Height Change - Steel Uphill Cut on Back-to-Back Cee Post to Top of Height Change Rafter-Left Uphill Cut on Cee Corner Post to Top of Height Change Frame Column-Left Uphill Cut on Endwall Post to Top of Height Rafter-Left Uphill Cut on Outset Corner Post to Top of Height Change Frame Column-Left Uphill Cut on Rotated Corner Post to Top of Height Change Frame Column-Left Uphill Height Change Endwall Rafter Bracketed to Taller Endwall Post-Left Uphill Height Change Endwall Rafter Bracketed to Taller Inset Sidewall Corner Post-Left Uphill Height Change Endwall Rafter Bracketed to Taller Outset Sidewall Corner Post-Left Uphill Height Change Endwall Rafter Bracketed to Taller Rotated Corner Post-Left Height Change - Purlins CS Height Change at High Side w Eave Strut and Taller Backup Panel CS Height Change at High Side w Out Eave Strut and Taller Backup Panel Back Up Panel at Height Change - STC-MSC Roof STC-MSC Gable Field Bend Vertical Leg - Taller Backup Panel and Thermal Spacer STC-MSC Gable Lead - Taller Backup Panel and Thermal Spacer STC-MSC Gable Tail - Taller Backup Panel and Thermal Spacer STC-MSC Gable Tail Special Term Trim - Taller Backup Panel and Thermal Spacer STC-MSC High Side - Taller Backup Panel and Thermal Spacer Back Up Panel at Height Change - MVF-MVP Roof MVF-MVP Height Change at Gable Lead End w Taller Backup Panel and Thermal Spacer MVF-MVP Height Change at Gable Tail End w Taller Backup Panel and Thermal Spacer MVF-MVP Height Change at High Side w Taller Backup Panel and Thermal Spacer MVF-MVP Height Change w Cut Roof Panel at Gable Lead End - Taller Backup Panel and Thermal Spacer Multi-Gutter Multi-Gutter CS Same Height Existing Building Multi-Gutter CS Sidewall between Same Height Buildings Multi-Gutter CS Taller Building Multi-Gutter CS Taller Existing Building Multi-Gutter MVF-MVP Same Height Existing Building Multi-Gutter MVF-MVP Same Height Buildings Multi-Gutter MVF-MVP Taller Building Inset Gable Height Change w Zee Purlin-Building on Left Outset Gable Height Change w Zee Purlin-Building on Left Back Up Panel at Height Change - CS Roof CS Height Change at Gable w Taller Backup Panel
Multi-Gutter MVF-MVP Taller Existing Building Multi-Gutter STC-MSC Same Height Buildings Multi-Gutter STC-MSC Same Height Existing Building Multi-Gutter STC-MSC Taller Building
Table of Contents
Multi-Gutter STC-MSC Taller Existing Building Multi-Gutter Downspouts Multi-Gutter End Cap and Splice Parapet Eave Steel
Parapet Steel at Bypass High Side Standard Corner Post w Back to Back Cee Post and Support Girt Parapet Steel at Bypass High Side Standard Corner Post w Single Cee Post and Support Girt Parapet Steel at Bypass High Side w Back to Back Cee Post and Support Girt Parapet Steel at Bypass High Side w Single Cee Post and Support Girt Parapet Steel at Bypass High Side w Wide Flange Post and Support Girt Parapet Steel at Bypass Low Side w Wide Flange Post Parapet Steel at Flush High Side Rotated Corner Post w Wide Flange Post and Support Girt Parapet Steel at Flush High Side w Wide Flange Post and Support Girt Parapet Steel at Flush Low Side w Wide Flange Post Parapet Steel at Inset High Side w Wide Flange Post and Support Girt Parapet Steel at Inset Low Side w Wide Flange Post Parapet Gable Steel
Parapet at Bypass Endwall w Wide Flange Post Parapet at Flush Endwall w Wide Flange Post Parapet - CS Roof Parapet at Endwall w CS
Parapet at High Side w CS - Support Girt Parapet at Low Side w CS - Multi-gutter Parapet - CS Roof w Nichiha Panel Extended Façade CS Roof Panel w Multi-gutter and Nichiha Panel Not by Chief Extended Façade CS Roof Panel w Multi-gutter and Nichiha Panel-Cap Trim Not by Chief
Parapet at Endwall w CS Roof Panel and Nichiha Panel Not by Chief Parapet at High Side w CS Roof Panel and Nichiha Panel Not by Chief Parapet at Low Side w Multi-gutter and Nichiha Panel Not by Chief Parapet - STC-MSC Roof - Eave Parapet at Low Side w STC-MSC w Multi-gutter Parapet at High Side w STC-MSC w Support Girt and Thermal Spacer Parapet - STC-MSC w Nichiha Panel - Eave Parapet at Low Side with STC-MSC Roof Panel-Multi-gutter and Nichiha Panel Not by Chief Parapet at High Side with STC-MSC Roof Panel-Support Girt Thermal Spacer and Nichiha Panel Not by Chief Parapet - STC-MSC Roof - Gable
Parapet at Endwall w STC-MSC Gable Lead End w Thermal Spacer Parapet at Endwall w STC-MSC Gable Tail End w Thermal Spacer Parapet at Endwall w STC-MSC Gable End w Field Bend Vertical Leg and Thermal Spacer Parapet - STC-MSC w Nichiha Panel - Gable Parapet at Endwall w STC-MSC Gable Lead End Thermal Spacer and Nichiha Panel NBC
Table of Contents
Parapet at Endwall w STC-MSC Gable Tail End Thermal Spacer and Nichiha Panel NBC Parapet at Endwall w STC-MSC Gable w Field Bend Leg Thermal Spacer and Nichiha Panel NBC Inset-Outset Fascia Inset-Outset Girt Facade-Through Column Inset-Outset Girt Facade-Left Corner Wide Openings and Doors Higher Power Hydraulic Door at Inset Sidewall Wide Endwall Opening w Header Beam (Preferred) Wide Opening at Inset Endwall (Alternate) Bi-Fold Doors Bi-fold Door Cross Section
Bi-fold Door Jamb w AP Panel Bi-fold Door Jamb w CS Panel Doors at Brittle Material OHD or 3-Sided Opening in Brittle Material Wall - Jambs to FF w DST Walkdoor KD in Brittle Material Wall - Jambs to top of wall Walkdoor KD-Other in Brittle Material Wall - Jambs to FF w DST Walkdoor PA-SF in Brittle Material Wall - No Subframe w Jambs w DST
Walkdoor PA-SF in Brittle Material Wall - Subframe to FF w DST Walkdoor PA-SF in Brittle Material Wall - Subframe to top of wall Boxed in Below Eave Canopy Boxed in Below Eave Canopy Steel - Beam to Flush Column w Horizontal Soffit Purlins Boxed in Below Eave Canopy Steel - Canopy End Cee Section Support to Blocking at Building Line
Boxed in Below Eave Canopy w CS Roof Panel at Building Line and FSP Soffit Boxed in Below Eave Canopy w CS Roof Panel at Canopy End and FSP Soffit Boxed in Below Eave Canopy w CS Roof Panel-Eave Gutter and FSP Soffit
Boxed in Below Eave Canopy w CS End Panel at Inside Corner Boxed in Below Eave Canopy w AP End Panel at Inside Corner Transverse Expansion - Girts
