Wall Panel and Trim

CS Window or 4-Sided Opening w Trim Only

CS Panel - Window or 4-Sided Opening with Trim Only

BL

LINER COVER TRIM (LCT1)

FRAMING (NOT BY CHIEF)

**#12-14 X 1 1/4" (6" C.C.) INSIDE CLOSURE WALL PANEL HEADER TRIM WITH TROUGH (HTT)

OPENING WIDTH

LINER COVER TRIM (LCT2)

1

4 "

BL

JAMB TRIM (JT)

FRAMING (NOT BY CHIEF)

WALL PANEL **#12-14 X 1 1/4" (12" C.C.) COVER TRIM (COT) 1/8" X 3/8" BLIND RIVET (18" C.C.)

LINER COVER TRIM (LCT2) LINER COVER TRIM (LCT1) Provide air gap of 1/4" min. at bottom of panel to avoid corrosion.

OPENING HEIGHT

TRIM ONLY HEADER DETAILS

TRIM ONLY JAMB DETAILS

Notes: ·

LINER COVER TRIM (LCT2)

BL

LINER COVER TRIM (LCT1)

Drill Ø1/8" holes for Blind Rivets.

· Rivets spaced at 7'-0" C.C. are temporary fasteners. · ** #12-14 X 1-1/4", Blanket Insulation <=4" thickness. · ** #12-14 X 2", Blanket Insulation >4" thickness. · LCT1 or LCT2 used with Liner/Backer. Refer to Liner or Partition Panel Dwg.

JAMB TRIM (JT)

FRAMING (NOT BY CHIEF)

INSIDE CLOSURE **#12-14 X 1 1/4" (12 "C.C.) WALL PANEL

3"

JAMB TRIM (JT)

LINER COVER TRIM (LCT1)

NOTCH WALL PANEL FOR EXTENSION OF TRIM.

HEADER TRIM WITH TROUGH (HTT)

BL

SILL TRIM FLASHING (WFS)

1/8" X 3/8" BLIND RIVET (12" C.C.)

JAMB TRIM (JT)

COVER TRIM (COT)

1/4-14 X 7/8" (12" C.C.)

INSIDE CLOSURE **#12-14 X 1 1/4" (6" C.C.)

NOTCH WALL PANEL FOR EXTENSION OF TRIM.

TRIM AT SILL (JT/ WFS)

SILL TRIM (WFS)

WALL PANEL

3"

TRIM DETAILS AT SILL

TRIM DETAIL AT CORNER