MVF MVP Roof Panel

MVF-MVP High Side Height Change w Zee Girt to Taller Building

INSIDE CLOSURE GIRT WALL PANEL

* For screw spacing refer to High Side Height Change detail in the MVF/MVP Roof Panel Erection manual.

*1/4-14 X 7/8" WT EXPANSION TRIM (LHET) #12-14 X 1 1/4" (6" C.C. for CS PANEL) (12" C.C. for AP PANEL)

BL

DOUBLE BEAD TAPE MASTIC

RIDGE CLOSURE

MVF/MVP ROOF PANEL PANEL CLIP w/FASTENERS (REFER TO ROOF PANEL PLAN) PRE-GLUED THERMAL SPACER (NOT BY CHIEF)

1

4 "

Provide air gap of 1/4" min. at bottom of panel to avoid corrosion.

**

3"

PURLIN DOUBLE BEAD TAPE MASTIC

**DRAFTING NOTE: Thermal spacer to be used with no insulation.

1/4-14 X 7/8" WT (7 PER PANEL)

Made with FlippingBook - Online catalogs