Girt to Inset Col w 6-8 Flange at Trans Exp Girt to Inset Col w 10 Flange at Trans Exp Girt to Bypass Col w 6-8 Flange at Trans Exp Girt to Bypass Col w 10 Flange at Trans Exp
Transverse Expansion - Eave Strut at Purlin Roof Eave Strut to Col w 6-8 Flange and CS Roof Trans Exp Eave Strut to Col w 10 Flange and CS Roof Trans Exp
Eave Strut to Col w 6-8 flange and MVF-MVP Roof Trans Exp w Thermal Spacer Eave Strut to Col w 10 flange and MVF-MVP Roof Trans Exp w Thermal Spacer Eave Strut to Col w 6-8 Flange and MVF-MVP Roof Trans Exp wo Thermal Spacer Eave Strut to Col w 10 Flange and MVF-MVP Roof Trans Exp wo Thermal Spacer
Table of Contents
Eave Strut to Col w 6-8 Flange and STC-MSC Roof Trans Exp w Thermal Spacer Eave Strut to Col w 10 Flange and STC-MSC Roof Trans Exp w Thermal Spacer Eave Strut to Col w 6-8 Flange and STC-MSC Roof Trans Exp wo Thermal Spacer Eave Strut to Col w 10 Flange and STC-MSC Roof Trans Exp wo Thermal Spacer Transverse Expansion - Purlins Z-Purlin to Rafter 6-8 Flange and STC-MSC Roof Trans Exp Z-Purlin to Rafter 10 Flange and STC-MSC Roof Trans Exp Z-Purlin to Rafter 6-8 Flange and MVF-MVP Roof Trans Exp Z-Purlin to Rafter 10 Flange and MVF-MVP Roof Trans Exp Transverse Expansion - Eave Strut at Bypass Column with Roof Joists Eave Strut to Bypass Col w 6-8 flange Joist and MVF-MVP Roof Trans Exp w Thermal Spacer Eave Strut to Bypass Col w 10 flange Joist and MVF-MVP Roof Trans Exp w Thermal Spacer Eave Strut to Bypass Col w 6-8 Flange Joist and MVF-MVP Roof Trans Exp wo Thermal Spacer Eave Strut to Bypass Col w 10 Flange Joist and MVF-MVP Roof Trans Exp wo Thermal Spacer Eave Strut to Bypass Col w 6-8 Flange Joist and STC-MSC Roof Trans Exp w T-Spcr Eave Strut to Bypass Col w 10 Flange Joist and STC-MSC Roof Trans Exp w T-Spcr Eave Strut to Bypass Col w 6-8 Flange Joist and STC-MSC Roof Trans Exp wo T-Spcr Eave Strut to Bypass Col w 10 Flange Joist and STC-MSC Roof Trans Exp wo T-Spcr Transverse Expansion - Eave Strut at Inset Column with Roof Joists Eave Strut to Inset Col w 6-8 flange Joist and MVF-MVP Roof Trans Exp w Thermal Spacer Eave Strut to Inset Col w 10 flange Joist and MVF-MVP Roof Trans Exp w Thermal Spacer Eave Strut to Inset Col w 6-8 Flange Joist and MVF-MVP Roof Trans Exp wo Thermal Spacer Eave Strut to Inset Col w 10 Flange Joist and MVF-MVP Roof Trans Exp wo Thermal Spacer Eave Strut to Inset Col w 6-8 Flange Joist and STC-MSC Roof Trans Exp w T-Spcr Eave Strut to Inset Col w 10 Flange Joist and STC-MSC Roof Trans Exp w T-Spcr Eave Strut to Inset Col w 6-8 Flange Joist and STC-MSC Roof Trans Exp wo T-Spcr Eave Strut to Inset Col w 10 Flange Joist and STC-MSC Roof Trans Exp wo T-Spcr Transverse Expansion - Roof Joists Z-Purlin to Rafter 6-8 Flange and CS Roof Trans Exp Z-Purlin to Rafter 10 Flange and CS Roof Trans Exp
Short Span Joist to Rafter w 6-8 Flange Trans Exp Short Span Joist to Rafter with 10 Flange Trans Exp Long Span Joist to Rafter w 6-8 Flange Trans Exp Long Span Joist to Rafter w 10 Flange Trans Exp Transverse Expansion - Walls CS Wall Panel Expansion w J Trim Inset AP Wall Panel Expansion w J Trim Inset CS Wall Panel Expansion w J Trim Bypass AP Wall Panel Expansion w J Trim Bypass Transverse Expansion - Roof with Purlins
Table of Contents
CS Trans Exp Purlin CS Trans Exp Trim Plug Conn
MVF-MVP Exp 2.5 inch GAP 2 inch TOTAL SLIDE w T-SPCR MVF-MVP Exp 2.5 inch GAP 2 inch TOTAL SLIDE wo T-SPCR MVF-MVP Exp 3.5 inch GAP 2 inch TOTAL SLIDE w T-SPCR MVF-MVP Exp 3.5 inch GAP 2 inch TOTAL SLIDE wo T-SPCR
MVF-MVP Exp ACROSS ROOF CAP DETAIL 1 MVF-MVP Exp ACROSS ROOF CAP DETAIL 2 MVF-MVP Exp TRIM PLUG CONN FLOW LEFT
STC-MSC Exp 2.5 inch GAP 2 inch TOTAL SLIDE w T-SPCR STC-MSC Exp 2.5 inch GAP 2 inch TOTAL SLIDE wo T-SPCR STC-MSC Exp 3.5 inch GAP 2 inch TOTAL SLIDE w T-SPCR STC-MSC Exp 3.5 inch GAP 2 inch TOTAL SLIDE wo T-SPCR
STC-MSC Exp ACROSS ROOF CAP detail 1 STC-MSC Exp ACROSS ROOF CAP detail 2 STC-MSC Exp TRIM PLUG CONNECTION Transverse Expansion - Roof with Joists
MVF-MVP Exp Joist 2 inch TOTAL SLIDE w T-SPCR Joist MVF-MVP Exp Joist 2 inch TOTAL SLIDE wo T-SPCR Joist MVF-MVP Exp Joist ACROSS ROOF CAP DETAIL 1 MVF-MVP Exp Joist ACROSS ROOF CAP DETAIL 2 MVF-MVP Exp Joist TRIM PLUG CONN FLOW LEFT STC-MSC Exp Joist 2 inch TOTAL SLIDE w T-SPCR Joist STC-MSC Exp Joist 2 inch TOTAL SLIDE wo T-SPCR Joist STC-MSC Exp Joist ACROSS ROOF CAP detail 1 STC-MSC Exp Joist ACROSS ROOF CAP detail 2 STC-MSC Exp Joist TRIM PLUG CONNECTION Transverse Expansion - Existing Building by Chief MVF-MVP EXIST BLDG by CHIEF ROOF CAP DETAIL 1 MVF-MVP EXIST BLDG by CHIEF ROOF CAP DETAIL 2 MVF-MVP LT EXIST BLDG by CHIEF TRIM PLUG CONN STC-MSC EXIST BLDG by CHIEF 3 inch GAP w T-SPCR STC-MSC EXIST BLDG by CHIEF at ROOF CAP detail 1 STC-MSC EXIST BLDG by CHIEF at ROOF CAP detail 2 STC-MSC EXIST BLDG by CHIEF TRIM PLUG CONNECTION Transverse Expansion - Existing Building NOT by Chief CS ROOF PANEL to EXIST BLDG NBC CS ROOF PANEL to EXIST BLDG NBC TRIM PLUG CONN MVF-MVP EXIST BLDG by CHIEF Exist Lead w T MVF-MVP EXIST BLDG by CHIEF Exist Tail w T
Table of Contents
MVF-MVP EXIST BLDG NBC LEAD w T-SPCR MVF-MVP EXIST BLDG NBC TAIL w T-SPCR MVF-MVP EXIST BLDG NBC ROOF CAP MVF-MVP EXIST LT BLDG NBC TRIM PLUG CONN STC-MSC EXIST BLDG NBC w T-SPCR STC-MSC EXIST BLDG NBC ROOF CAP STC-MSC EXIST BLDG NBC TRIM PLUG CONN CS Roof Longitudinal Expansion Joint with Purlins CS panel 1'-0 Stepped Roof Detail w Straight DS CS panel 1'-2 Stepped Roof Detail w Straight DS CS panel Short Step Roof Detail w Straight DS Smart Canopy Smart Canopy-STC-MSC Eave Smart Canopy-STC-MSC Eave-CS-AP Ceiling Liner Smart Canopy-STC-MSC Eave-FSP Ceiling Liner Smart Canopy-STC-MSC Gable Lead-Height Change
Smart Canopy-STC-MSC Gable Lead-Height Change-AP Ceiling Liner Smart Canopy-STC-MSC Gable Lead-Height Change-CS Ceiling Liner Smart Canopy-STC-MSC Gable Lead-Height Change-Exist Bldg Smart Canopy-STC-MSC Gable Lead-Height Change-Exist Bldg-AP Ceiling Liner Smart Canopy-STC-MSC Gable Lead-Height Change-Exist Bldg-CS Ceiling Liner Smart Canopy-STC-MSC Gable Lead-Height Change-Exist Bldg-FSP Ceiling Liner Smart Canopy-STC-MSC Gable Lead-Height Change-FSP Ceiling Liner Smart Canopy-STC-MSC Gable Tail
