AP Trim Only 4-Sided Opening w Jamb Trim-JT

AP Panel - Trim Only 4-Sided Opening with Sill Jamb Trim – JT

Installation Steps: 1. Install Wrap Plate, if applicable. 2. Liner Cover Trim(LCT), if applicable. Use with Liner/Backer. Refer to Liner or Partition Panel Drawings. 3. Sill Jamb Trim (JT), slit and fold up at jamb. 4. Header Trim (HTT). 5. Sheeting Support (SSP) 6. Notch and slit wall panel. 7. Place wall panel over trims with foam inside closure full width of header and sill. 8. Jamb Trim (JTA). Notes: · Drill Ø1/8" holes for Blind Rivets. · Rivets spaced at 7'-0" C.C. are temporary fasteners. · ** #12-14 X 1-1/4", Blanket Insulation <=4" thickness. · ** #12-14 X 2", Blanket Insulation >4" thickness.

Head Trim (HTT) lapped 4 1/4" min. past edge of window jamb. Flush with end of Jamb Trim (JTA).

INSIDE CLOSURE Optional urethane caulk at HTT end. (NOT BY CHIEF)

HEADER TRIM (HTT)

2 1/4" X 1/4" PANEL NOTCH

SHEETING SUPPORT (SSP) JAMB TRIM (JTA) WALL PANEL

2" PANEL SLIT

Opitonal Urethane caulk at JT end. (NOT BY CHIEF) LINER COVER TRIMS

Optional urethane caulk at panel slit and notch. Caulk under JTA. (NOT BY CHIEF) (TYP.)

REDUCE LEG LENGTH

2" SLIT

2" X 1/4" NOTCH

For best weathertightness performance, JTA/SSP and Head Trim assembly should land in flat of panel. Layout, verify, and consider field locating framed opening as necessary. If this condition cannot be achieved, special field trim modifications, and/or additional urethane caulking Not By Chief may be required.

4 1/4" TO EDGE OF WINDOW JAMB

OPTIONAL JAMB TRIM FOLD AT END

SILL JAMB TRIM (JT)

NOTCH AND SLIT WALL PANEL FOR EXTENSION OF TRIM. (TYP.) ** #12-14 X 1 1/4" (12" C.C.) (TYP.) WALL PANEL Optional urethane caulk behind JT (NOT BY CHIEF)

JAMB TRIM (JTA)

FLAT OF

EDGE OF JAMB HEAD TRIM

Optional Urethane caulk around 2" panel slit and under JTA (NOT BY CHIEF) (TYP.)

END OF JAMB TRIM (JTA)

TRIM DETAIL AT CORNERS

WALL PANEL SLIT

(Window not Shown)

BL

OPENING WIDTH

1/8" X 3/8" BLIND RIVET, (18" C.C.) WITH LINER COVER TRIM (LCT)

FRAMING (NOT BY CHIEF)

1/8" X 3/8" BLIND RIVET (7'-0" C.C.)

LINER COVER TRIM (LCT1)

**#12-14 X 1 1/4" (12" C.C.)

FRAMING (NOT BY CHIEF)

INSIDE CLOSURE

2 1 4 "

* Provide air gap of 1/4" min. at bottom of panel to avoid corrosion.

* 1 4 "

1/8" X 3/8" BLIND RIVET (7'-0" C.C.) (TYP.) **#12-14 X 1 1/4" (12" C.C.)

1/8" X 3/8" BLIND RIVET, 18" C.C. WITH COVER TRIM (LCT)

LINER COVER TRIM (LCT2)

HEADER TRIM (HTT) WINDOW BY CHIEF

LINER COVER TRIM (LCT1)

SPECIAL PLATE. REFER TO FRAMING PLANS FOR PIECE MARK (PL) LINER COVER TRIM (LCT2)

BL

OPENING

**#12-14 X 1 1/4" (12" C.C.)

WALL PANEL

1/8" X 3/8" BLIND RIVET, 18" C.C. WITH COVER TRIM (LCT)

JAMB TRIM (JTA) 1/4-14 X 7/8" (12" C.C.)

CUT RIB AS NEEDED

SILL JAMB TRIM (JT)

INSIDE CLOSURE **#12-14 X 1 1/4" (12" C.C.)

SHEETING SUPPORT (SSP)

FRAMING (NOT BY CHIEF)

Urethane caulk behind JT (NOT BY CHIEF)

1/8" X 3/8" BLIND RIVET (7'-0" C.C.)

WALL PANEL (TYP.)

OPENING DETAILS AT HEADER AND SILL

FRAMED OPENING DETAILS AT JAMB