DETAILS HIGH EAVE HEIGHT CHANGE TRIM * WALL PANEL
SL
* Provide air gap of 1/4" minimum at bottom of panel to avoid corrosion.
HEIGHT CHANGE TRIM (LHET) #12-14 X 1 1/4" (6" C.C. for CS PANEL) (12" C.C. for AP PANEL) INSIDE CLOSURE
1/4"
TRI-BEAD TAPE MASTIC 1/4"-14 X 7/8" WT
1/4"-14 X 1 1/4" WT (9 PER PANEL)
OUTSIDE CLOSURE PRE-CUT TRI-BEAD TAPE MASTIC
ROOF CLIP AND FASTENERS (SEE ROOF PANELING PLAN)
STC PANEL
BACK-UP PLATE
INSULATION
PURLIN
4"
8"
HEIGHT CHANGE TRIM
1½"
1½"
1½"
1½"
5 ¼"
24" Panels = 4 SPACES AT 5 ¼" 18" Panels = 3 SPACES AT 5"
Refer to erection drawing General Details for expansion joint installation instructions if required.
1/4"-14 X 7/8" WT
OUTSIDE CLOSURE
HEIGHT CHANGE TRIM FASTENER SPACING