Smart Canopy-STC-MSC Gable Tail-AP Ceiling Liner Smart Canopy-STC-MSC Gable Tail-CS Ceiling Liner Smart Canopy-STC-MSC Gable Tail-FSP Ceiling Liner Smart Canopy-STC-MSC Ridge Smart Canopy-STC-MSC Ridge-CS-AP Ceiling Liner Smart Canopy-STC-MSC Ridge-FSP Ceiling Liner Smart Canopy-MVF-MVP Eave Smart Canopy-MVF-MVP Eave-CS-AP Ceiling Liner Smart Canopy-MVF-MVP Eave-FSP Ceiling Liner Smart Canopy-MVF-MVP Gable Lead-Height Change
Smart Canopy-MVF-MVP Gable Lead-Height Change-AP Ceiling Liner Smart Canopy-MVF-MVP Gable Lead-Height Change-CS Ceiling Liner Smart Canopy-MVF-MVP Gable Lead-Height Change-Exist Bldg Smart Canopy-MVF-MVP Gable Lead-Height Change-Exist Bldg-AP Ceiling Liner Smart Canopy-MVF-MVP Gable Lead-Height Change-Exist Bldg-CS Ceiling Liner Smart Canopy-MVF-MVP Gable Lead-Height Change-Exist Bldg-FSP Ceiling Liner
Table of Contents
Smart Canopy-MVF-MVP Gable Lead-Height Change-FSP Ceiling Liner Smart Canopy-MVF-MVP Gable Tail
Smart Canopy-MVF-MVP Gable Tail-AP Ceiling Liner Smart Canopy-MVF-MVP Gable Tail-CS Ceiling Liner Smart Canopy-MVF-MVP Gable Tail-FSP Ceiling Liner Smart Canopy-MVF-MVP Ridge Smart Canopy-MVF-MVP Ridge-CS-AP Ceiling Liner Smart Canopy-MVF-MVP Ridge-FSP Ceiling Liner Smart Canopy Support Tube Column Splice
Height Change - Steel
Height Change Steel
Uphill Cut on Back-to-Back Cee Post to Top of Height Change Rafter-Left
BACK TO BACK ENDWALL POST
RAFTER BEAM (4) 1/2" X 1 1/4" BOLTS
Uphill Cut on Cee Corner Post to Top of Height Change Frame Column-Left
1
BL
CORNER POST
EAVE STRUT
(2) 5/8" X 1 1/2" BOLTS W/ (2) 5/8" HARD WASHERS ON C-SECTION SIDE
(2) 1/2" X 1 1/4" BOLTS
FRAME COLUMN
Uphill Cut on Endwall Post to Top of Height Rafter-Left
1
CL
WIDE FLANGE ENDWALL POST
(4) 1/2" X 1 1/4" BOLTS
RAFTER BEAM
Uphill Cut on Outset Corner Post to Top of Height Change Frame Column-Left
1
BL
EAVE STRUT (4) 1/2" X 1 1/4" BOLTS CORNER POST (2) 5/8" X 1 1/2" BOLTS W/ (2) 5/8" HARD WASHERS ON C-SECTION SIDE
FRAME COLUMN
Uphill Cut on Rotated Corner Post to Top of Height Change Frame Column-Left
1
BL
CORNER POST
EAVE STRUT
(2) 5/8" X 1 1/2" BOLTS W/ (2) 5/8" HARD WASHERS ON C-SECTION SIDE
(4) 1/2" X 1 1/4" BOLTS
FRAME COLUMN
Uphill Height Change Endwall Rafter Bracketed to Taller Endwall Post-Left
1
CL
ENDWALL POST
ENDWALL RAFTER BEAM
(4) 1/2" X 1 1/4" BOLTS
Uphill Height Change Endwall Rafter Bracketed to Taller Inset Sidewall Corner Post-Left
1
BL
1"
CORNER POST EAVE STRUT (2) 5/8" X 1 1/2" BOLTS W/ (2) 5/8" HARD WASHERS ON C-SECTION SIDE (4) 1/2" X 1 1/4" BOLTS ENDWALL RAFTER BEAM
Uphill Height Change Endwall Rafter Bracketed to Taller Outset Sidewall Corner Post-Left
1
BL
CORNER POST
EAVE STRUT
(2) 5/8" X 1 1/2" BOLTS W/ (2) 5/8" HARD WASHERS ON C-SECTION SIDE
(4) 1/2" X 1 1/4" BOLTS
ENDWALL RAFTER BEAM
Uphill Height Change Endwall Rafter Bracketed to Taller Rotated Corner Post-Left
1
BL
CORNER POST EAVE STRUT
(2) 5/8" X 1 1/2" BOLTS W/ (2) 5/8" HARD WASHERS ON C-SECTION SIDE
(4) 1/2" X 1 1/4" BOLTS
ENDWALL RAFTER BEAM
Height Change - Purlins
Height Change Purlins
Inset Gable Height Change w Zee Purlin-Building on Left
Outset Gable Height Change w Zee Purlin-Building on Left
1
3 3 4 "
HEIGHT CHANGE ANGLE (A-20-H)
BL
4"
#12-14 X 1" PANCAKE HEAD (2 EACH PURLIN)
PURLIN (2) 1/2" X 1 1/4" BOLTS RAFTER BEAM
Back Up Panel at Height Change - CS Roof
Back Up Panel at Height Change CSRoof
CS Height Change at Gable w Taller Backup Panel
DOUBLE BEAD TAPE MASTIC 1/4-14 X 1 1/4" WT (12" C.C.) HEIGHT CHANGE TRIM (RHT) INSIDE CLOSURE w/ TAPE MASTIC TOP & BOTTOM 1/4-14 x 1 1/4" WT (6" C.C. for CS PANEL) (12" C.C.for AP PANEL) HEIGHT CHANGE ANGLE (A-20-H) *BACK-UP PANEL
BL
PURLIN
CS ROOF PANEL
1
4 "
#12-14 X 1 1/4" (2 EACH PURLIN) (WALL COLOR)
1"
* FIELD CUT BOTTOM OF BACK-UP PANELS TO MATCH ROOF SLOPE. PROVIDE AIR GAP OF 1/4" MIN. AT BOTTOM OF PANEL TO AVOID CORROSION.
TAPE MASTIC SENT FOR BACK-UP PANEL SIDE LAPS. WARRANTY FASTENERS SENT FOR BACK-UP PANEL.
CS Height Change at High Side w Eave Strut and Taller Backup Panel
TAPE MASTIC SENT FOR BACK-UP PANEL SIDE LAPS. WARRANTY FASTENERS SENT FOR BACK-UP PANEL.
1
1/4-14 X 1 1/4" WT (6" C.C. for CS PANEL) (12" C.C. for AP PANEL) GIRT BACK-UP PANEL
BL
1/4-14 X 7/8" WT (12" C.C.) HEIGHT CHANGE TRIM (LHTC) INSIDE CLOSURE w/ TAPE MASTIC TOP & BOTTOM OUTSIDE CLOSURE (2" X 3')
1 4 " Provide air gap of 1/4" min. at bottom of panel to avoid corrosion.
1 1
2 "
CS ROOF PANEL
2 ROWS DOUBLE BEAD MASTIC TOP & BOTTOM OF OUTSIDE CLSOURE
1/4-14 X 1 1/4" WT (6" C.C.) EAVE STRUT
CS Height Change at High Side w Out Eave Strut and Taller Backup Panel
TAPE MASTIC SENT FOR BACK-UP PANEL SIDE LAPS. WARRANTY FASTENERS SENT FOR BACK-UP PANEL.
1
1/4-14 X 1 1/4" WT (6" C.C. for CS PANEL) (12" C.C. for AP PANEL) GIRT BACK-UP PANEL
BL
1/4-14 X 7/8" WT (12" C.C.) HEIGHT CHANGE TRIM (LHTC) INSIDE CLOSURE w/ TAPE MASTIC TOP & BOTTOM OUTSIDE CLOSURE (2" X 3')
1 4 " Provide air gap of 1/4" min. at bottom of panel to avoid corrosion.
1 1
2 "
CS ROOF PANEL
2 ROWS DOUBLE BEAD MASTIC TOP & BOTTOM OF OUTSIDE CLSOURE
1/4-14 X 1 1/4" WT (6" C.C.) EAVE STRUT
Back Up Panel at Height Change - STC-MSC Roof
Back Up Panel at Height Change STC-MSC Roof
STC-MSC Gable Field Bend Vertical Leg - Taller Backup Panel and Thermal Spacer
** FIELD CUT BOTTOM OF BACK-UP PANELS TO MATCH ROOF SLOPE. PROVIDE AIR GAP OF 1/4" MIN. AT BOTTOM OF PANEL TO AVOID CORROSION.
SIKA 511 CAULK IN LOCKFORM OF HEIGHT CHANGE TRIM TOP (BEFORE ASSEMBLING)
INSIDE CLOSURE w/ TAPE MASTIC TOP & BOTTOM
1
INSIDE CLOSURE
**BACK-UP PANEL
HEIGHT CHANGE TRIM TOP (GHMTF) TRI-BEAD TAPE SEALER SIKA 511 CAULK IN LOCKFORM OF HEIGHT CHANGE TRIM TOP (BEFORE ASSEMBLING) (SEE INSET DETAIL)
BL
1/4-14 X 1 1/4" WT (6" C.C. for CS PANEL) (12" C.C. for AP PANEL)
RAKE SUPPORT (A-20-T)
1/4-14 X 1 1/4" WT (12" C.C.) STC/MSC ROOF PANEL (FIELD FORM 3" VERTICAL LEG TO FIT FINAL DIMENSION)
* It is important that fasteners are installed through the center of the slotted holes of the rake support. TAPE MASTIC SENT FOR BACK-UP PANEL SIDE LAPS. WARRANTY FASTENERS SENT FOR BACK-UP PANEL.
