Wall Panel and Trim

CS Trim Only 4-Sided Opening w Sill Flashing-WFS

CS Panel - Trim Only 4-Sided Opening with Sill Flashing – WFS

Header Trim (HTT) and Sill Trim (JT) lapped 3" min. past flat of Jamb Trim (JT). Flush with Cover Trim (COT).

Installation Steps: 1. Install Wrap Plate, if applicable. 2. Liner Cover Trim(LCT), if applicable. Use with Liner/Backer. Refer to Liner or Partition Panel Drawings. 3. Sill Trim Flashing (WFS), slit and fold up at jamb. 4. Jamb Trim (JT) with notch at header. 5. Header Trim (HTT). 6. Notch and slit wall panel. 7. Place wall panel over trims with foam inside closures. 8. Cover Trim (COT). Notes: · Drill Ø1/8" holes for Blind Rivets. · Rivets spaced at 7'-0" C.C. are temporary fasteners. · ** #12-14 X 1-1/4", Blanket Insulation <=4" thickness. · ** #12-14 X 2", Blanket Insulation >4" thickness.

2" JAMB TRIM NOTCH

2" X 1/4" PANEL NOTCH

1" PANEL SLIT

JAMB TRIM (JT) INSIDE CLOSURE HEADER TRIM (HTT)

LINER COVER TRIMS

FIELD VERIFY WFS OFFSET

For best weathertightness performance, JT/COT and Head/Sill Trim assembly should land in flat of panel. Layout, verify, and consider field locating framed opening as necessary. If this condition cannot be achieved, special field trim modifications, omitting COT trim, and/or additional urethane caulking Not By Chief may be required.

1" SLIT

2" X 1/4" NOTCH

3" TO FLAT OF JAMB TRIM

2" JAMB TRIM NOTCH

COVER TRIM (COT)

NOTCH AND SLIT WALL PANEL FOR EXTENSION OF TRIM. (TYP.) **#12-14 X 1 1/4" (6" C.C.) (TYP.) WALL PANEL SILL TRIM FLASHING (WFS) 1/8" X 3/8" BLIND RIVET (12" C.C.)

Optional Urethane caulk around 1" panel slit and under COT (NOT BY CHIEF) (TYP.)

FLAT OF JAMB TRIM FLAT OF HEAD TRIM

WALL PANEL SLIT AND NOTCH (Typical at Sill)

TRIM DETAIL AT CORNERS

BL

1/8" X 3/8" BLIND RIVET, (18" C.C.) WITH LINER COVER TRIM (LCT) FRAMING (NOT BY CHIEF) 1/8" X 3/8" BLIND RIVET (7'-0" C.C.) (TYP.)

1/8" X 3/8" BLIND RIVET (7'-0" C.C.)

FRAMING (NOT BY CHIEF)

**#12-14 X 1 1/4" (6" C.C.)

LINER COVER TRIM (LCT1)

INSIDE CLOSURE

* 1 4 " * Provide air gap of 1/4" min. at bottom of panel to avoid corrosion.

1/8" X 3/8" BLIND RIVET, 18" C.C. WITH COVER TRIM (LCT)

OPENING WIDTH

HEADER TRIM WITH TROUGH (HTT)

LINER COVER TRIM (LCT2)

LINER COVER TRIM (LCT1)

BL

**#12-14 X 1 1/4" (12" C.C.) WALL PANEL

JAMB TRIM (JT)

OPENING

LINER COVER TRIM (LCT2)

CUT RIB AS NEEDED

FRAMING (NOT BY CHIEF) 1/8" X 3/8" BLIND RIVET, 18" C.C. WITH COVER TRIM (LCT) 1/8" x 3/8" BLIND RIVET (12" C.C.)

1/8" X 3/8" BLIND RIVET (18" C.C.) (TYP.) COVER TRIM (COT)

SILL TRIM FLASHING (WFS) INSIDE CLOSURE ** #12-14 X 1 1/4" (6" C.C.) WALL PANEL (TYP.)

OPENING DETAILS AT HEADER AND SILL

FRAMED OPENING DETAILS AT JAMB