High Profile Trim

STC-MSC Gable Ext Tail End High Profile Trim-Field Bend Leg NO Soffit and Thermal Spacer

1

PURLIN

PURLIN CLOSURE AT RIDGE IS TO BE FIELD CUT AND FASTENED TOGETHER WITH (2) 1/8" X 3/8" BLIND RIVETS.

PURLIN CLOSURE (GPC2 OR GPC3) (TYP) (2) PURLIN CLOSURE CLIPS (GCC1) AT EACH PURLIN CLOSURE (2) #12-14 X 1 1/4" EACH CLIP (2) 1/8" X 3/8" BLIND RIVETS (EACH CLIP)

GABLE EXTENSION DIMENSION

*NOTE:IT IS IMPORTANT THAT 1/4-14 X 1 1/4" SHOULDER FASTENERS ARE INSTALLED THROUGH THE CENTER OF THE SLOTTED HOLES OF THE RAKE SUPPORT.

CLOSURE CLIPS (GCC-1) (TYP.)

PURLIN CLOSURE (TYP.)

BL

#12-14 X 1 1/4" (12" C.C.) (TRIM COLOR) * 1/4-14 X 1 1/4" SHOULDER (24" C.C.) RAKE SUPPORT (A-20-T) GABLE TRIM (GTMH) NOTE: FIELD FORM A 3" VERTICAL ROOF PANEL LEG TO FIT FINAL DIMENSION

#12-14 X 1 1/4" (12" C.C.) #12-14 X 1" PANCAKE HEAD EACH PURLIN (NOT BY CHIEF) PRE-GLUED THERMAL SPACER TRI-BEAD TAPE SEALER 1/4-14 X 1 1/4" WT (12" C.C.)

STC/MSC ROOF PANEL

PURLIN

THERMAL SPACER

(NOT BY CHIEF)

PURLIN CLOSURE (GPC) PANEL CLIP w/FASTENERS PURLIN

(2) 1/8" X 3/8" BLIND RIVETS (TYP.)

(2) #12-14 X 1 1/4"' PER CLOSURE

(2) 1/4-14 X 7/8"

TOP VIEW

GABLE TRIM SUPPORT (GTS) (10'-0" C.C.)

#12-14 X 1" PANCAKE HEAD (2 EACH PURLIN)

GABLE EXPANSION TRIM (GET)

1/4-14 X 7/8" (12" C.C.)

#12-14 X 1 1/4" (6" C.C. for CS PANEL) (12" C.C for AP PANEL)

GABLE EXTENSION CHANNEL (GEC) EXTENSION FLASHING (EF) #12-14 X 1" PANCAKE HEAD (2 PER PURLIN)

NOTE: · Purlin closure is to be field cut between eave struts and purlins. · Closure clips may need to be field cut to fit in purlin and staggered so #12-14 X 1 1/4" fasteners don't interfere.

**

INSIDE CLOSURE

1/4-14 X 7/8" (12" C.C.) PANEL CAP TRIM (SCT) RAKE ANGLE (A-20-B) FIELD NOTCH AS REQUIRED AT EACH PURLIN ROW

PURLIN CLOSURE CLIP (GCC-1) (FIELD MODIFY CLIP AS REQ'D) (2) 1/8" X 3/8" BLIND RIVET TO CONNECT EACH CLIP TO EACH PURLIN CLOSURE (2) #12-14 X 1 1/4" TO CONNECT EACH CLIP TO EACH PURLIN

EAVE STRUT

***

*** HIGH PROFILE TRIM UNSOFFITED GABLE EXT STC / MSC

L OR H SYSTEM

TRIM TYPE

PURLIN SIZE

(2) #12-14 X 1 1/4" (2) 1/8" X 3/8" BLIND RIVETS PURLIN CLOSURE CLIPS (GCC1)

8

HIGH HIGH

EF

10

EFHP

** DRAFTING NOTE: INSIDE CLOSURE MUST BE PROVIDED ON BUILDINGS WITH LINER INSULATION SYSTEM.

EF- EXTENSION FLASHING EFHP - EXTENSION FLASHING HIGH PROFILE

PURLIN CLOSURE INSTALLATION

WALL PANEL

Made with FlippingBook flipbook maker