THERMAL SPACER
(NOT BY CHIEF)
1
4 "
HEIGHT CHANGE ANGLE (A-20-H)
HEIGHT CHANGE TRIM BOTTOM (GHMBF)
2"
1/4-14 X 1 1/4" SHOULDER (24" C.C.)*
#12-14 X 1" PANCAKE HEAD (2 EACH PURLIN) PURLIN
STC-MSC Gable Lead - Taller Backup Panel and Thermal Spacer
SIKA 511 CAULK IN LOCKFORM OF HEIGHT CHANGE TRIM TOP (BEFORE ASSEMBLING)
** FIELD CUT BOTTOM OF BACK-UP PANELS TO MATCH ROOF SLOPE. PROVIDE AIR GAP OF 1/4" MIN. AT BOTTOM OF PANEL TO AVOID CORROSION.
INSIDE CLOSURE w/ TAPE MASTIC TOP & BOTTOM HEIGHT CHANGE TRIM TOP (GHMTF) TRI-BEAD TAPE SEALER
1
BL
**BACK-UP PANEL
SIKA 511 CAULK IN LOCKFORM OF HEIGHT CHANGE TRIM TOP (BEFORE ASSEMBLY) (SEE INSET DETAIL)
1/4-14 X 1 1/4" SHOULDER (24" C.C.)* RAKE SUPPORT (A-20-T) HEIGHT CHANGE ANGLE (A-20-H) 1/4-14 X 1 1/4" WT (6" C.C. for CS PANEL) (12" C.C. for AP PANEL)
1/4-14 X 1 1/4" WT (12" C.C.) STC/MSC ROOF PANEL THERMAL SPACER
(NOT BY CHIEF)
* It is important that fasteners are installed through the center of the slotted holes of the rake support. TAPE MASTIC SENT FOR BACK-UP PANEL SIDE LAPS. WARRANTY FASTENERS SENT FOR BACK-UP PANEL.
PURLIN
1
4 "
HEIGHT CHANGE TRIM BOTTOM (GHMBF)
2"
#12-14 X 1" PANCAKE HEAD (2 EACH PURLIN)
STC-MSC Gable Tail - Taller Backup Panel and Thermal Spacer
** FIELD CUT BOTTOM OF BACK-UP PANELS TO MATCH ROOF SLOPE. PROVIDE AIR GAP OF 1/4" MIN. AT BOTTOM OF PANEL TO AVOID CORROSION.
SIKA 511 CAULK IN LOCKFORM OF HEIGHT CHANGE TRIM TOP (BEFORE ASSEMBLING)
HEIGHT CHANGE TRIM TOP (GHMTF) INSIDE CLOSURE w/TAPE MASTIC TOP & BOTTOM
1
**BACK-UP PANEL 1/4-14 X 1 1/4" WT
BL
SIKA 511 CAULK IN LOCKFORM OF HEIGHT CHANGE TRIM TOP (BEFORE ASSEMBLING) (SEE INSET DETAIL) TRI-BEAD TAPE SEALER
(6" C.C. for CS PANEL) (12" C.C. for AP PANEL)
RAKE SUPPORT (A-20-T)
THERMAL SPACER STC/MSC ROOF PANEL 1/4-14 X 1 1/4" WT (12" C.C.)
* It is important that fasteners are installed through the center of the slotted holes of the rake support. TAPE MASTIC SENT FOR BACK-UP PANEL SIDE LAPS. WARRANTY FASTENERS SENT FOR BACK-UP PANEL.
(NOT BY CHIEF)
1
4 "
#12-14 X 1" PANCAKE HEAD (2 EACH PURLIN) PURLIN HEIGHT CHANGE TRIM BOTTOM (GHMBF) 1/4-14 X 1 1/4" SHOULDER (24" C.C.)*
HEIGHT CHANGE ANGLE (A-20-H)
2"
STC-MSC Gable Tail Special Term Trim - Taller Backup Panel and Thermal Spacer
* FIELD CUT BOTTOM OF BACK-UP PANELS TO MATCH ROOF SLOPE. PROVIDE AIR GAP OF 1/4" MIN. AT BOTTOM OF PANEL TO AVOID CORROSION.
SIKA 511 CAULK IN LOCKFORM OF SPECIAL TRIM TOP (SPT- ) (BEFORE ASSEMBLING)
INSIDE CLOSURE w/ TAPE MASTIC TOP & BOTTOM SPECIAL TRIM (SPT- ) TRI-BEAD TAPE MASTIC
BL
*BACK-UP PANEL
SEKA 511 CAULK IN LOCKFORM OF SPECIAL TRIM TOP (SPT- ) (BEFORE ASSEMBLING) (SEE INSET DETAIL) 1/4-14 X 1 1/4" WT (12" C.C. AND FASTEN THROUGH CLIP)
#12-14 X 1" PANCAKE HEAD (2 EACH PURLIN) 1/4-14 X 1 1/4" WT (6" C.C. for CS PANEL) (12" C.C. for AP PANEL)
THERMAL SPACER STC/MSC ROOF PANEL
1
4 "
HEIGHT CHANGE ANGLE (A-20-H)
(NOT BY CHIEF)
HEIGHT CHANGE TRIM BOTTOM (GHMBF)
Tape mastic sent for back-up panel side laps. Warranty fasteners sent for back-up panel.
PANEL CLIP
PURLIN
STC-MSC High Side - Taller Backup Panel and Thermal Spacer
1/4-14 X 1 1/4" WT (6" C.C. for CS PANEL) (12" C.C. for AP PANEL) INSIDE CLOSURE w/ TAPE MASTIC TOP & BOTTOM
BL
**TRI-BEAD TAPE MASTIC OUTSIDE CLOSURE 1/4-14 X 1 1/4" WT (9 PER PANEL) TRI-BEAD TAPE MASTIC *1/4-14 X 7/8" WT HEIGHT CHANGE TRIM (LHET)
HEIGHT CHANGE GIRT BACK-UP PANEL
Provide air gap of 1/4" min. at bottom of panel to avoid corrosion.
1
4 "
Tape mastic sent for back-up panel side laps. Warranty fasteners sent for back-up panel.
* For screw spacing refer to High Eave Height Change Trim detail in the MSC/STC Roof Panel Erection Manual. ** 24" STC - Pre-Cut Tri-Bead Tape Mastic. 24" MSC - Tri-Bead Tape Mastic from roll. 18" MSC/STC - Tri-Bead Tape Mastic from roll.
STC/MSC ROOF PANEL
PANEL CLIP W/ FASTENERS (SEE ROOF PANEL PLAN)
(NOT BY CHIEF)
THERMAL SPACER PURLIN BACK-UP PLATE
4"
8"
Back Up Panel at Height Change - MVF-MVP Roof
Back Up Panel at Height Change MVF-MVP Roof
MVF-MVP Height Change at Gable Lead End w Taller Backup Panel and Thermal Spacer
* Field cut bottom of back-up panels to match roof slope. Provide air gap of 1/4" min. at bottom of panel to avoid corrosion.
HEIGHT CHANGE TRIM TOP (GHVT)
Tape Mastic sent for back-up panel side laps. Warranty fasteners sent for back-up panel.
MVF/MVP ROOF PANEL DOUBLE BEAD TAPE MASTIC 1/4-14 X 7/8" WT (6" C.C.)** TAPE MASTIC HEIGHT CHANGE TRIM BOTTOM (GHVB) (2) #12-14 X 1 1/4" (EACH CLIP) WALL COLOR
*BACK-UP PANEL INSIDE CLOSURE w/ TAPE MASTIC TOP & BOTTOM 1/4-14 X 1 1/4" WT
BL
(6" C.C. for CS PANEL) (12" C.C. for AP PANEL)
(NOT BY CHIEF)
THERMAL SPACER
1
4 "
PANEL CLIP w/FASTENERS (REFER TO ROOF PANEL PLAN)
PANEL CLIP RAKE ANGLE (A-20-L) #12-14 X 1 1/4" (2 EACH PURLIN) (WALL COLOR)
1"
(2) #12-14 X 1 1/4" (WALL COLOR)
**NOTE: This fastener must not hit the purlin.
PURLIN
MVF-MVP Height Change at Gable Tail End w Taller Backup Panel and Thermal Spacer
* Field cut bottom of back-up panels to match roof slope. Provide air gap of 1/4" min. at bottom of panel to avoid corrosion.
