Wall Panel and Trim

AP Metal Bldg Walkdoor-PA-SF

AP Panel- Metal Building Walkdoor - Pre-Assembled (by Chief) or Self-Framing Not by Chief Refer to Order Documents for Doors Supplied by Chief

Installation Steps: 1. Install Wrap Plate. 2. Door. 3. Liner Cover Trim(LCT), if applicable. Use with Liner/Backer. Refer to Liner or Partition Panel Drawings. 4. Sheeting Support (SSP) 5. Header Trim (HTT). 6. Notch and slit wall panel. 7. Place wall panel over trims with foam inside closure full width of header. 8. Jamb Trim (JTA). Notes: · Drill Ø1/8" holes for Blind Rivets.

Head Trim (HTT) lapped 4 1/4" min. past edge of door frame. Flush with end of Jamb Trim (JTA).

INSIDE CLOSURE Optional urethane caulk at HTT end. (NOT BY CHIEF)

2 1/4" X 1/4" PANEL NOTCH

HEADER TRIM (HTT)

2" PANEL SLIT

SHEETING SUPPORT (SSP)

· Rivets spaced at 7'-0" C.C. are temporary fasteners. · ** #12-14 X 1-1/4", Blanket Insulation <=4" thickness. · ** #12-14 X 2", Blanket Insulation >4" thickness.

Optional urethane caulk at panel slit and notch. Caulk under JTA. (NOT BY CHIEF)

2" SLIT

WALL PANEL

2 1/4" X 1/4" NOTCH

For best weathertightness performance, JTA/SSP and Head Trim assembly should land in flat of panel. Layout, verify, and consider field locating framed opening as necessary. If this condition cannot be achieved, special field trim modifications, and/or additional urethane caulking Not By Chief may be required.

JAMB TRIM (JTA)

DOOR JAMB

DOOR FRAME

EDGE OF DOOR FRAME FLAT OF HEAD TRIM

JAMB TRIM (JTA)

END OF JAMB TRIM (JTA)

TRIM DETAIL AT CORNERS

WALL PANEL SLIT

LINER COVER TRIM (LCT1 OR LCT2) (Field modify as req'd) 1/8" X 3/8" BLIND RIVET (18" C.C.) (TYP.)

WALL PANEL

#12-14 X 1" PANCAKE HEAD FASTENER (36" C.C.)

BL

OPENING WIDTH

**#12-14 X 1 1/4" (12" C.C.) INSIDE CLOSURE HEADER TRIM (HTT) 1/8" X 3/8" BLIND RIVET (7'-0" C.C.)

ZEE GIRT

1/8" X 3/8" BLIND RIVET (3'-0" C.C.) TYP. SPECIAL PLATE. REFER TO FRAMING PLANS FOR PIECE MARK (PL)

DOOR SUB FRAME

NOMINAL DOOR OPENING

**#12-14 X 1 1/4" (12" C.C.)

* 1 4 "

LINER COVER TRIM (LCT1 OR LCT2) (Field modify as req'd)

DOOR FRAME

BL

1

2 " MIN.

CUT RIB AS NEEDED

SHEETING SUPPORT (SSP) WALL PANEL 1/4-14 X 7/8" (12" C.C.)

***1/8"-3/4"

DOOR FRAME

OPENING HEIGHT

NOMINAL

DOOR OPENING

* Provide air gap of 1/4" min. at bottom of panel to avoid corrosion.

*** Locate JTA/SSP trim to cover door frame avoiding interference with latch, door and hinges.

JAMB TRIM (JTA)

CEE HEADER

WALKDOOR HEADER TRIM DETAILS

WALKDOOR JAMB TRIM DETAILS

Made with FlippingBook - professional solution for displaying marketing and sales documents online