Wall Panel and Trim
CS Window or 4-Sided Opening w Sill Flashing–WFS
CS Panel - Window Not by Chief or 4-Sided Opening with Sill Flashing – WFS
Notes: ·
Drill Ø1/8" holes for Blind Rivets.
LINER COVER TRIM (LCT1)
· Rivets spaced at 7'-0" C.C. are temporary fasteners. · ** #12-14 X 1-1/4", Blanket Insulation <=4" thickness. · ** #12-14 X 2", Blanket Insulation >4" thickness. · LCT1 or LCT2 used with Liner/Backer. Refer to Liner or Partition Panel Dwg.
1/8" X 3/8" BLIND RIVET, 18" C.C. WITH LINER COVER TRIM (LCT) JAMB
OPENING WIDTH
OPENING WIDTH
JAMB
BL
LINER COVER TRIM (LCT2)
1/8" X 3/8" BLIND RIVET (7'-0" C.C.) (TYP.)
JAMB TRIM (JT)
LINER COVER TRIM (LCT2)
BL
FRAMED OPENING DETAILS AT JAMB
JAMB TRIM (JT) 1/8" X 3/8" BLIND RIVET (18" C.C.) (TYP.)
WALL PANEL **#12-14 X 1 1/4" (12" C.C.) COVER TRIM (COT)
HEADER TRIM WITH TROUGH (HTT) SPECIAL PLATE. REFER TO FRAMING PLANS FOR PIECE MARK (PL) LINER COVER TRIM (LCT2) SILL TRIM FLASHING (WFS) 1/8" X 3/8" BLIND RIVET (7'-0" C.C.) GIRT #12-14 X 1" PANCAKE HEAD (36" C.C.) (TYP.)
BL
TRIM DETAILS AT JAMB
1/8" X 3/8" BLIND RIVET, 36" C.C.
BL
ZEE GIRT
**#12-14 X 1 1/4" (6" C.C.)
SPECIAL PLATE. REFER TO FRAMING PLANS FOR PIECE MARK (PL)
INSIDE CLOSURE WALL PANEL
LINER COVER TRIM (LCT1)
OPENING
1
4 "
HEADER TRIM WITH TROUGH (HTT) LINER COVER TRIM (LCT2)
1
4 "
GIRT/SILL
OPENING HEIGHT
CEE HEADER
OPENING DETAILS AT HEADER AND SILL
Provide air gap of 1/4" min. at bottom of panel to avoid corrosion.
TRIM DETAILS AT HEADER
3"
LINER COVER TRIM (LCT1)
NOTCH WALL PANEL FOR EXTENSION OF TRIM.
BL
SILL TRIM FLASHING (WFS)
1/8" X 3/8" BLIND RIVET (12" C.C.)
OPENING HEIGHT
HEADER TRIM WITH TROUGH (HTT)
1/4-14 X 7/8" (12" C.C.)
COVER TRIM (COT)
JAMB TRIM (JT)
INSIDE CLOSURE **#12-14 X 1 1/4" (6" C.C.) WALL PANEL
NOTCH WALL PANEL FOR EXTENSION OF TRIM.
SILL TRIM FLASHING (WFS)
GIRT/SILL
3"
TRIM DETAIL AT SILL (WFS)
TRIM DETAIL AT CORNER
Made with FlippingBook - professional solution for displaying marketing and sales documents online