DOUBLE BEAD TAPE MASTIC 1/4-14 X 1 1/4" WT (6" C.C.)** DOUBLE BEAD TAPE MASTIC HEIGHT CHANGE TRIM BOTTOM (GHVB) HEIGHT CHANGE TRIM TOP (GHVT) (2) #12-14 X 1 1/4" (EACH CLIP) WALL COLOR ROOF PANEL CUT BACK DIM. CLIP LOCATION FROM B L TAPE MASTIC
Tape Mastic sent for back-up panel side laps. Warranty fasteners sent for back-up panel.
BL
*BACK-UP PANEL INSIDE CLOSURE w/ TAPE MASTIC TOP & BOTTOM 1/4-14 X 1 1/4" WT
2 1 4 "
1 1 2 "
(6" C.C. for CS PANEL) (12" C.C. for AP PANEL)
MVF/MVP ROOF PANEL RAKE ANGLE (A-20-B)
PANEL CLIP w/FASTENERS (REFER TO ROOF PANEL PLAN)
1
4 "
RAKE ANGLE (A-20-L) #12-14 X 1 1/4" (2 EACH PURLIN) (WALL COLOR)
(NOT BY CHIEF)
THERMAL SPACER
#12-14 X 1 1/4" (WALL COLOR)
**NOTE: This fastener must not hit the purlin.
PURLIN
MVF-MVP Height Change at High Side w Taller Backup Panel and Thermal Spacer
EXPANSION TRIM (LHET) 1/4-14 X 1 1/4" WT (6" C.C. for CS PANEL) (12" C.C. for AP PANEL) INSIDE CLOSURE w/ TAPE MASTIC TOP & BOTTOM
BL
*1/4-14 X 7/8" WT
GIRT BACK-UP PANEL
DOUBLE BEAD TAPE MASTIC
RIDGE CLOSURE
PANEL CLIP w/ FASTENERS (REFER TO ROOF PANEL PLAN)
MVF/MVP ROOF PANEL
1 4 " Provide air gap of 1/4" min. at bottom of panel to avoid corrosion.
3"
PURLIN DOUBLE BEAD TAPE MASTIC 1/4-14 X 7/8" WT (7 PER PANEL) THERMAL SPACER
(NOT BY CHIEF)
Tape Mastic sent for back-up panel side laps. Warranty fasteners sent for back-up panel.
* For screw spacing refer to High Side Height Change detail in the MVF/MVP Roof Panel Erection manual.
MVF-MVP Height Change w Cut Roof Panel at Gable Lead End - Taller Backup Panel and Thermal Spacer
* Field cut bottom of back-up panels to match roof slope. Provide air gap of 1/4" min. at bottom of panel to avoid corrosion.
ROOF PANEL CUT BACK DIM. CLIP LOCATION FROM B
L
HEIGHT CHANGE TRIM BOTTOM (GHVB) HEIGHT CHANGE TRIM TOP (GHVT)
Tape Mastic sent for back-up panel side laps. Warranty fasteners sent for back-up panel.
BL
TAPE MASTIC
*BACK-UP PANEL INSIDE CLOSURE w/TAPE MASTIC TOP & BOTTOM 1/4-14 X 1 1/4" WT
DOUBLE BEAD TAPE MASTIC 1/4-14 X 1 1/4" WT (6" C.C.)** DOUBLE BEAD TAPE MASTIC (2) #12-14 X 1 1/4" (EACH CLIP) WALL COLOR
2 1 4 "
1 1 2 "
(6" C.C. for CS PANEL) (12" C.C. for AP PANEL)
MVF/MVP ROOF PANEL RAKE ANGLE (A-20-B)
PANEL CLIP w/FASTENERS (REFER TO ROOF PANEL PLAN)
1
4 "
PANEL CLIP RAKE ANGLE (A-20-L)
THERMAL SPACER
(NOT BY CHIEF)
#12-14 X 1 1/4" (2 EACH PURLIN) (WALL COLOR)
PURLIN
(2) #12-14 X 1 1/4" (WALL COLOR)
**NOTE: This fastener must not hit the purlin.
Multi-Gutter
Multi-Gutter
Multi-Gutter CS Same Height Existing Building
1
1
L EXIST. B
BL
* MULTI-GUTTER (MG- ) EXISTING ROOF PANEL (NOT BY CHIEF)
INSIDE CLOSURE WITH MASTIC TOP AND BOTTOM
CS ROOF PANEL EAVE STRUT
DRAFTING: INVESTIGATE THE ERECTABILITY OF THIS MULTI-GUTTER FOR YOUR PROJECT
1/4-14 X 1 1/4" WT (4" C.C.)
FRAME COLUMN
EXISTING BUILDING
BUILDING LINE TO BUILDING LINE
* Refer to the Multi-Gutter Endcap and Splice detail for installation This run of multi-gutter uses (2) MGEC- as endcaps
Multi-Gutter CS Sidewall between Same Height Buildings
1
1
BL
BL
MULTI-GUTTER (MG- )
INSIDE CLOSURE WITH MASTIC TOP AND BOTTOM
CS ROOF PANEL EAVE STRUT
1/4-14 X 1 1/4" WT (4" C.C.)
FRAME COLUMN
BUILDING LINE TO BUILDING LINE
* Refer to the Multi-Gutter Endcap and Splice detail for installation This run of Multi-Gutter uses (2) MGEC- as endcaps
Multi-Gutter CS Taller Building
1
1
BL
BL
WALL PANEL
GIRT
#12-14 X 1 1/4" (6" C.C. for CS PANEL) (12" C.C. for AP PANEL) INSIDE CLOSURE w/ TAPE MASTIC TOP & BOTTOM
INSIDE CLOSURE WITH MASTIC TOP AND BOTTOM
CS ROOF PANEL EAVE STRUT
1/4-14 X 1 1/4" WT (4" C.C.)
FRAME COLUMN
* MULTI-GUTTER (MG- )
BUILDING LINE TO BUILDING LINE
* Refer to the Multi-Gutter Endcap and Splice detail for installation This run of multi-gutter uses (2) MGEC- as endcaps
Multi-Gutter CS Taller Existing Building
1
1
L EXIST. B
BL
COUNTER FLASHING, FASTENER AND CAULKING (NOT BY CHIEF)
* MULTI-GUTTER (MG- )
INSIDE CLOSURE WITH MASTIC TOP AND BOTTOM
CS ROOF PANEL EAVE STRUT
1/4-14 X 1 1/4" WT (4" C.C.)
EXISTING BUILDING
FRAME COLUMN
BUILDING LINE TO BUILDING LINE
* Refer to the Multi-Gutter Endcap and Splice detail for installation This run of multi-gutter uses (2) MGEC- as endcaps
Multi-Gutter MVF-MVP Same Height Existing Building
1
1
1/4-14 X 1 1/4" WT (4 PER PANEL)
L EXIST. B
BL
EXISTING ROOF PANEL (NOT BY CHIEF)
"PIG TAIL" TAPE MASTIC (BETWEEN PANELS)
DOUBLE BEAD TAPE MASTIC MVF/MVP ROOF PANEL
DRAFTING: INVESTIGATE THE ERECTABILITY OF THIS MULTI-GUTTER FOR YOUR PROJECT
EAVE STRUT
FRAME COLUMN
* MULTI-GUTTER (MG- )
EXISTING BUILDING
BUILDING LINE TO BUILDING LINE
* Refer to the Multi-Gutter Endcap and Splice detail for installation This run of multi-gutter uses (2) MGEC- as end caps.
Multi-Gutter MVF-MVP Same Height Buildings
1
1
1/4-14 X 1 1/4" WT (4 PER PANEL)
BL
BL
"PIG TAIL" TAPE MASTIC (BETWEEN PANELS)
DOUBLE BEAD TAPE MASTIC MVF/MVP ROOF PANEL
EAVE STRUT
FRAME COLUMN
* MULTI-GUTTER (MG- )
BUILDING LINE TO BUILDING LINE
* Refer to the Multi-Gutter Endcap and Splice detail for installation This run of multi-gutter uses (2) MGEC- as end caps.
Multi-Gutter MVF-MVP Taller Building
1
1
BL
BL
#12-14 X 1 1/4" (6" C.C. for CS PANEL) (12" C.C. for AP PANEL) INSIDE CLOSURE w/ TAPE MASTIC TOP & BOTTOM
WALL PANEL
1/4-14 X 1 1/4" WT (4 PER PANEL)
GIRT
"PIG TAIL" TAPE MASTIC (BETWEEN PANELS)
DOUBLE BEAD TAPE MASTIC MVF/MVP ROOF PANEL
EAVE STRUT
* MULTI-GUTTER (MG- ) FRAME COLUMN
BUILDING LINE TO BUILDING LINE
* Refer to the Multi-Gutter Endcap and Splice detail for installation This run of multi-gutter uses (2) MGEC- as end caps.
