Wall Panel and Trim
AP Window by Chief
AP Panel - Window by Chief
#12-14 X 1" PANCAKE HEAD (36" C.C.) (TYP.) **#12-14 X 1 1/4" (12" C.C.) INSIDE CLOSURE WALL PANEL HEADER TRIM WITH TROUGH (HTT)
Notes: ·
ZEE GIRT
Drill Ø1/8" holes for Blind Rivets. Drill Ø3/16" holes for Bulbtite Rivets.
BL
·
· Rivets spaced at 7'-0" C.C. are temporary fasteners. · ** #12-14 X 1-1/4", Blanket Insulation <=4" thickness. · ** #12-14 X 2", Blanket Insulation >4" thickness. · LCT1 or LCT2 used with Liner/Backer. Refer to Liner or Partition Panel Dwg.
4 1/4"
1/8" X 3/8" BLIND RIVET (7'-0" C.C.)
1
4 "
HEADER TRIM WITH TROUGH (HTT)
1/8" X 3/8" BLIND RIVET (7'-0" C.C.) (TYP.)
NOTCH WALL PANEL FOR EXTENSION OF TRIM.
OPENING HEIGHT
SPECIAL PLATE. REFER TO FRAMING PLANS FOR PIECE MARK (PL)
JAMB TRIM (JTA)
LINER COVER TRIM (LCT2)
JAMB TRIM (JT)
Provide air gap of 1/4" min. at bottom of panel to avoid corrosion. 1 4 "
WINDOW BY CHIEF
LINER COVER TRIM (LCT1)
4 1/4"
CEE HEADER
CHIEF WINDOW HEADER TRIM DETAILS
TRIM DETAIL AT CORNER
1/8" X 3/8" BLIND RIVET (7'-0" C.C.)
SPECIAL PLATE. REFER TO FRAMING PLANS FOR PIECE MARK (PL)
BL
JAMB
WINDOW BY CHIEF
LINER COVER TRIM (LCT1)
LINER COVER TRIM (LCT2)
OPENING WIDTH
2 1/4"
LINER COVER TRIM (LCT1)
JAMB TRIM (JT)
OPENING HEIGHT
LINER COVER TRIM (LCT2)
**#12-14 X 1 1/4" (12" C.C.)
INSIDE CLOSURE **#12-14 X 1 1/4" (12" C.C.) WALL PANEL
BL
WINDOW BY CHIEF
GIRT #12-14 X 1" PANCAKE HEAD (36" C.C.) (TYP.) 1/8" X 3/8" BLIND RIVET (7'-0" C.C.) (TYP.)
WALL PANEL
URETHANE CAULK (NOT BY CHIEF) 3/16" BULBTITE RIVET (12" C.C.) (SIDE ONLY) SHEETING SUPPORT (SSP)
1/4-14 X 7/8" (12" C.C.)
JAMB TRIM (JTA)
OPENING HEIGHT
CEE SILL
CHIEF WINDOW JAMB TRIM DETAILS
CHIEF WINDOW SILL TRIM DETAILS
Made with FlippingBook - professional solution for displaying marketing and sales documents online