Wall Panel and Trim
AP Window or 4-Sided Opening w Sill Flashing–WFS
AP Panel - Window or 4-Sided Opening with Sill Flashing – WFS
Notes: ·
Drill Ø1/8" holes for Blind Rivets.
· Rivets spaced at 7'-0" C.C. are temporary fasteners. · ** #12-14 X 1-1/4", Blanket Insulation <=4" thickness. · ** #12-14 X 2", Blanket Insulation >4" thickness. · LCT1 or LCT2 used with Liner/Backer. Refer to Liner or Partition Panel Dwg.
LINER COVER TRIM (LCT1)
1/8" X 3/8" BLIND RIVET, 7'-0" C.C. WITH LINER COVER TRIM (LCT)
OPENING WIDTH
**#12-14 X 1 1/4" (12" C.C.)
OPENING WIDTH
2 1/4"
JAMB
LINER COVER TRIM (LCT2)
JAMB
BL
1/8" X 3/8" BLIND RIVET (7'-0" C.C.) (TYP.)
LINER COVER TRIM (LCT2)
JAMB TRIM (JTA)
FRAMED OPENING DETAILS AT JAMB
JAMB TRIM (JTA) SHEETING SUPPORT (SSP)
BL
WALL PANEL 1/4-14 X 7/8" (12" C.C.)
HEADER TRIM WITH TROUGH (HTT) SPECIAL PLATE. REFER TO FRAMING PLANS FOR PIECE MARK (PL) LINER COVER TRIM (LCT2) 1/8" X 3/8" BLIND RIVET (7'-0" C.C.) (TYP.) GIRT #12-14 X 1" PANCAKE HEAD (36" C.C.) (TYP.)
BL
TRIM DETAILS AT JAMB
1/8" X 3/8" BLIND RIVET (3'-0" C.C.) (TYP.)
Provide air gap of 1/4" min. at bottom of panel to avoid corrosion.
BL
**#12-14 X 1 1/4" (12" C.C.) INSIDE CLOSURE WALL PANEL
ZEE GIRT
LINER COVER TRIM (LCT1)
SPECIAL PLATE. REFER TO FRAMING PLANS FOR PIECE MARK (PL)
OPENING
1
4 "
SILL TRIM FLASHING (WFS)
1
4 "
HEADER TRIM WITH TROUGH (HTT) LINER COVER TRIM (LCT2)
GIRT/SILL
OPENING HEIGHT
CEE HEADER
OPENING DETAILS AT HEADER AND SILL
TRIM DETAILS AT HEADER
4 1/4"
BL
LINER COVER TRIM (LCT1)
1/8" X 3/8" BLIND RIVET (12" C.C.)
SILL TRIM FLASHING (WFS)
OPENING HEIGHT
HEADER TRIM (HT)
NOTCH WALL PANEL FOR EXTENSION OF TRIM.
1/4-14 X 7/8" (12" C.C.)
INSIDE CLOSURE **#12-14 X 1 1/4" (12 "C.C.)
JAMB TRIM (JTA)
SILL TRIM FLASHING (WFS)
WALL PANEL
4 1/4"
GIRT/SILL
TRIM DETAIL AT SILL (WFS)
TRIM DETAIL AT CORNER