Multi-Gutter MVF-MVP Taller Existing Building
1
1
L EXIST. B
BL
COUNTER FLASHING, FASTENER AND CAULKING (NOT BY CHIEF)
1/4-14 X 1 1/4" WT (4 PER PANEL)
"PIG TAIL" TAPE MASTIC (BETWEEN PANELS)
DOUBLE BEAD TAPE MASTIC MVF/MVP ROOF PANEL
EAVE STRUT
EXISTING BUILDING
* MULTI-GUTTER (MG- ) FRAME COLUMN
BUILDING LINE TO BUILDING LINE
* Refer to the Multi-Gutter Endcap and Splice detail for installation This run of multi-gutter uses (2) MGEC- as end caps.
Multi-Gutter STC-MSC Same Height Buildings
1
1
METAL INSIDE CLOSURE TRI-BEAD TAPE SEALER 1/4-14 X 1 1/4" WT PANEL (8 PER PANEL)
BL
BL
EAVE STRUT STC/MSC ROOF PANEL TRI-BEAD TAPE SEALER
1/4-14 X 1" (2) PER CLOSURE
FRAME COLUMN
* MULTI-GUTTER (MG- )
BUILDING LINE TO BUILDING LINE
* Refer to the Multi-Gutter Endcap and Splice detail for installation This run of multi-gutter uses (2) MGEC- as end caps.
Multi-Gutter STC-MSC Same Height Existing Building
1
1
METAL INSIDE CLOSURE TRI-BEAD TAPE SEALER 1/4-14 X 1 1/4" WT PANEL (8 PER PANEL)
L EXIST. B
BL
EXISTING ROOF PANEL (NOT BY CHIEF)
1/4-14 X 1" (2) PER CLOSURE EAVE STRUT STC/MSC ROOF PANEL TRI-BEAD TAPE SEALER
DRAFTING: INVESTIGATE THE ERECTABILITY OF THIS MULTI-GUTTER FOR YOUR PROJECT
FRAME COLUMN
* MULTI-GUTTER (MG- )
EXISTING BUILDING
BUILDING LINE TO BUILDING LINE
* Refer to the Multi-Gutter Endcap and Splice detail for installation This run of multi-gutter uses (2) MGEC- as end caps.
Multi-Gutter STC-MSC Taller Building
1
1
TRI-BEAD TAPE SEALER 1/4-14 X 1 1/4" WT PANEL (8 PER PANEL) INSIDE CLOSURE w/ TAPE MASTIC TOP & BOTTOM #12-14 X 1 1/4" (6" C.C. for CS PANEL) (12" C.C. for AP PANEL)
BL
BL
WALL PANEL
GIRT
STC/MSC ROOF PANEL METAL INSIDE CLOSURE
EAVE STRUT
TRI-BEAD TAPE SEALER
1/4-14 X 1" (2) PER CLOSURE
FRAME COLUMN
* MULTI-GUTTER (MG- )
BUILDING LINE TO BUILDING LINE
* Refer to the Multi-Gutter Endcap and Splice detail for installation This run of multi-gutter uses (2) MGEC- as end caps.
Multi-Gutter STC-MSC Taller Existing Building
1
1
L EXIST. B
BL
COUNTER FLASHING, FASTENER AND CAULKING (NOT BY CHIEF) METAL INSIDE CLOSURE TRI-BEAD TAPE SEALER 1/4-14 X 1 1/4" WT PANEL (8 PER PANEL)
STC/MSC ROOF PANEL
EAVE STRUT
1/4-14 X 1" (2) PER CLOSURE TRI-BEAD TAPE SEALER
EXISTING BUILDING
FRAME COLUMN
* MULTI-GUTTER (MG- )
BUILDING LINE TO BUILDING LINE
* Refer to the Multi-Gutter Endcap and Splice detail for installation This run of multi-gutter uses (2) MGEC- as end caps.
Multi-Gutter Downspouts
Reference notes: ·
NOTE: CHIEF BUILDINGS recommends that the multi-gutter be lined with material suitable for weather related exposure. CHIEF BUILDINGS primer is for temporary protection only.
All sealant is SikaLastomer ® -511.
· Seal gutter insert to gutter with a 3/8" bead of sealant around flanges of insert. Hand tool into place upon installation to minimize damning effect. · Field cut holes in multi-gutter for downspouts
DOWNSPOUT INSERT
MULTI-GUTTER
SEALANT
CUT LINE
(3) 1/8" X 3/8" BLIND RIVET DOWNSPOUT
DOWNSPOUT BY CHIEF TO MULTI-GUTTER
Multi-Gutter End Cap and Splice
NOTE: CHIEF BUILDINGS recommends that the multi-gutter be lined with material suitable for weather related exposure. CHIEF BUILDINGS primer is for temporary protection only.
MULTI-GUTTER (MG)
END CAP (MGEC)
BUTT WELD
MULTI-GUTTER (MG)
FILLET WELD
MULTI-GUTTER END CAP AND SPLICE
Parapet Eave Steel
Parapet Eave Steel
Parapet Steel at Bypass High Side Standard Corner Post w Back to Back Cee Post and Support Girt
1
1 1 2 "
BL
BACK-TO-BACK C-SECTION PARAPET POST
XXX'-X"
HEIGHT CHANGE GIRT
PARAPET GIRT (4) 1/2" X 1 1/4" BOLTS
EAVE STRUT (2) 5/8" X 1 1/2" BOLTS W/ (2) 5/8" HARDENED WASHERS ON C-SECTION SIDE
XXX'-X"
CONTINUOUS PURLIN (2) 1/2" X 1 1/4" BOLTS
(4) 1/2" X 1 1/4" BOLTS (TYP)
GIRT
XXX'-X"
(4) 3/4" X 2" BOLTS W/ (4) 3/4" HARDENED WASHERS ON C-SECTION SIDE
(6) 1/2" X 1 1/4" BOLTS ENDWALL RAFTER BEAM
CORNER POST
Parapet Steel at Bypass High Side Standard Corner Post w Single Cee Post and Support Girt
1
1 1 2 "
BL
SINGLE C-SECTION PARAPET POST
XXX'-X"
XBC-84
PARAPET GIRT (4) 1/2" X 1 1/4" BOLTS
EAVE STRUT (2) 5/8" X 1 1/2" BOLTS W/ (2) 5/8" HARDENED WASHERS ON C-SECTION SIDE HEIGHT CHANGE GIRT
XXX'-X"
CONTINUOUS PURLIN (2) 1/2" X 1 1/4" BOLTS
(4) 1/2" X 1 1/4" BOLTS (TYP)
GIRT
XXX'-X"
XBC-3 (TYP)
(6) 1/2" X 1 1/4" BOLTS ENDWALL RAFTER BEAM
(4) 3/4" X 2" BOLTS W/ (4) 3/4" HARDENED WASHERS ON C-SECTION SIDE
CORNER POST
Parapet Steel at Bypass High Side w Back to Back Cee Post and Support Girt
1
1 1 2 "
BL
XXX'-X"
(4) 1/2" X 1 1/4" BOLTS (4) 1/2" X 1 1/4" BOLTS (TYP)
HEIGHT CHANGE GIRT PARAPET GIRT
XXX'-X"
EAVE STRUT (4) 5/8" X__" BOLTS W/(4) 5/8" HARD WASHERS AT C-SECTION SIDE
BACK-TO-BACK C-SECTION PARAPET POST
CONTINUOUS PURLIN (6) 1/2" X 1 1/4" BOLTS
HIGH SIDE FRAME COLUMN
GIRT
XXX'-X"
(4) 3/4" X 2" BOLTS W/ (4) 3/4" HARDENED WASHERS ON C-SECTION SIDE
Parapet Steel at Bypass High Side w Single Cee Post and Support Girt
1
1 1 2 "
BL
XXX'-X"
PARAPET GIRT
(6) 1/2" X 1 1/4" BOLTS
SINGLE C-SECTION PARAPET POST
(1) XBC-84 EACH SIDE
HEIGHT CHANGE GIRT
XXX'-X"
EAVE STRUT (4) 5/8" X__" BOLTS W/(4) 5/8" HARD WASHERS AT C-SECTION SIDE
(6) 1/2" X 1 1/4" BOLTS (TYP)
CONTINUOUS PURLIN (6) 1/2" X 1 1/4" BOLTS
XBC-3 THIS SIDE, XBC-84 OTHER SIDE (TYP)
HIGH SIDE FRAME COLUMN
GIRT
XXX'-X"
(4) 3/4" X 2" BOLTS W/ (4) 3/4" HARDENED WASHERS ON C-SECTION SIDE
Parapet Steel at Bypass High Side w Wide Flange Post and Support Girt
1
1 1 2 "
BL
XXX'-X"
(6) 1/2" X 1 1/4" BOLTS
PARAPET GIRT PARAPET POST
(1) XBC-85 EACH SIDE
HEIGHT CHANGE GIRT
XXX'-X"
EAVE STRUT (4) 5/8" X__" BOLTS W/(4) 5/8" HARD WASHERS AT C-SECTION SIDE
(6) 1/2" X 1 1/4" BOLTS (TYP)
CONTINUOUS PURLIN (6) 1/2" X 1 1/4" BOLTS
(1) XBC-74 EACH SIDE, (TYP)
HIGH SIDE FRAME COLUMN
GIRT
XXX'-X"
(4) __" X __" BOLTS
Parapet Steel at Bypass Low Side w Wide Flange Post
1
1 1 2 "
BL
PARAPET GIRT
XXX'-X"
(1) XBC-85 EACH SIDE
(6) 1/2" X 1 1/4" BOLTS
PARAPET POST
NOTE: CHIEF BUILDINGS RECOMMENDS THAT THE MULTI-GUTTER BE LINED WITH MATERIAL SUITABLE FOR WEATHER RELATED EXPOSURE. CHIEF BUILDINGS PRIMER IS FOR TEMPORARY PROTECTION ONLY.
