PANEL CLIP w/FASTENERS GABLE TRIM (GTVH) RAKE ANGLE (A-20-B) (2) #12-14 X 1 1/4" (WALL COLOR) EACH CLIP CLIP LOCATION FROM SL ROOF PANEL CUT BACK DIMENSION **

BL

PURLIN CLOSURE (TYP.)

* 1/4-14 X 1 1/4" WT (12" C.C.) DOUBLE BEAD TAPE MASTIC DOUBLE BEAD TAPE MASTIC

* NOTE: THIS FASTENER MUST NOT HIT THE PURLIN.

PANEL CLIP w/FASTENERS

1 3

4 "

THERMAL SPACER

(NOT BY CHIEF)

#12-14 X 1 1/4" (2 EACH PURLIN) (WALL COLOR)

PURLIN

1"

PURLIN

MVF/MVP ROOF PANEL PURLIN CLOSURE (GPC)

PRE-GLUED THERMAL SPACER (NOT BY CHIEF)

(2) 1/8" X 3/8" BLIND RIVETS (TYP.)

(2) #12-14 X 1 1/4"' PER CLOSURE

PURLIN CLOSURE CLIP (GCC-1) (FIELD MODIFY CLIP AS REQ'D) (2) 1/8" X 3/8" BLIND RIVETS TO CONNECT EACH CLIP TO EACH PURLIN CLOSURE (2) #12-14 X 1 1/4" TO CONNECT EACH CLIP TO EACH PURLIN

TOP VIEW

NOTE: · Purlin closure is to be field cut between eave struts and purlins. · Closure clips may need to be field cut to fit in purlin and staggered so #12-14 X 1 1/4" fasteners don't interfere.

#12-14 X 1 1/4" (6" C.C. for CS PANEL) (12" C.C. for AP PANEL)

CS SOFFIT PANEL 1/4-14 X 7/8" (12" C.C.)

INSIDE CLOSURE ***

#12-14 X 1 1/4" AT EACH PURLIN ROW (WALL COLOR)

EAVE STRUT

1/4-14 X 7/8" (12" C.C.) PANEL CAP TRIM (SCT) RAKE ANGLE (A-20-B)

(2) #12-14 X 1 1/4" (2) 1/8" X 3/8" BLIND RIVETS PURLIN CLOSURE CLIPS (GCC1)

JAMB TRIM (JT)

TRIM TYPE EFCP ECHP

PURLIN SIZE

L OR H SYSTEM

**

HIGH PROFILE TRIM-SOFFITED GABLE EXT MVF/MVP

WALL PANEL

8

HIGH HIGH

*** DRAFTING NOTE: INSIDE CLOSURE MUST BE PROVIDED ON BUILDINGS WITH LINER INSULATION SYSTEM.

10

PURLIN CLOSURE INSTALLATION

EFCP = EXTENSION FLASHING HIGH PROFILE ECHP = EXT. FLASHING HIGH PROFILE