Wall Panel and Trim
AP Window by Chief
AP Panel - Window by Chief
Installation Steps: 1. Install Wrap Plate, if applicable. 2. Liner Cover Trim(LCT), if applicable. Use with Liner/Backer. Refer to Liner or Partition Panel Drawings. 4. Window 5. Sill Jamb Trim (JT), slit and fold up at jamb. 6. Header Trim (HTT). 7. Sheeting Support (SSP) 8. Notch and slit wall panel. 6. Place wall panel over trims with foam inside closure full width of header and sill. 7. Jamb Trim (JTA) Notes: · Drill Ø1/8" holes for Blind Rivets. · Rivets spaced at 7'-0" C.C. are temporary fasteners. · ** #12-14 X 1-1/4", Blanket Insulation <=4" thickness. · ** #12-14 X 2", Blanket Insulation >4" thickness.
Head Trim (HTT) lapped 4 1/4" min. past edge of window jamb. Flush with end of Jamb Trim (JTA).
INSIDE CLOSURE Optional urethane caulk at HTT end. (NOT BY CHIEF)
HEADER TRIM (HTT)
2 1/4" X 1/4" PANEL NOTCH
SHEETING SUPPORT (SSP)
2" PANEL SLIT
WALL PANEL
Optional urethane caulk at panel slit and notch. Caulk under JTA. (NOT BY CHIEF) (TYP.)
JAMB TRIM (JTA)
LINER COVER TRIMS
2" SLIT
2" X 1/4" NOTCH
For best weathertightness performance, JTA/SSP and Head Trim assembly should land in flat of panel. Layout, verify, and consider field locating framed opening as necessary. If this condition cannot be achieved, special field trim modifications, and/or additional urethane caulking Not By Chief may be required.
Optional urethane caulk at JT end. (NOT BY CHIEF)
4 1/4" TO EDGE OF WINDOW JAMB
Optional urethane caulk behind JT (NOT BY CHIEF)
SILL JAMB TRIM (JT) NOTCH AND SLIT WALL PANEL FOR EXTENSION OF TRIM. (TYP.) ** #12-14 X 1 1/4" (12" C.C.) (TYP.) WALL PANEL
JAMB TRIM (JTA)
FLAT OF
EDGE OF JAMB HEAD TRIM
Optional Urethane caulk around 2" panel slit and under JTA (NOT BY CHIEF) (TYP.)
END OF JAMB TRIM (JTA)
TRIM DETAIL AT CORNERS
WALL PANEL SLIT
(Window not Shown)
ZEE GIRT #12-14 X 1" PANCAKE HEAD (36" C.C.) (TYP.)
BL
OPENING WIDTH
1/8" X 3/8" BLIND RIVET, (18" C.C.) WITH LINER COVER TRIM (LCT) 3/16" BULBTITE RIVET (12" C.C.) (SIDE ONLY) 1/8" X 3/8" BLIND RIVET (7'-0" C.C.) (TYP.) **#12-14 X 1 1/4" (12" C.C.)
1/8" X 3/8" BLIND RIVET (7'-0" C.C.)
LINER COVER TRIM (LCT1)
**#12-14 X 1 1/4" (12" C.C.)
CEE HEADER
INSIDE CLOSURE
2 1 4 "
* 1 4 "
1/8" X 3/8" BLIND RIVET, 18" C.C. WITH COVER TRIM (LCT)
HEADER TRIM (HTT) WINDOW BY CHIEF URETHANE CAULK (NOT BY CHIEF)
LINER COVER TRIM (LCT2)
JAMB
LINER COVER TRIM (LCT1)
SPECIAL PLATE. REFER TO FRAMING PLANS FOR PIECE MARK (PL) LINER COVER TRIM (LCT2)
BL
1/8" X 3/8" BLIND RIVET, 18" C.C. WITH COVER TRIM (LCT) * Provide air gap of 1/4" min. at bottom of panel to avoid corrosion.
OPENING
URETHANE CAULK (NOT BY CHIEF) 3/16" BULBTITE RIVET (12" C.C.) (SIDE ONLY)
WALL PANEL
SILL JAMB TRIM (JT) URETHANE CAULK (NOT BY CHIEF)
JAMB TRIM (JTA) 1/4-14 X 7/8" (12" C.C.)
CUT RIB AS NEEDED
INSIDE CLOSURE **#12-14 X 1 1/4" (12" C.C.)
GIRT/SILL
Optional urethane caulk behind JT (NOT BY CHIEF)
SHEETING SUPPORT (SSP)
1/8" x 3/8" BLIND RIVET (7'-0" C.C.)
WALL PANEL (TYP.)
CHIEF WINDOW HEADER AND SILL
FRAMED OPENING DETAILS AT JAMB
Made with FlippingBook - professional solution for displaying marketing and sales documents online