(6) 1/2" X 1 1/4" BOLTS
(1) XBC-74 EACH SIDE
EAVE STRUT (4) 5/8" X 1 1/2" BOLTS W/ (4) 5/8" HARD WASHERS AT C-SECTION SIDE
XXX'-X"
HEIGHT CHANGE GIRT MULTIGUTTER (MG-X)
(4) ___" x ___" BOLTS
FRAME COLUMN
Parapet Steel at Flush High Side Rotated Corner Post w Wide Flange Post and Support Girt
1
(4) 1/2" X 1 1/4" BOLTS
BL
1 1
2 "
XXX'-X"
PARAPET GIRT
XBC-85
PARAPET POST
(4) 1/2" X 1 1/4" BOLTS (TYP)
HEIGHT CHANGE GIRT
XXX'-X"
EAVE STRUT
CONTINUOUS PURLIN (6) 1/2" X 1 1/4" BOLTS
XBC-74 (TYP)
(4) __" X __" BOLTS
ENDWALL RAFTER
(2) 5/8" X 1 1/2" BOLTS W/ (2) 5/8" HARD WASHERS AT C-SECTION SIDE
XXX'-X"
(4) 1/2" X 1 1/4" BOLTS
CORNER POST
1'-2"
Parapet Steel at Flush High Side w Wide Flange Post and Support Girt
1
1 1 2 "
BL
XXX'-X"
PARAPET POST
(6) 1/2" X 1 1/4" BOLTS PARAPET GIRT (1) XBC-85 EACH SIDE
HEIGHT CHANGE GIRT
(1) XBC-74 EACH SIDE, (TYP)
(4) 5/8" X__" BOLTS W/(4) 5/8" HARD WASHERS AT C-SECTION SIDE EAVE STRUT
XXX'-X"
(6) 1/2" X 1 1/4" BOLTS
(6) 1/2" X 1 1/4" BOLTS PURLIN
(4) __" X __" BOLTS
HIGH SIDE FRAME COLUMN
(6) 1/2" X 1 1/4" BOLTS
XXX'-X"
GIRT
Parapet Steel at Flush Low Side w Wide Flange Post
1
1 1 2 "
PARAPET GIRT
BL
XXX'-X"
(1) XBC-85 EACH SIDE
(6) 1/2" X 1 1/4" BOLTS
PARAPET POST
NOTE: CHIEF BUILDINGS RECOMMENDS THAT THE MULTI-GUTTER BE LINED WITH MATERIAL SUITABLE FOR WEATHER RELATED EXPOSURE. CHIEF BUILDINGS PRIMER IS FOR TEMPORARY PROTECTION ONLY.
(6) 1/2" X 1 1/4" BOLTS
(1) XBC-74 EACH SIDE
EAVE STRUT (4) 5/8" X 1 1/2" BOLTS W/ (4) 5/8" HARD WASHERS AT C-SECTION SIDE
XXX'-X"
HEIGHT CHANGE GIRT MULTIGUTTER (MG-X)
(4) ___" x ___" BOLTS
FRAME COLUMN
Parapet Steel at Inset High Side w Wide Flange Post and Support Girt
1
1 1 2 "
BL
XXX'-X"
PARAPET POST
PARAPET GIRT (1) XBC-85 EACH SIDE
HEIGHT CHANGE GIRT
(1) XBC-74 EACH SIDE, (TYP)
(6) 1/2" X 1 1/4" BOLTS
(4) 5/8" X__" BOLTS W/ (4) 5/8" HARD WASHERS AT C-SECTION SIDE EAVE STRUT
XXX'-X"
(6) 1/2" X 1 1/4" BOLTS
(6) 1/2" X 1 1/4" BOLTS PURLIN
(4) __" X __" BOLTS
HIGH SIDE FRAME COLUMN
(6) 1/2" X 1 1/4" BOLTS
1"
XXX'-X"
GIRT
Parapet Steel at Inset Low Side w Wide Flange Post
1
1 1 2 "
BL
XXX'-X"
PARAPET GIRT
(1) XBC-85 EACH SIDE
(6) 1/2" X 1 1/4" BOLTS
PARAPET POST
NOTE: CHIEF BUILDINGS RECOMMENDS THAT THE MULTI-GUTTER BE LINED WITH MATERIAL SUITABLE FOR WEATHER RELATED EXPOSURE. CHIEF BUILDINGS PRIMER IS FOR TEMPORARY PROTECTION ONLY.
(6) 1/2" X 1 1/4" BOLTS
(1) XBC-74 EACH SIDE
EAVE STRUT (4) 5/8" X 1 1/2" BOLTS W/ (4) 5/8" HARD WASHERS AT C-SECTION SIDE
XXX'-X"
HEIGHT CHANGE GIRT MULTIGUTTER (MG-X) (4) ____" x ____" BOLTS
FRAME COLUMN
1"
Parapet Gable Steel
Parapet Gable Steel
Parapet at Bypass Endwall w Wide Flange Post
SEE ROOF FRAMING PLAN FOR ENDWALL RAFTER TO PURLIN FLANGE BRACE REQUIREMENTS.
1
1 1 2 "
BL
XXX'-X"
PARAPET GIRT
(1) XBC-85 EACH SIDE
PARAPET POST
(6) 1/2" X 1 1/4" BOLTS
PURLIN (2) 1/2" X 1 1/4" BOLTS
1'-0" or 1'-2"
1 4 "
ENDWALL RAFTER
GIRT
(6) 1/2" X 1 1/4" BOLTS
(4) 1/2" X 1 1/4" BOLTS
(4) __" X __" BOLTS
XXX'-X"
(1) XBC-74 EACH SIDE
ENDWALL POST
Parapet at Flush Endwall w Wide Flange Post
1
SEE ROOF FRAMING PLAN FOR ENDWALL RAFTER TO PURLIN FLANGE BRACE REQUIREMENTS.
1 1 2 "
BL
XXX'-X"
(6) 1/2" X 1 1/4" BOLTS
PARAPET GIRT
(1) XBC-85 EACH SIDE
GIRT (1) XBC-74 EACH SIDE
(6) 1/2" X 1 1/4" BOLTS
PURLIN (2) 1/2" X 1 1/4" BOLTS
1'-0" or 1'-2"
1 4 "
ENDWALL RAFTER
(4) 1/2" X 1 1/4" BOLTS
PARAPET/ ENDWALL POST
Parapet - CS Roof
Parapet CSRoof
Parapet at Endwall w CS
HORIZONTAL LEG OF PARAPET CAP TRIM
#12-14 X 1 1/4" (24" C.C.)
* NOTE: REFER TO ISOMETRIC PARAPET FACADE CAP TRIM SPLICE DETAIL FOR INSTALLATION
PARAPET TRIM CAP (PCT-X)
* PARAPET CLEAT (PCC-X)
BL
#12-14 X 1" PANCAKE HEAD (12" C.C.)
PARAPET GIRT
OUTSIDE CLOSURE 1/4-14 X 7/8" WT (12" C.C.) **BACK-UP PANEL
XXX'-X"
TAPE MASTIC SENT FOR BACK-UP PANEL SIDE LAPS. WARRANTY FASTENERS SENT FOR BACK-UP PANEL.
