Wall Panel and Trim
AP Trim Only 4-Sided Opening w Sill Flashing-WFS
AP Panel - Trim Only 4-Sided Opening with Sill Flashing – WFS
Installation Steps: 1. Install Wrap Plate, if applicable. 2. Liner Cover Trim(LCT), if applicable. Use with Liner/Backer. Refer to Liner or Partition Panel Drawings. 3. Sill Trim Flashing (WFS), slit and fold up at jamb. 4. Header Trim (HTT). 7. Sheeting Support (SSP) 8. Notch and slit wall panel. 6. Place wall panel over trims with foam inside closure full width of header and sill. 7. Jamb Trim (JTA). Notes: · Drill Ø1/8" holes for Blind Rivets. · Rivets spaced at 7'-0" C.C. are temporary fasteners. · ** #12-14 X 1-1/4", Blanket Insulation <=4" thickness. · ** #12-14 X 2", Blanket Insulation >4" thickness.
INSIDE CLOSURE
Head Trim (HTT) lapped 4 1/4" min. past edge of window jamb. Flush with end of Jamb Trim (JTA).
Optional urethane caulk at HTT end. (NOT BY CHIEF)
HEADER TRIM (HTT)
2 1/4" X 1/4" PANEL NOTCH
SHEETING SUPPORT (SSP) JAMB TRIM (JTA) WALL PANEL
2" PANEL SLIT
LINER COVER TRIMS
FIELD VERIFY WFS OFFSET
Optional urethane caulk at panel slit and notch. Caulk under JTA. (NOT BY CHIEF) (TYP.)
2" SLIT
2" X 1/4" NOTCH
Optional urethane sealant at WFS end (NOT BY CHIEF)
For best weathertightness performance, JTA/SSP and Head Trim assembly should land in flat of panel. Layout, verify, and consider field locating framed opening as necessary. If this condition cannot be achieved, special field trim modifications, and/or additional urethane caulking Not By Chief may be required.
4 1/4" TO EDGE OF WINDOW JAMB
NOTCH AND SLIT WALL PANEL FOR EXTENSION OF TRIM. (TYP.) ** #12-14 X 1 1/4" (12" C.C.) (TYP.) WALL PANEL SILL TRIM FLASHING (WFS) 1/8" X 3/8" BLIND RIVET (12" C.C.)
JAMB TRIM (JTA)
FLAT OF
EDGE OF JAMB HEAD TRIM
Optional Urethane caulk around 2" panel slit and under JTA (NOT BY CHIEF) (TYP.)
END OF JAMB TRIM (JTA)
TRIM DETAIL AT CORNERS
WALL PANEL SLIT
(Window not Shown)
BL
OPENING WIDTH
1/8" X 3/8" BLIND RIVET, (18" C.C.) WITH LINER COVER TRIM (LCT)
FRAMING (NOT BY CHIEF)
1/8" X 3/8" BLIND RIVET (7'-0" C.C.)
**#12-14 X 1 1/4" (12" C.C.)
LINER COVER TRIM (LCT1)
FRAMING (NOT BY CHIEF)
INSIDE CLOSURE
2 1 4 "
* 1 4 "
1/8" X 3/8" BLIND RIVET (7'-0" C.C.) (TYP.) **#12-14 X 1 1/4" (12" C.C.)
* Provide air gap of 1/4" min. at bottom of panel to avoid corrosion.
1/8" X 3/8" BLIND RIVET (3'-0" C.C.)
LINER COVER TRIM (LCT2)
HEADER TRIM (HTT)
LINER COVER TRIM (LCT1)
GIRT/SILL INSIDE CLOSURE **#12-14 X 1 1/4" (12" C.C.) WALL PANEL (TYP.) SILL TRIM FLASHING (WFS) SPECIAL PLATE. REFER TO FRAMING PLANS FOR PIECE MARK (PL) LINER COVER TRIM (LCT2)
BL
OPENING
1/8" X 3/8" BLIND RIVET (3'-0" C.C.) 1/8" X 3/8" BLIND RIVET (12" C.C.)
**#12-14 X 1 1/4" (12" C.C.)
WALL PANEL
JAMB TRIM (JTA) 1/4-14 X 7/8" (12" C.C.)
CUT RIB AS NEEDED
SHEETING SUPPORT (SSP)
FRAMING (NOT BY CHIEF)
OPENING DETAILS AT HEADER AND SILL
FRAMED OPENING DETAILS AT JAMB
Made with FlippingBook - professional solution for displaying marketing and sales documents online