AP Window or 4-Sided Opening w Jamb Trim–JT
AP Panel - Window Not by Chief or 4-Sided Opening with Jamb Trim – JT
Notes: ·
LINER COVER TRIM (LCT1)
Drill Ø1/8" holes for Blind Rivets.
· Rivets spaced at 7'-0" C.C. are temporary fasteners. · ** #12-14 X 1-1/4", Blanket Insulation <=4" thickness. · ** #12-14 X 2", Blanket Insulation >4" thickness. · LCT1 or LCT2 used with Liner/Backer. Refer to Liner or Partition Panel Dwg.
1/8" X 3/8" BLIND RIVET, 7'-0" C.C. WITH LINER COVER TRIM (LCT) JAMB
OPENING WIDTH
**#12-14 X 1 1/4" (12" C.C.)
OPENING WIDTH
2 1/4"
BL
JAMB
LINER COVER TRIM (LCT2)
1/8" X 3/8" BLIND RIVET (7'-0" C.C.)
JAMB TRIM (JTA) SHEETING SUPPORT (SSP) LINER COVER TRIM (LCT2)
JAMB TRIM (JTA)
BL
FRAMED OPENING DETAILS AT JAMB
WALL PANEL 1/4-14 X 7/8" (12" C.C.)
GIRT
1/8" X 3/8" BLIND RIVET (7'-0" C.C.) #12-14 X 1" PANCAKE HEAD (36" C.C.) (TYP.)
BL
TRIM DETAILS AT JAMB
1/8" X 3/8" BLIND RIVET, 7'-0" C.C. WITH LINER COVER TRIM (LCT)
BL
**#12-14 X 1 1/4" (12" C.C.) INSIDE CLOSURE
ZEE GIRT
HEADER TRIM WITH TROUGH (HTT) SPECIAL PLATE. REFER TO FRAMING PLANS FOR PIECE MARK (PL) LINER COVER TRIM (LCT2)
LINER COVER TRIM (LCT1)
SPECIAL PLATE. REFER TO FRAMING PLANS FOR PIECE MARK (PL)
WALL PANEL
OPENING
1
4 "
JAMB TRIM (JT)
HEADER TRIM WITH TROUGH (HTT) LINER COVER TRIM (LCT2)
1/8" x 3/8" BLIND RIVET (7'-0" C.C.)
1
4 "
OPENING HEIGHT
GIRT/SILL
Provide air gap of 1/4" min. at bottom of panel to avoid corrosion.
CEE HEADER
OPENING DETAILS AT HEADER AND SILL
TRIM DETAILS AT HEADER
4 1/4"
BL
LINER COVER TRIM (LCT2)
JAMB TRIM (JT)
OPENING HEIGHT
HEADER TRIM WITH TROUGH (HTT)
NOTCH WALL PANEL FOR EXTENSION OF TRIM.
INSIDE CLOSURE **#12-14 X 1 1/4" (12 "C.C.)
JAMB TRIM (JTA)
JAMB TRIM (JT)
WALL PANEL
4 1/4"
GIRT/SILL
TRIM (JT) DETAILS AT SILL
TRIM DETAIL AT CORNER