#12-14 X 1 1/4" (6" C.C. for CS PANEL) (12" C.C. for AP PANEL) OUTSIDE CLOSURE
CS ROOF PANEL DOUBLE BEAD TAPE MASTIC 1/4 - 14 X 1 1/4" WT (12" C.C.) HEIGHT CHANGE TRIM (RHT-X) INSIDE CLOSURE w/ TAPE MASTIC TOP & BOTTOM
PARAPET/WALL PANEL
1/4-14 X 1 1/4" WT (6" C.C.)
HEIGHT CHANGE ANGLE (A-20-H)
** FIELD CUT BOTTOM OF BACK-UP PANELS TO MATCH ROOF SLOPE. PROVIDE AIR GAP OF 1/4" MIN. AT BOTTOM OF PANEL TO AVOID CORROSION.
1
4 "
1"
1 4 "
#12 - 14 X 1 1/4" (2 EACH PURLIN) (WALL COLOR)
Parapet at High Side w CS - Support Girt
* NOTE: REFER TO ISOMETRIC PARAPET FACADE CAP TRIM SPLICE DETAIL FOR INSTALLATION
PARAPET GIRT PARAPET CAP TRIM (PCT-X) 1/4-14 X 1 1/4" WT (6" C.C.) OUTSIDE CLOSURE 1/4-14 X 7/8" WT (12" C.C.) Provide air gap of 1/4" min. at bottom of panel to avoid corrosion.
1
BL
* PARAPET CLEAT (PCC-X) #12-14 X 1 1/4" (24" C.C.)
TAPE MASTIC SENT FOR BACK-UP PANEL SIDE LAPS. WARRANTY FASTENERS SENT FOR BACK-UP PANEL.
XXX'-X"
BACKUP PANEL
INSIDE CLOSURE w/ TAPE MASTIC TOP & BOTTOM HEIGHT CHANGE TRIM (LHTC) 1/4-14 X 7/8" WT (12" C.C.) 1/4-14 X 1 1/4" WT (6" C.C.) OUTSIDE CLOSURE (2" X 3') 2 ROWS DOUBLE BEAD MASTIC TOP & BOTTOM OF OUTSIDE CLOSURE
#12-14 X 1" PANCAKE HEAD (12" C.C.)
#12-14 X 1 1/4" (6" C.C. for CS PANEL) (12" C.C. for AP PANEL) OUTSIDE CLOSURE
XXX'-X"
DRAFTING USE ONLY: REMOVE EAVE STRUT OR PURLIN W/CORRESPONDING FASTENER AS REQUIRED.
PARAPET/WALL PANEL
1
4 "
CS ROOF PANEL
1 1 2 "
HEIGHT CHANGE GIRT
1/4 -14 X 1 1/4" WT (6"C.C.)
1/4-14 X 1 1/4" WT (6" C.C.) PURLIN
EAVE STRUT
Parapet at Low Side w CS - Multi-gutter
* NOTE: REFER TO ISOMETRIC PARAPET FACADE CAP TRIM SPLICE DETAIL FOR INSTALLATION
1
#12-14 X 1 1/4" (24" C.C.)
INSIDE CLOSURE w/ TAPE MASTIC TOP & BOTTOM 1/4 -14 X 1 1/4" WT (6" C.C.) BACKUP PANEL 1/4 - 14 X 7/8" WT (12" C.C.) 1/4 -14 X 1 1/4" WT (6" C.C.) PARAPET GIRT OUTSIDE CLOSURE
PARAPET CAP TRIM (PCT-X) * PARAPET CLEAT (PCC-X)
BL
OUTSIDE CLOSURE
XXX'-X"
TAPE MASTIC SENT FOR BACK-UP PANEL SIDE LAPS. WARRANTY FASTENERS SENT FOR BACK-UP PANEL.
#12 - 14 X 1" PANCAKE HEAD (12"C.C)
PARAPET/WALL PANEL
INSIDE CLOSURE W/ MASTIC TOP & BOTTOM
XXX'-X"
GIRT #12-14 X 1 1/4" (12" C.C.) #12-14 X 1 1/4" (6" C.C. for CS PANEL) (12" C.C. for AP PANEL)
1/4 - 14 X 1 1/4" WT (4" C.C.) CS ROOF PANEL
** MULTI-GUTTER (MG-X) EAVE STRUT
** Refer to the Multi-Gutter Endcap and Splice detail for installation This run of multi-gutter uses (2) MGEC- as endcaps
Parapet - CS Roof w Nichiha Panel
Parapet CS Roof w Nichiha Panel
Extended Façade CS Roof Panel w Multi-gutter and Nichiha Panel Not by Chief
HORIZONTAL LEG OF FASCIA CAP TRIM
TAPE MASTIC SENT FOR BACK-UP PANEL SIDE LAPS. WARRANTY FASTENERS SENT FOR BACK-UP PANEL.
1
DRAFTING: DIMENSION HORIZ. LEG OF CAP TRIM. HAVE PM VERIFY DIM. WITH BLDR.
BL
X"
X'-X"
#12-14 X 1 1/4" (24" C.C.)
INSIDE CLOSURE w/ TAPE MASTIC TOP AND BOTTOM 1/4-14 X 1 1/4" WT (6" C.C.) BACKUP PANEL 1/4-14 X 7/8" WT (12" C.C.) 1/4-14 X 1 1/4" WT (6" C.C.) FACADE GIRT OUTSIDE CLOSURE
X
SPECIAL CAP TRIM (SPT-X)
** SPECIAL CLEAT (SPT-X)
XXX'-X"
#12-14 X 1 1/4" (CS - 6" C.C.)(AP - 12" C.C.) PANCAKE HEAD FASTENER (NOT BY CHIEF) (12"C.C) SPECIAL PURCHASED (IF BY CHIEF)
INSIDE CLOSURE W/ MASTIC TOP & BOTTOM
GIRT
XXX'-X"
1/4-14 X 1 1/4" WT (4" C.C.) CS ROOF PANEL
* _" NICHIHA PANEL (NOT BY CHIEF) #12-14 X 1 1/4" (6" C.C. for CS PANEL) (12" C.C. for AP PANEL)
#12-14 X 1 1/4" (CS - 6" C.C.)(AP - 12" C.C.)
EAVE STRUT
FASCIA PANEL
* _" NICHIHA PANEL (NOT BY CHIEF) WALL PANEL
*** MULTI-GUTTER (MG-X)
* NOTE: CONNECTION OF NICHIHA PANELS (NOT BY CHIEF), TO WALL PANEL IS NOT BY CHIEF.
** NOTE: REFER TO ISOMETRIC PARAPET FACADE CAP TRIM SPLICE DETAIL FOR INSTALLATION
*** Refer to the Multi-Gutter Endcap and Splice detail for installation This run of multi-gutter uses (2) MGEC- as endcaps
Extended Façade CS Roof Panel w Multi-gutter and Nichiha Panel-Cap Trim Not by Chief
DRAFTING: DIMENSION HORIZ. LEG OF CAP TRIM. HAVE PM VERIFY DIM. WITH BLDR.
HORIZONTAL LEG OF FASCIA CAP TRIM
1
* NOTE: CONNECTION OF NICHIHA PANELS (NOT BY CHIEF), TO WALL OR FASCIA PANEL IS NOT BY CHIEF.
TAPE MASTIC SENT FOR BACK-UP PANEL SIDE LAPS. WARRANTY FASTENERS SENT FOR BACK-UP PANEL.
BL
X'-X"
X"
CAP TRIM (NOT BY CHIEF) #12-14 X 1 1/4" (TYP) (6" C.C. for CS PANEL) (12" C.C. for AP PANEL)
X
FASTENER (12" C.C.) (NOT BY CHIEF) 1/4-14 X 1 1/4" WT (6" C.C.)
XXX'-X"
OUTSIDE CLOSURE
INSIDE CLOSURE w/ TAPE MASTIC TOP AND BOTTOM 1/4-14 X 1 1/4" WT (6" C.C.) BACKUP PANEL
FASTENER (NOT BY CHIEF) (12" C.C.)
SPECIAL PURCHASED (IF BY CHIEF)
INSIDE CLOSURE W/ MASTIC TOP & BOTTOM
FACADE GIRT
GIRT
XXX'-X"
1/4-14 X 1 1/4" WT (4" C.C.) CS ROOF PANEL
* _" NICHIHA PANEL (NOT BY CHIEF)
#12-14 X 1 1/4" (6" C.C. for CS PANEL) (12" C.C. for AP PANEL)
FASCIA PANEL
** MULTI-GUTTER (MG-X)
EAVE STRUT
* _" NICHIHA PANEL (NOT BY CHIEF) WALL PANEL
** Refer to the Multi-Gutter Endcap and Splice detail for installation This run of multi-gutter uses (2) MGEC- as endcaps
Made with FlippingBook flipbook maker