MVF MVP Roof Panel
MVF-MVP Inset Gable Tail End Height Change w Cut Roof Panel and Panel Below
* Field cut bottom of wall panels to match roof slope. Provide air gap of 1/4" min. at bottom of panel to avoid corrosion.
PURLIN
PURLIN CLOSURE AT RIDGE IS TO BE FIELD CUT AND FASTENED TOGETHER WITH (2) 1/8" X 3/8" BLIND RIVETS.
PURLIN CLOSURE (GPC2 OR GPC3) (TYP) (2) PURLIN CLOSURE CLIPS (GCC1) AT EACH PURLIN CLOSURE (2) #12-14 X 1 1/4" EACH CLIP (2) 1/8" X 3/8" BLIND RIVETS (EACH CLIP)
L ROOF PANEL CUT BACK DIM. CLIP LOCATION FROM B
CLOSURE CLIPS (GCC-1) (TYP.)
PURLIN CLOSURE (TYP.)
*WALL PANEL (TYP.) INSIDE CLOSURE #12-14 x 1 1/4" (6" C.C. for CS PANEL) (12" C.C. for AP PANEL) RAKE ANGLE (A-20-L)
HEIGHT CHANGE TRIM NBOTTOM (GHVB HEIGHT CHANGE TRIM TOP (GHVT) (2) #12-14 x 1 1/4" (EACH CLIP) WALL COLOR
BL
2 1 4 "
1 1 2 "
DOUBLE BEAD TAPE MASTIC 1/4-14 x 1 1/4" WT (6" C.C.)** TAPE MASTIC
PURLIN
(2) 1/8" X 3/8" BLIND RIVETS (TYP.)
MVF/MVP ROOF PANEL RAKE ANGLE (A-20-B)
(2) #12-14 X 1 1/4"' PER CLOSURE
PURLIN
1
4 "
***
PRE-GLUED THERMAL SPACER (NOT BY CHIEF)
TOP VIEW
PANEL CLIP w/FASTENERS (REFER TO ROOF PANEL PLAN)
(2) #12-24 X 1 1/2" (36" C.C.) RAKE ANGLE (A-20) HEIGHT CHANGE RAFTER **NOTE: This fastener must not hit the purlin. #12-14 X 1 1/4" (2 EACH PURLIN) (WALL COLOR)
DOUBLE BEAD TAPE MASTIC
PANEL CLIP w/FASTENERS (REFER TO ROOF PANEL PLAN)
NOTE: · Purlin closure is to be field cut between eave struts and purlins. · Closure clips may need to be field cut to fit in purlin and staggered so #12-14 X 1 1/4" fasteners don't interfere.
PANELING CAP TRIM (SCT) 1/4-14 x 7/8" (12" C.C.) PURLIN CLOSURE (GPC__) (PURLIN CLOSURE CLIPS NOT SHOWN)
EAVE STRUT
(2) #12-14 X 1 1/4" (2) 1/8" X 3/8" BLIND RIVETS PURLIN CLOSURE CLIPS (GCC1)
***DRAFTING NOTE: Thermal spacer to be used with no insulation.
PURLIN CLOSURE INSTALLATION
Made with FlippingBook - Online catalogs