Wall Panel and Trim

CS Window or 4-Sided Opening w Jamb Trim–JT

CS Panel - Window Not by Chief or 4-Sided Opening with Jamb Trim – JT

Notes: ·

LINER COVER TRIM (LCT1)

Drill Ø1/8" holes for Blind Rivets.

· Rivets spaced at 7'-0" C.C. are temporary fasteners. · ** #12-14 X 1-1/4", Blanket Insulation <=4" thickness. · ** #12-14 X 2", Blanket Insulation >4" thickness. · LCT1 or LCT2 used with Liner/Backer. Refer to Liner or Partition Panel Dwg.

1/8" X 3/8" BLIND RIVET, 18" C.C. WITH LINER COVER TRIM (LCT) JAMB

OPENING WIDTH

OPENING WIDTH

JAMB

LINER COVER TRIM (LCT2)

BL

JAMB TRIM (JT) 1/8" X 3/8" BLIND RIVET (18" C.C.) LINER COVER TRIM (LCT2)

1/8" X 3/8" BLIND RIVET (7'-0" C.C.)

JAMB TRIM (JT)

BL

FRAMED OPENING DETAILS AT JAMB

WALL PANEL **#12-14 X 1 1/4" (12" C.C.) COVER TRIM (COT)

HEADER TRIM WITH TROUGH (HTT) SPECIAL PLATE. REFER TO FRAMING PLANS FOR PIECE MARK (PL) LINER COVER TRIM (LCT2) 1/8" X 3/8" BLIND RIVET (7'-0" C.C.) GIRT #12-14 X 1" PANCAKE HEAD (36" C.C.) (TYP.)

BL

TRIM DETAILS AT JAMB

1/8" X 3/8" BLIND RIVET, 18" C.C. WITH COVER TRIM (LCT)

BL

**#12-14 X 1 1/4" (6" C.C.)

ZEE GIRT

INSIDE CLOSURE

SPECIAL PLATE. REFER TO FRAMING PLANS FOR PIECE MARK (PL)

LINER COVER TRIM (LCT1)

WALL PANEL

OPENING

1

4 "

JAMB TRIM (JT)

HEADER TRIM WITH TROUGH (HTT) LINER COVER TRIM (LCT2)

1/8" x 3/8" BLIND RIVET (7'-0" C.C.)

GIRT/SILL

OPENING HEIGHT

CEE HEADER

Provide air gap of 1/4" min. at bottom of panel to avoid corrosion.

OPENING DETAILS AT HEADER AND SILL

1

4 "

TRIM DETAILS AT HEADER

3"

NOTCH WALL PANEL FOR EXTENSION OF TRIM.

LINER COVER TRIM (LCT2)

BL

HEADER TRIM WITH TROUGH (HTT)

JAMB TRIM (JT)

OPENING HEIGHT

COVER TRIM (COT)

JAMB TRIM (JT)

INSIDE CLOSURE **#12-14 X 1 1/4" (6 "C.C.) WALL PANEL

JAMB TRIM (JT)

NOTCH WALL PANEL FOR EXTENSION OF TRIM.

3"

GIRT/SILL

TRIM (JT) DETAILS AT SILL

TRIM DETAIL AT CORNER

Made with FlippingBook - professional solution for displaying marketing and sales documents online