Wall Panel and Trim

AP Window by Chief

AP Panel - Window by Chief

Installation Steps: 1. Install Wrap Plate, if applicable. 2. Liner Cover Trim(LCT), if applicable. Use with Liner/Backer. Refer to Liner or Partition Panel Drawings. 4. Window 5. Sill Jamb Trim (JT), slit and fold up at jamb. 6. Header Trim (HTT). 7. Sheeting Support (SSP) 8. Notch and slit wall panel. 6. Place wall panel over trims with foam inside closure full width of header and sill. 7. Jamb Trim (JTA) Notes: · Drill Ø1/8" holes for Blind Rivets. · Rivets spaced at 7'-0" C.C. are temporary fasteners. · ** #12-14 X 1-1/4", Blanket Insulation <=4" thickness. · ** #12-14 X 2", Blanket Insulation >4" thickness.

Head Trim (HTT) lapped 4 1/4" min. past edge of window jamb. Flush with end of Jamb Trim (JTA).

INSIDE CLOSURE Optional urethane caulk at HTT end. (NOT BY CHIEF)

HEADER TRIM (HTT)

2 1/4" X 1/4" PANEL NOTCH

SHEETING SUPPORT (SSP)

2" PANEL SLIT

WALL PANEL

Optional urethane caulk at panel slit and notch. Caulk under JTA. (NOT BY CHIEF) (TYP.)

JAMB TRIM (JTA)

LINER COVER TRIMS

2" SLIT

2" X 1/4" NOTCH

For best weathertightness performance, JTA/SSP and Head Trim assembly should land in flat of panel. Layout, verify, and consider field locating framed opening as necessary. If this condition cannot be achieved, special field trim modifications, and/or additional urethane caulking Not By Chief may be required.

Optional urethane caulk at JT end. (NOT BY CHIEF)

4 1/4" TO EDGE OF WINDOW JAMB

Optional urethane caulk behind JT (NOT BY CHIEF)

SILL JAMB TRIM (JT) NOTCH AND SLIT WALL PANEL FOR EXTENSION OF TRIM. (TYP.) ** #12-14 X 1 1/4" (12" C.C.) (TYP.) WALL PANEL

JAMB TRIM (JTA)

FLAT OF

EDGE OF JAMB HEAD TRIM

Optional Urethane caulk around 2" panel slit and under JTA (NOT BY CHIEF) (TYP.)

END OF JAMB TRIM (JTA)

TRIM DETAIL AT CORNERS

WALL PANEL SLIT

(Window not Shown)

ZEE GIRT #12-14 X 1" PANCAKE HEAD (36" C.C.) (TYP.)

BL

OPENING WIDTH

1/8" X 3/8" BLIND RIVET, (18" C.C.) WITH LINER COVER TRIM (LCT) 3/16" BULBTITE RIVET (12" C.C.) (SIDE ONLY) 1/8" X 3/8" BLIND RIVET (7'-0" C.C.) (TYP.) **#12-14 X 1 1/4" (12" C.C.)

1/8" X 3/8" BLIND RIVET (7'-0" C.C.)

LINER COVER TRIM (LCT1)

**#12-14 X 1 1/4" (12" C.C.)

CEE HEADER

INSIDE CLOSURE

2 1 4 "

* 1 4 "

1/8" X 3/8" BLIND RIVET, 18" C.C. WITH COVER TRIM (LCT)

HEADER TRIM (HTT) WINDOW BY CHIEF URETHANE CAULK (NOT BY CHIEF)

LINER COVER TRIM (LCT2)

JAMB

LINER COVER TRIM (LCT1)

SPECIAL PLATE. REFER TO FRAMING PLANS FOR PIECE MARK (PL) LINER COVER TRIM (LCT2)

BL

1/8" X 3/8" BLIND RIVET, 18" C.C. WITH COVER TRIM (LCT) * Provide air gap of 1/4" min. at bottom of panel to avoid corrosion.

OPENING

URETHANE CAULK (NOT BY CHIEF) 3/16" BULBTITE RIVET (12" C.C.) (SIDE ONLY)

WALL PANEL

SILL JAMB TRIM (JT) URETHANE CAULK (NOT BY CHIEF)

JAMB TRIM (JTA) 1/4-14 X 7/8" (12" C.C.)

CUT RIB AS NEEDED

INSIDE CLOSURE **#12-14 X 1 1/4" (12" C.C.)

GIRT/SILL

Optional urethane caulk behind JT (NOT BY CHIEF)

SHEETING SUPPORT (SSP)

1/8" x 3/8" BLIND RIVET (7'-0" C.C.)

WALL PANEL (TYP.)

CHIEF WINDOW HEADER AND SILL

FRAMED OPENING DETAILS AT JAMB