MVF MVP Roof Panel
MVF-MVP High Side Height Change w Zee Girt to Taller Building
INSIDE CLOSURE GIRT WALL PANEL
* For screw spacing refer to High Side Height Change detail in the MVF/MVP Roof Panel Erection manual.
*1/4-14 X 7/8" WT EXPANSION TRIM (LHET) #12-14 X 1 1/4" (6" C.C. for CS PANEL) (12" C.C. for AP PANEL)
BL
DOUBLE BEAD TAPE MASTIC
RIDGE CLOSURE
MVF/MVP ROOF PANEL PANEL CLIP w/FASTENERS (REFER TO ROOF PANEL PLAN) PRE-GLUED THERMAL SPACER (NOT BY CHIEF)
1
4 "
Provide air gap of 1/4" min. at bottom of panel to avoid corrosion.
**
3"
PURLIN DOUBLE BEAD TAPE MASTIC
**DRAFTING NOTE: Thermal spacer to be used with no insulation.
1/4-14 X 7/8" WT (7 PER PANEL)
Made with FlippingBook - Online catalogs